The compangle: a new goniometer for joint angle measurements of the hand. A technical note.

Europa medicophysica Pub Date : 2006-03-01
H J Stam, M S Ardon, A C den Ouden, T A R Schreuders, M E Roebroeck
{"title":"The compangle: a new goniometer for joint angle measurements of the hand. A technical note.","authors":"H J Stam,&nbsp;M S Ardon,&nbsp;A C den Ouden,&nbsp;T A R Schreuders,&nbsp;M E Roebroeck","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The accuracy of joint angle measurement of the hand may be negatively influenced by joint swelling, deformation and other obstacles. We developed an alternative goniometer with clear ergonomic advantages, especially for the measurement of small joints. This new concept of goniometry is described and preliminary results on the reliability of the measurements are presented. The intraclass correlation coefficients (ICCs) and the standard error of measurements (SEMs) of the alternative goniometer are greater respectively smaller than a conventional goniometer, indicating a better intratester reliability.</p>","PeriodicalId":87180,"journal":{"name":"Europa medicophysica","volume":"42 1","pages":"37-40"},"PeriodicalIF":0.0000,"publicationDate":"2006-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Europa medicophysica","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The accuracy of joint angle measurement of the hand may be negatively influenced by joint swelling, deformation and other obstacles. We developed an alternative goniometer with clear ergonomic advantages, especially for the measurement of small joints. This new concept of goniometry is described and preliminary results on the reliability of the measurements are presented. The intraclass correlation coefficients (ICCs) and the standard error of measurements (SEMs) of the alternative goniometer are greater respectively smaller than a conventional goniometer, indicating a better intratester reliability.

compangle:一种用于测量手关节角度的新测角仪。一个技术说明。
关节肿胀、变形等障碍会影响手部关节角度测量的准确性。我们开发了一种具有明显人体工程学优势的替代测角仪,特别是用于测量小关节。描述了这一新的几何概念,并给出了测量结果的初步可靠性。替代测角仪的类内相关系数(ICCs)和测量标准误差(SEMs)分别大于小于常规测角仪,表明其具有更好的类内可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书