Adhesion of Pollen Particles to Daily Disposable Soft Contact Lenses.

IF 1.4 Q3 OPHTHALMOLOGY
Clinical Optometry Pub Date : 2021-03-25 eCollection Date: 2021-01-01 DOI:10.2147/OPTO.S297531
Tatsuya Mimura, Hiroshi Fujishima, Eiichi Uchio, Kazumi Fukagawa, Makoto Kawashima, Kazuma Kitsu, Hiroaki Horikawa, Atsushi Mizota
{"title":"Adhesion of Pollen Particles to Daily Disposable Soft Contact Lenses.","authors":"Tatsuya Mimura,&nbsp;Hiroshi Fujishima,&nbsp;Eiichi Uchio,&nbsp;Kazumi Fukagawa,&nbsp;Makoto Kawashima,&nbsp;Kazuma Kitsu,&nbsp;Hiroaki Horikawa,&nbsp;Atsushi Mizota","doi":"10.2147/OPTO.S297531","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Pollen and proteins attached to soft contact lenses (SCLs) exacerbate allergic conjunctivitis. The material of SCLs may affect the pollen adhesion to the SCLs. The factors associated with the number of pollen particles that are adherent to daily disposable SCL were investigated.</p><p><strong>Methods: </strong>Pollen particles were experimentally exposed to the contact lens surface of 12 types of SCLs for 1 hour, and the SCLs were washed and rinsed with a physiological saline (n=10 for each SCL type). A total of 120 contact lenses were used in this study. The pollen particles attached to the SCL were observed and photographed under a microscope. The influence of the materials of the SCLs on the degree of pollen adhesion were investigated.</p><p><strong>Results: </strong>The number of residual pollen particles attached to SCLs was in the range from 0-293/area of 200×200 µm. Percentage of pollen adhesion area of the surface of the SCL was in the range from 0.01% to 3.25%. There were significant differences in both the number and adhesion area of pollen particles among the 12 types of SCLs tested (<i>P</i><0.0001 and <i>P</i><0.0001, respectively). The number of pollen particles adhered to SCLs was significantly higher in colored SCLs than clear SCLs (unpaired <i>t</i>-test, p<0.001). The portion of pollen adhesion area was the lowest in the silicone hydrogel SCLs made with delefilcon-A (0.01 ± 0.02%).</p><p><strong>Conclusion: </strong>Pollen adhesion in daily disposable SCLs depends on the characteristics and materials of the SCLs and was high in colored SCLs and lowest in delefilcon-A silicone hydrogel SCL. These results suggest that colored SCLs are not preferred during pollen season.</p>","PeriodicalId":43701,"journal":{"name":"Clinical Optometry","volume":"13 ","pages":"93-101"},"PeriodicalIF":1.4000,"publicationDate":"2021-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/ed/8b/opto-13-93.PMC8007601.pdf","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Optometry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/OPTO.S297531","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 6

Abstract

Purpose: Pollen and proteins attached to soft contact lenses (SCLs) exacerbate allergic conjunctivitis. The material of SCLs may affect the pollen adhesion to the SCLs. The factors associated with the number of pollen particles that are adherent to daily disposable SCL were investigated.

Methods: Pollen particles were experimentally exposed to the contact lens surface of 12 types of SCLs for 1 hour, and the SCLs were washed and rinsed with a physiological saline (n=10 for each SCL type). A total of 120 contact lenses were used in this study. The pollen particles attached to the SCL were observed and photographed under a microscope. The influence of the materials of the SCLs on the degree of pollen adhesion were investigated.

Results: The number of residual pollen particles attached to SCLs was in the range from 0-293/area of 200×200 µm. Percentage of pollen adhesion area of the surface of the SCL was in the range from 0.01% to 3.25%. There were significant differences in both the number and adhesion area of pollen particles among the 12 types of SCLs tested (P<0.0001 and P<0.0001, respectively). The number of pollen particles adhered to SCLs was significantly higher in colored SCLs than clear SCLs (unpaired t-test, p<0.001). The portion of pollen adhesion area was the lowest in the silicone hydrogel SCLs made with delefilcon-A (0.01 ± 0.02%).

Conclusion: Pollen adhesion in daily disposable SCLs depends on the characteristics and materials of the SCLs and was high in colored SCLs and lowest in delefilcon-A silicone hydrogel SCL. These results suggest that colored SCLs are not preferred during pollen season.

Abstract Image

Abstract Image

Abstract Image

花粉颗粒对日用一次性软性隐形眼镜的粘附作用。
目的:附着在软性隐形眼镜(SCLs)上的花粉和蛋白质会加重过敏性结膜炎。花柱的材料可能影响花粉对花柱的粘附。研究了影响每日一次性SCL上附着花粉粒数的因素。方法:实验将花粉颗粒暴露于12种SCL的接触镜表面1小时,然后用生理盐水冲洗SCL(每种SCL 10例)。本研究共使用了120副隐形眼镜。在显微镜下观察和拍摄附着在SCL上的花粉颗粒。研究了稻壳材料对花粉粘附程度的影响。结果:scl上残留花粉粒数在0 ~ 293个/ 200×200µm范围内。SCL表面花粉粘附面积百分比在0.01% ~ 3.25%之间。结论:日常一次性SCL的花粉粘附性与SCL的特性和材料有关,有色SCL的花粉粘附性较高,delefilcon-A硅酮水凝胶SCL的花粉粘附性最低。这些结果表明,在花粉季节,有色的scl不受欢迎。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Clinical Optometry
Clinical Optometry OPHTHALMOLOGY-
CiteScore
3.00
自引率
5.90%
发文量
29
审稿时长
16 weeks
期刊介绍: Clinical Optometry is an international, peer-reviewed, open access journal focusing on clinical optometry. All aspects of patient care are addressed within the journal as well as the practice of optometry including economic and business analyses. Basic and clinical research papers are published that cover all aspects of optics, refraction and its application to the theory and practice of optometry. Specific topics covered in the journal include: Theoretical and applied optics, Delivery of patient care in optometry practice, Refraction and correction of errors, Screening and preventative aspects of eye disease, Extended clinical roles for optometrists including shared care and provision of medications, Teaching and training optometrists, International aspects of optometry, Business practice, Patient adherence, quality of life, satisfaction, Health economic evaluations.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信