Allison Brookhart , Mahika Arora , Michael McCullagh , Ian D Wilson , Robert S Plumb , Johannes PC Vissers , Nikunj Tanna
{"title":"Understanding mobile phase buffer composition and chemical structure effects on electrospray ionization mass spectrometry response","authors":"Allison Brookhart , Mahika Arora , Michael McCullagh , Ian D Wilson , Robert S Plumb , Johannes PC Vissers , Nikunj Tanna","doi":"10.1016/j.chroma.2023.463966","DOIUrl":null,"url":null,"abstract":"<div><p>Mobile phase selection is of critical importance in liquid chromatography – mass spectrometry (LC-MS) based studies, since it affects retention, chromatographic selectivity, ionization, limits of detection and quantification, and linear dynamic range. Generalized LC-MS mobile phase selection criteria, suitable for a broad class of chemical compounds, do not exist thus far. Here we have performed a large-scale qualitative assessment of the effect of solvent composition used for reversed-phase LC separations on electrospray ionization (ESI) response for 240 small molecular weight drugs, representing various chemical compound classes. Of these 240 analytes 224 were detectable using ESI. The main chemical structural features affecting ESI response were found to all be surface area or surface charge-related. Mobile phase composition was found to be less differentiating, although for some compounds a pH effect was noted. Unsurprisingly, chemical structure was found to be the dominant factor for ESI response for the majority of the investigated analytes, representing about 85% of the replicating detectable complement of the sample data set. A weak correlation between ESI response and structure complexity was observed. Solvents based on isopropanol, and those containing phosphoric or di- and trifluoracetic acids, performed relatively poorly in terms of chromatographic or ESI response, whilst the best performing <em>‘generic’</em> LC solvents were based on methanol, acetonitrile using formic acid and ammonium acetate as buffer components, consistent with current practice in many laboratories.</p></div>","PeriodicalId":347,"journal":{"name":"Journal of Chromatography A","volume":"1696 ","pages":"Article 463966"},"PeriodicalIF":4.0000,"publicationDate":"2023-05-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chromatography A","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0021967323001929","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/4/5 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
Mobile phase selection is of critical importance in liquid chromatography – mass spectrometry (LC-MS) based studies, since it affects retention, chromatographic selectivity, ionization, limits of detection and quantification, and linear dynamic range. Generalized LC-MS mobile phase selection criteria, suitable for a broad class of chemical compounds, do not exist thus far. Here we have performed a large-scale qualitative assessment of the effect of solvent composition used for reversed-phase LC separations on electrospray ionization (ESI) response for 240 small molecular weight drugs, representing various chemical compound classes. Of these 240 analytes 224 were detectable using ESI. The main chemical structural features affecting ESI response were found to all be surface area or surface charge-related. Mobile phase composition was found to be less differentiating, although for some compounds a pH effect was noted. Unsurprisingly, chemical structure was found to be the dominant factor for ESI response for the majority of the investigated analytes, representing about 85% of the replicating detectable complement of the sample data set. A weak correlation between ESI response and structure complexity was observed. Solvents based on isopropanol, and those containing phosphoric or di- and trifluoracetic acids, performed relatively poorly in terms of chromatographic or ESI response, whilst the best performing ‘generic’ LC solvents were based on methanol, acetonitrile using formic acid and ammonium acetate as buffer components, consistent with current practice in many laboratories.
期刊介绍:
The Journal of Chromatography A provides a forum for the publication of original research and critical reviews on all aspects of fundamental and applied separation science. The scope of the journal includes chromatography and related techniques, electromigration techniques (e.g. electrophoresis, electrochromatography), hyphenated and other multi-dimensional techniques, sample preparation, and detection methods such as mass spectrometry. Contributions consist mainly of research papers dealing with the theory of separation methods, instrumental developments and analytical and preparative applications of general interest.