Single-laboratory validation of a GC/MS method for the determination of 27 polycyclic aromatic hydrocarbons (PAHs) in oils and fats.

M Rose, S White, R Macarthur, R G Petch, J Holland, A P Damant
{"title":"Single-laboratory validation of a GC/MS method for the determination of 27 polycyclic aromatic hydrocarbons (PAHs) in oils and fats.","authors":"M Rose,&nbsp;S White,&nbsp;R Macarthur,&nbsp;R G Petch,&nbsp;J Holland,&nbsp;A P Damant","doi":"10.1080/02652030601135936","DOIUrl":null,"url":null,"abstract":"<p><p>A protocol for the measurement of 27 polycyclic aromatic hydrocarbons (PAHs) in vegetable oils by GC/MS has undergone single-laboratory validation. PAHs were measured in three oils (olive pomace, sunflower and coconut oil). Five samples of each oil (one unfortified, and four fortified at concentrations between 2 and 50 microg kg(-1)) were analysed in replicate (four times in separate runs). Two samples (one unfortified and one fortified at 2 microg kg(-1)) of five oils (virgin olive oil, grapeseed oil, toasted sesame oil, olive margarine and palm oil) were also analysed. The validation included an assessment of measurement bias from the results of 120 measurements of a certified reference material (coconut oil BCR CRM458 certified for six PAHs). The method is capable of reliably detecting 26 out of 27 PAHs, at concentration <2 microg kg(-1) which is the European Union maximum limit for benzo[a]pyrene, in vegetable oils, olive pomace oil, sunflower oil and coconut oil. Quantitative results were obtained that are fit for purpose for concentrations from <2 to 50 microg kg(-1) for 24 out of 27 PAHs in olive pomace oil, sunflower oil and coconut oil. The reliable detection of 2 microg kg(-1) of PAHs in five additional oils (virgin olive oil, grapeseed oil, toasted sesame oil, olive margarine and palm oil) has been demonstrated. The method failed to produce fit-for-purpose results for the measurement of dibenzo[a,h]pyrene, anthanthrene and cyclopenta[c,d]pyrene. The reason for the failure was the large variation in results. The likely cause was the lack of availability of (13)C isotope internal standards for these PAHs at the time of the study. The protocol has been shown to be fit-for-purpose and is suitable for formal validation by inter-laboratory collaborative study.</p>","PeriodicalId":12138,"journal":{"name":"Food additives and contaminants","volume":"24 6","pages":"635-51"},"PeriodicalIF":0.0000,"publicationDate":"2007-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/02652030601135936","citationCount":"32","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Food additives and contaminants","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/02652030601135936","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 32

Abstract

A protocol for the measurement of 27 polycyclic aromatic hydrocarbons (PAHs) in vegetable oils by GC/MS has undergone single-laboratory validation. PAHs were measured in three oils (olive pomace, sunflower and coconut oil). Five samples of each oil (one unfortified, and four fortified at concentrations between 2 and 50 microg kg(-1)) were analysed in replicate (four times in separate runs). Two samples (one unfortified and one fortified at 2 microg kg(-1)) of five oils (virgin olive oil, grapeseed oil, toasted sesame oil, olive margarine and palm oil) were also analysed. The validation included an assessment of measurement bias from the results of 120 measurements of a certified reference material (coconut oil BCR CRM458 certified for six PAHs). The method is capable of reliably detecting 26 out of 27 PAHs, at concentration <2 microg kg(-1) which is the European Union maximum limit for benzo[a]pyrene, in vegetable oils, olive pomace oil, sunflower oil and coconut oil. Quantitative results were obtained that are fit for purpose for concentrations from <2 to 50 microg kg(-1) for 24 out of 27 PAHs in olive pomace oil, sunflower oil and coconut oil. The reliable detection of 2 microg kg(-1) of PAHs in five additional oils (virgin olive oil, grapeseed oil, toasted sesame oil, olive margarine and palm oil) has been demonstrated. The method failed to produce fit-for-purpose results for the measurement of dibenzo[a,h]pyrene, anthanthrene and cyclopenta[c,d]pyrene. The reason for the failure was the large variation in results. The likely cause was the lack of availability of (13)C isotope internal standards for these PAHs at the time of the study. The protocol has been shown to be fit-for-purpose and is suitable for formal validation by inter-laboratory collaborative study.

GC/MS法测定油脂中27种多环芳烃(PAHs)的单实验室验证
建立了植物油中27种多环芳烃(PAHs)的GC/MS测定方法。在三种油(橄榄渣、葵花籽油和椰子油)中测量了多环芳烃。每种油的5个样品(1个未强化,4个强化浓度在2到50微克公斤(-1)之间)被重复分析(在不同的运行中进行4次)。还分析了五种油(初榨橄榄油、葡萄籽油、烤芝麻油、橄榄人造黄油和棕榈油)的两种样品(一种未经强化,另一种强化至2微克公斤(-1))。验证包括对认证标准物质(椰子油BCR CRM458认证六种多环芳烃)的120次测量结果的测量偏差评估。该方法能够可靠地检测27种多环芳烃中的26种
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信