K(3)EDTA Vacuum Tubes Validation for Routine Hematological Testing.

ISRN Hematology Pub Date : 2012-01-01 Epub Date: 2012-07-24 DOI:10.5402/2012/875357
Gabriel Lima-Oliveira, Giuseppe Lippi, Gian Luca Salvagno, Martina Montagnana, Giovanni Poli, Giovanni Pietro Solero, Geraldo Picheth, Gian Cesare Guidi
{"title":"K(3)EDTA Vacuum Tubes Validation for Routine Hematological Testing.","authors":"Gabriel Lima-Oliveira,&nbsp;Giuseppe Lippi,&nbsp;Gian Luca Salvagno,&nbsp;Martina Montagnana,&nbsp;Giovanni Poli,&nbsp;Giovanni Pietro Solero,&nbsp;Geraldo Picheth,&nbsp;Gian Cesare Guidi","doi":"10.5402/2012/875357","DOIUrl":null,"url":null,"abstract":"<p><p>Background and Objective. Some in vitro diagnostic devices (e.g, blood collection vacuum tubes and syringes for blood analyses) are not validated before the quality laboratory managers decide to start using or to change the brand. Frequently, the laboratory or hospital managers select the vacuum tubes for blood collection based on cost considerations or on relevance of a brand. The aim of this study was to validate two dry K(3)EDTA vacuum tubes of different brands for routine hematological testing. Methods. Blood specimens from 100 volunteers in two different K(3)EDTA vacuum tubes were collected by a single, expert phlebotomist. The routine hematological testing was done on Advia 2120i hematology system. The significance of the differences between samples was assessed by paired Student's t-test after checking for normality. The level of statistical significance was set at P < 0.05. Results and Conclusions. Different brand's tubes evaluated can represent a clinically relevant source of variations only on mean platelet volume (MPV) and platelet distribution width (PDW). Basically, our validation will permit the laboratory or hospital managers to select the brand's vacuum tubes validated according to him/her technical or economical reasons for routine hematological tests.</p>","PeriodicalId":14727,"journal":{"name":"ISRN Hematology","volume":"2012 ","pages":"875357"},"PeriodicalIF":0.0000,"publicationDate":"2012-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.5402/2012/875357","citationCount":"21","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ISRN Hematology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5402/2012/875357","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2012/7/24 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 21

Abstract

Background and Objective. Some in vitro diagnostic devices (e.g, blood collection vacuum tubes and syringes for blood analyses) are not validated before the quality laboratory managers decide to start using or to change the brand. Frequently, the laboratory or hospital managers select the vacuum tubes for blood collection based on cost considerations or on relevance of a brand. The aim of this study was to validate two dry K(3)EDTA vacuum tubes of different brands for routine hematological testing. Methods. Blood specimens from 100 volunteers in two different K(3)EDTA vacuum tubes were collected by a single, expert phlebotomist. The routine hematological testing was done on Advia 2120i hematology system. The significance of the differences between samples was assessed by paired Student's t-test after checking for normality. The level of statistical significance was set at P < 0.05. Results and Conclusions. Different brand's tubes evaluated can represent a clinically relevant source of variations only on mean platelet volume (MPV) and platelet distribution width (PDW). Basically, our validation will permit the laboratory or hospital managers to select the brand's vacuum tubes validated according to him/her technical or economical reasons for routine hematological tests.

K(3)EDTA真空管常规血液学检测验证。
背景和目的。一些体外诊断设备(如血液采集真空管和用于血液分析的注射器)在质量实验室管理人员决定开始使用或更换品牌之前没有经过验证。通常,实验室或医院管理人员选择真空管进行采血是基于成本考虑或品牌的相关性。本研究的目的是验证两种不同品牌的干式K(3)EDTA真空管用于常规血液学检测。方法。100名志愿者的血液标本由一位专业的采血师在两个不同的K(3)EDTA真空管中采集。常规血液学检测在Advia 2120i血液学系统上完成。在检验正态性后,采用配对学生t检验来评估样本间差异的显著性。P < 0.05为差异有统计学意义的水平。结果与结论。评估的不同品牌的试管只能代表平均血小板体积(MPV)和血小板分布宽度(PDW)的临床相关变异来源。基本上,我们的验证将允许实验室或医院经理根据他/她的技术或经济原因选择经过验证的品牌真空管进行常规血液学测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信