Toward multiple catheters detection in fluoroscopic image guided interventions.

Liron Yatziv, Mathieu Chartouni, Saurabh Datta, Guillermo Sapiro
{"title":"Toward multiple catheters detection in fluoroscopic image guided interventions.","authors":"Liron Yatziv,&nbsp;Mathieu Chartouni,&nbsp;Saurabh Datta,&nbsp;Guillermo Sapiro","doi":"10.1109/TITB.2012.2189407","DOIUrl":null,"url":null,"abstract":"<p><p>Catheters are routinely inserted via vessels to cavities of the heart during fluoroscopic image guided interventions for electrophysiology (EP) procedures such as ablation. During such interventions, the catheter undergoes nonrigid deformation due to physician interaction, patient's breathing, and cardiac motions. EP clinical applications can benefit from fast and accurate automatic catheter tracking in the fluoroscopic images. The typical low quality in fluoroscopic images and the presence of other medical instruments in the scene make the automatic detection and tracking of catheters in clinical environments very challenging. Toward the development of such an application, a robust and efficient method for detecting and tracking the catheter sheath is developed. The proposed approach exploits the clinical setup knowledge to constrain the search space while boosting both tracking speed and accuracy, and is based on a computationally efficient framework to trace the sheath and simultaneously detect one or multiple catheter tips. The algorithm is based on a modification of the fast marching weighted distance computation that efficiently calculates, on the fly, important geodesic properties in relevant regions of the image. This is followed by a cascade classifier for detecting the catheter tips. The proposed technique is validated on 1107 fluoroscopic images acquired on multiple patients across four different clinics, achieving multiple catheter tracking at a rate of 10 images/s with a very low false positive rate of 1.06.</p>","PeriodicalId":55008,"journal":{"name":"IEEE Transactions on Information Technology in Biomedicine","volume":"16 4","pages":"770-81"},"PeriodicalIF":0.0000,"publicationDate":"2012-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/TITB.2012.2189407","citationCount":"33","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Information Technology in Biomedicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TITB.2012.2189407","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2012/2/28 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 33

Abstract

Catheters are routinely inserted via vessels to cavities of the heart during fluoroscopic image guided interventions for electrophysiology (EP) procedures such as ablation. During such interventions, the catheter undergoes nonrigid deformation due to physician interaction, patient's breathing, and cardiac motions. EP clinical applications can benefit from fast and accurate automatic catheter tracking in the fluoroscopic images. The typical low quality in fluoroscopic images and the presence of other medical instruments in the scene make the automatic detection and tracking of catheters in clinical environments very challenging. Toward the development of such an application, a robust and efficient method for detecting and tracking the catheter sheath is developed. The proposed approach exploits the clinical setup knowledge to constrain the search space while boosting both tracking speed and accuracy, and is based on a computationally efficient framework to trace the sheath and simultaneously detect one or multiple catheter tips. The algorithm is based on a modification of the fast marching weighted distance computation that efficiently calculates, on the fly, important geodesic properties in relevant regions of the image. This is followed by a cascade classifier for detecting the catheter tips. The proposed technique is validated on 1107 fluoroscopic images acquired on multiple patients across four different clinics, achieving multiple catheter tracking at a rate of 10 images/s with a very low false positive rate of 1.06.

透视图像引导介入治疗中多导管检测的探讨。
在电生理(EP)手术(如消融术)的透视图像引导干预过程中,导管通常通过血管插入心脏腔。在这种干预过程中,由于医生的相互作用、患者的呼吸和心脏运动,导管会发生非刚性变形。EP的临床应用可以受益于在透视图像中快速准确的自动导管跟踪。典型的低质量透视图像和现场其他医疗器械的存在使得临床环境中导管的自动检测和跟踪非常具有挑战性。针对这一应用的发展,开发了一种鲁棒且高效的检测和跟踪导管鞘的方法。所提出的方法利用临床设置知识来限制搜索空间,同时提高跟踪速度和准确性,并且基于计算效率的框架来跟踪护套并同时检测一个或多个导管尖端。该算法基于对快速行进加权距离计算的改进,有效地在飞行中计算图像相关区域的重要测地线属性。接下来是用于检测导管尖端的级联分类器。该技术在四个不同诊所的多名患者的1107张透视图像上进行了验证,以10张图像/秒的速度实现了多根导管的跟踪,假阳性率非常低,为1.06。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Transactions on Information Technology in Biomedicine
IEEE Transactions on Information Technology in Biomedicine 工程技术-计算机:跨学科应用
自引率
0.00%
发文量
1
审稿时长
4.8 months
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书