Frequency rhythmic electrical modulation system (FREMS) on H-reflex amplitudes in healthy subjects.

Europa medicophysica Pub Date : 2007-03-01 Epub Date: 2006-12-12
M Barrella, R Toscano, M Goldoni, M Bevilacqua
{"title":"Frequency rhythmic electrical modulation system (FREMS) on H-reflex amplitudes in healthy subjects.","authors":"M Barrella,&nbsp;R Toscano,&nbsp;M Goldoni,&nbsp;M Bevilacqua","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>Changes in the amplitude of Hoffmann reflex (H-reflex) may reflect variations in the characteristics of the largely monosynaptic circuitry that is explored and are a possible target for diagnostic and physical therapeutic intervention. However, previous attempts to induce predictable changes in the H-reflex amplitude by transcutaneous electrical nervous stimulation (TENS) have generally failed. Previous workers applied fixed frequency in the low- (2-5 Hz) or in the high- (100 Hz) field, but they did not attempt to vary frequency and/or impulse duration in time.</p><p><strong>Methods: </strong>We evaluated the effect of a new type of painless electric stimulation, i.e. frequency rhythmic electrical modulation system (FREMS). FREMS is characterized by the use of transcutaneous electric pulses with sequentially modulated frequency (f: 1-39 Hz) and width (w: 10-40 micro s) at constant, perceptive threshold voltage (approximately 150 V). FREMS was applied at the abductor hallucis muscle (AHM), as conditioning stimulus of the H-reflex which was recorded ipsilaterally at the soleus muscle, according to the classic method, in 10 normal volunteers (age range 21-40 years).</p><p><strong>Results: </strong>H-reflex amplitude was substantially decreased (-50%) during FREMS and H-reflex amplitude variations were influenced by w/f variation in time during FREMS subphase C in a predictable way (r(2)=0.43; P<0.001). Our results suggest an effective ability of FREMS to modulate H reflex amplitude.</p><p><strong>Conclusions: </strong>The ability to achieve large and predictable changes of the H-reflex amplitude simply by modulating both frequency and duration of a conditioning painless electrical stimulation offers new possibilities for the treatment of diseases characterized by motoneuron excitability abnormalities.</p>","PeriodicalId":87180,"journal":{"name":"Europa medicophysica","volume":"43 1","pages":"37-47"},"PeriodicalIF":0.0000,"publicationDate":"2007-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Europa medicophysica","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2006/12/12 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: Changes in the amplitude of Hoffmann reflex (H-reflex) may reflect variations in the characteristics of the largely monosynaptic circuitry that is explored and are a possible target for diagnostic and physical therapeutic intervention. However, previous attempts to induce predictable changes in the H-reflex amplitude by transcutaneous electrical nervous stimulation (TENS) have generally failed. Previous workers applied fixed frequency in the low- (2-5 Hz) or in the high- (100 Hz) field, but they did not attempt to vary frequency and/or impulse duration in time.

Methods: We evaluated the effect of a new type of painless electric stimulation, i.e. frequency rhythmic electrical modulation system (FREMS). FREMS is characterized by the use of transcutaneous electric pulses with sequentially modulated frequency (f: 1-39 Hz) and width (w: 10-40 micro s) at constant, perceptive threshold voltage (approximately 150 V). FREMS was applied at the abductor hallucis muscle (AHM), as conditioning stimulus of the H-reflex which was recorded ipsilaterally at the soleus muscle, according to the classic method, in 10 normal volunteers (age range 21-40 years).

Results: H-reflex amplitude was substantially decreased (-50%) during FREMS and H-reflex amplitude variations were influenced by w/f variation in time during FREMS subphase C in a predictable way (r(2)=0.43; P<0.001). Our results suggest an effective ability of FREMS to modulate H reflex amplitude.

Conclusions: The ability to achieve large and predictable changes of the H-reflex amplitude simply by modulating both frequency and duration of a conditioning painless electrical stimulation offers new possibilities for the treatment of diseases characterized by motoneuron excitability abnormalities.

频率节律性电调制系统(FREMS)对健康人h反射振幅的影响。
目的:霍夫曼反射(h反射)振幅的变化可能反映了所探索的大部分单突触电路特征的变化,并且可能是诊断和物理治疗干预的目标。然而,以前尝试通过经皮神经电刺激(TENS)诱导可预测的h反射振幅变化通常失败。以前的工作人员在低(2-5 Hz)或高(100 Hz)领域应用固定频率,但他们没有尝试及时改变频率和/或脉冲持续时间。方法:评价一种新型无痛电刺激的效果,即频率节律性电调制系统(FREMS)。FREMS的特点是在恒定的感知阈值电压(约150 V)下,使用频率(f: 1-39 Hz)和宽度(w: 10-40微秒)顺序调制的经皮电脉冲。FREMS应用于幻觉外展肌(AHM),作为h反射的条件刺激,根据经典方法,在10名正常志愿者(年龄范围21-40岁)的同侧比目鱼肌上记录h反射。结果:在FREMS期间h反射振幅显著降低(-50%),并且h反射振幅的变化受FREMS亚阶段C的w/f时间变化的影响,且可预测(r(2)=0.43;结论:仅仅通过调节调节性无痛电刺激的频率和持续时间就能实现h反射幅度的大而可预测的变化,这为治疗以运动神经元兴奋性异常为特征的疾病提供了新的可能性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书