{"title":"The 2D Hotelling filter - a quantitative noise-reducing principal-component filter for dynamic PET data, with applications in patient dose reduction.","authors":"Jan Axelsson,&nbsp;Jens Sörensen","doi":"10.1186/1756-6649-13-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>In this paper we apply the principal-component analysis filter (Hotelling filter) to reduce noise from dynamic positron-emission tomography (PET) patient data, for a number of different radio-tracer molecules. We furthermore show how preprocessing images with this filter improves parametric images created from such dynamic sequence.We use zero-mean unit variance normalization, prior to performing a Hotelling filter on the slices of a dynamic time-series. The Scree-plot technique was used to determine which principal components to be rejected in the filter process. This filter was applied to [11C]-acetate on heart and head-neck tumors, [18F]-FDG on liver tumors and brain, and [11C]-Raclopride on brain. Simulations of blood and tissue regions with noise properties matched to real PET data, was used to analyze how quantitation and resolution is affected by the Hotelling filter. Summing varying parts of a 90-frame [18F]-FDG brain scan, we created 9-frame dynamic scans with image statistics comparable to 20 MBq, 60 MBq and 200 MBq injected activity. Hotelling filter performed on slices (2D) and on volumes (3D) were compared.</p><p><strong>Results: </strong>The 2D Hotelling filter reduces noise in the tissue uptake drastically, so that it becomes simple to manually pick out regions-of-interest from noisy data. 2D Hotelling filter introduces less bias than 3D Hotelling filter in focal Raclopride uptake. Simulations show that the Hotelling filter is sensitive to typical blood peak in PET prior to tissue uptake have commenced, introducing a negative bias in early tissue uptake. Quantitation on real dynamic data is reliable. Two examples clearly show that pre-filtering the dynamic sequence with the Hotelling filter prior to Patlak-slope calculations gives clearly improved parametric image quality. We also show that a dramatic dose reduction can be achieved for Patlak slope images without changing image quality or quantitation.</p><p><strong>Conclusions: </strong>The 2D Hotelling-filtering of dynamic PET data is a computer-efficient method that gives visually improved differentiation of different tissues, which we have observed improve manual or automated region-of-interest delineation of dynamic data. Parametric Patlak images on Hotelling-filtered data display improved clarity, compared to non-filtered Patlak slope images without measurable loss of quantitation, and allow a dramatic decrease in patient injected dose.</p>","PeriodicalId":87528,"journal":{"name":"BMC medical physics","volume":"13 ","pages":"1"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1186/1756-6649-13-1","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC medical physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/1756-6649-13-1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

Background: In this paper we apply the principal-component analysis filter (Hotelling filter) to reduce noise from dynamic positron-emission tomography (PET) patient data, for a number of different radio-tracer molecules. We furthermore show how preprocessing images with this filter improves parametric images created from such dynamic sequence.We use zero-mean unit variance normalization, prior to performing a Hotelling filter on the slices of a dynamic time-series. The Scree-plot technique was used to determine which principal components to be rejected in the filter process. This filter was applied to [11C]-acetate on heart and head-neck tumors, [18F]-FDG on liver tumors and brain, and [11C]-Raclopride on brain. Simulations of blood and tissue regions with noise properties matched to real PET data, was used to analyze how quantitation and resolution is affected by the Hotelling filter. Summing varying parts of a 90-frame [18F]-FDG brain scan, we created 9-frame dynamic scans with image statistics comparable to 20 MBq, 60 MBq and 200 MBq injected activity. Hotelling filter performed on slices (2D) and on volumes (3D) were compared.

Results: The 2D Hotelling filter reduces noise in the tissue uptake drastically, so that it becomes simple to manually pick out regions-of-interest from noisy data. 2D Hotelling filter introduces less bias than 3D Hotelling filter in focal Raclopride uptake. Simulations show that the Hotelling filter is sensitive to typical blood peak in PET prior to tissue uptake have commenced, introducing a negative bias in early tissue uptake. Quantitation on real dynamic data is reliable. Two examples clearly show that pre-filtering the dynamic sequence with the Hotelling filter prior to Patlak-slope calculations gives clearly improved parametric image quality. We also show that a dramatic dose reduction can be achieved for Patlak slope images without changing image quality or quantitation.

Conclusions: The 2D Hotelling-filtering of dynamic PET data is a computer-efficient method that gives visually improved differentiation of different tissues, which we have observed improve manual or automated region-of-interest delineation of dynamic data. Parametric Patlak images on Hotelling-filtered data display improved clarity, compared to non-filtered Patlak slope images without measurable loss of quantitation, and allow a dramatic decrease in patient injected dose.

Abstract Image

Abstract Image

Abstract Image

二维霍特林滤波器-用于动态PET数据的定量降噪主成分滤波器,应用于患者剂量降低。
背景:在本文中,我们应用主成分分析滤波器(Hotelling滤波器)来降低动态正电子发射断层扫描(PET)患者数据中的噪声,用于许多不同的放射性示踪剂分子。我们进一步展示了如何用该滤波器预处理图像,以改善从这种动态序列创建的参数图像。在对动态时间序列的切片执行霍特林滤波器之前,我们使用零均值单位方差归一化。采用屏幕图技术确定在滤波过程中应剔除哪些主成分。该过滤器应用于心脏和头颈部肿瘤的[11C]-醋酸酯,肝脏肿瘤和脑的[18F]-FDG,脑的[11C]-Raclopride。模拟的血液和组织区域的噪声特性与真实PET数据相匹配,用于分析霍特林滤波器对定量和分辨率的影响。将90帧[18F]-FDG脑扫描的不同部分相加,我们创建了9帧动态扫描,其图像统计可与20 MBq, 60 MBq和200 MBq注入活动相比较。对切片(2D)和体积(3D)进行Hotelling滤波进行比较。结果:二维Hotelling滤波器大大降低了组织摄取中的噪声,从而使人工从噪声数据中挑选出感兴趣的区域变得简单。2D Hotelling filter引入的偏置比3D Hotelling filter引入的偏置更小。模拟表明,在组织摄取开始之前,Hotelling过滤器对PET的典型血峰敏感,在早期组织摄取中引入负偏置。对真实动态数据的定量分析是可靠的。两个例子清楚地表明,在patak -slope计算之前使用Hotelling滤波器对动态序列进行预滤波可以明显改善参数图像质量。我们还表明,在不改变图像质量或定量的情况下,可以实现帕特拉克斜率图像的显著剂量减少。结论:动态PET数据的二维霍特宁滤波是一种计算机高效的方法,可以从视觉上改善不同组织的分化,我们已经观察到这种方法改善了动态数据的手动或自动兴趣区域描绘。与未过滤的Patlak斜率图像相比,经hotelll滤波数据的参数化Patlak图像显示出更高的清晰度,而没有可测量的定量损失,并允许患者注射剂量显著降低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书