Umut Mengulluoglu, Cagri Altug, H Deniz Ertugrul, Abdulkerim Yildiz, E Melis Ekici, Erhan Dinckaya
{"title":"α-Amylase monitoring by a novel amperometric biosensor based on Au electrode: its optimization, characterization, and application.","authors":"Umut Mengulluoglu, Cagri Altug, H Deniz Ertugrul, Abdulkerim Yildiz, E Melis Ekici, Erhan Dinckaya","doi":"10.3109/10731199.2011.597757","DOIUrl":null,"url":null,"abstract":"<p><p>A low-cost and sensitive amperometric biosensor was developed for the determination of α-amylase activity. The biosensor was constructed by immobilizing glucose oxidase-gelatin via glutaraldehyde on the Au electrode surface. Measurements were carried out chronoamperometrically at -0.7 V. Several parameters such as glucose oxidase activity, gelatin amount, and glutaraldehyde percentage for cross-linking were optimized. Optimum pH, optimum temperature, repeatability, and storage stabilities of the biosensor were identified. Under the optimum experimental conditions, a linear calibration curve was obtained for α-amylase between 0.819 and 13.110 U/ml. Sample analyses were carried out by detecting α-amylase activities in baker's yeast samples.</p>","PeriodicalId":8413,"journal":{"name":"Artificial cells, blood substitutes, and immobilization biotechnology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10731199.2011.597757","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Artificial cells, blood substitutes, and immobilization biotechnology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/10731199.2011.597757","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2011/8/12 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
Abstract
A low-cost and sensitive amperometric biosensor was developed for the determination of α-amylase activity. The biosensor was constructed by immobilizing glucose oxidase-gelatin via glutaraldehyde on the Au electrode surface. Measurements were carried out chronoamperometrically at -0.7 V. Several parameters such as glucose oxidase activity, gelatin amount, and glutaraldehyde percentage for cross-linking were optimized. Optimum pH, optimum temperature, repeatability, and storage stabilities of the biosensor were identified. Under the optimum experimental conditions, a linear calibration curve was obtained for α-amylase between 0.819 and 13.110 U/ml. Sample analyses were carried out by detecting α-amylase activities in baker's yeast samples.