Effect of cement fill ratio in loosening of hip implants.

Biomatter Pub Date : 2012-04-01 DOI:10.4161/biom.20709
Elizabeth Gunn, Dinesh Gundapaneni, Tarun Goswami
{"title":"Effect of cement fill ratio in loosening of hip implants.","authors":"Elizabeth Gunn,&nbsp;Dinesh Gundapaneni,&nbsp;Tarun Goswami","doi":"10.4161/biom.20709","DOIUrl":null,"url":null,"abstract":"<p><p>Femoral loosening is one of the most prevalent causes of revision orthopedic surgeries. Cement mantle thickness has been directly correlated with femoral loosening. If the mantle is too thick, there is an increased risk of radiolucent lines and inconsistent densities. Also, the more bone that is reamed out during the procedure can lead to instability, especially if the quality of the bone is compromised due to osteoporosis. Too thin of a mantle can lead to a higher probability for cement fracture, loosening the prosthetic even further. This study has shown that there is an ideal thickness range between 2 to 5 mm that should be kept. From radiographic images one can measure the thickness of the cement mantle showing the loosening characteristics.</p>","PeriodicalId":8891,"journal":{"name":"Biomatter","volume":"2 2","pages":"87-93"},"PeriodicalIF":0.0000,"publicationDate":"2012-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4161/biom.20709","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomatter","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4161/biom.20709","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

Abstract

Femoral loosening is one of the most prevalent causes of revision orthopedic surgeries. Cement mantle thickness has been directly correlated with femoral loosening. If the mantle is too thick, there is an increased risk of radiolucent lines and inconsistent densities. Also, the more bone that is reamed out during the procedure can lead to instability, especially if the quality of the bone is compromised due to osteoporosis. Too thin of a mantle can lead to a higher probability for cement fracture, loosening the prosthetic even further. This study has shown that there is an ideal thickness range between 2 to 5 mm that should be kept. From radiographic images one can measure the thickness of the cement mantle showing the loosening characteristics.

水泥填充率对髋关节假体松动的影响。
股骨松动是骨科翻修手术中最常见的原因之一。骨水泥地幔厚度与股骨松动直接相关。如果地幔太厚,辐射线和密度不一致的风险就会增加。此外,在手术过程中,更多的骨头被挖出可能导致不稳定,特别是如果骨头的质量因骨质疏松症而受到损害。太薄的外膜更容易导致骨水泥骨折,使假体进一步松动。这项研究表明,应该保持2到5毫米之间的理想厚度范围。从射线照相图像可以测量出显示松动特征的水泥地幔的厚度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信