The strain and strain rate imaging paradox in echocardiography: overabundant literature in the last two decades but still uncertain clinical utility in an individual case.

Gian Luigi Nicolosi
{"title":"The strain and strain rate imaging paradox in echocardiography: overabundant literature in the last two decades but still uncertain clinical utility in an individual case.","authors":"Gian Luigi Nicolosi","doi":"10.5114/amsad.2020.103032","DOIUrl":null,"url":null,"abstract":"<p><p>Almost two decades ago strain and strain rate imaging were proposed as a new, potentially more sensitive modality for quantifying both regional and global myocardial function. Until now, however, strain and strain rate imaging have been slow to be incorporated into everyday clinical practice. More recently, two dimensional strain has been claimed as of greater clinical utility, given that it is angle independent, with improved feasibility and reproducibility as compared to tissue Doppler strain. Nevertheless, speckle tracking strain is reliant on 2D image quality and frame rates. Three dimensional speckle tracking could eliminate the problem of through-plane motion inherent in 2D imaging, but 3D strain is currently limited by low frame rates. Another limitation of strain imaging is that the results are dependent on the ultrasound machine on which analyses are performed, with variability in measurements between different vendors. Despite the diagnostic and prognostic advantages of 2D strain, there is a lack of specific therapeutic interventions based on strain and a paucity of long-term large-scale randomized trial evidence on cardiovascular outcomes. After overabundant literature the same definition of normal cut-off values is controversial and not univocal. Further studies are needed, involving both manufacturers and medical professionals, on the additive contribution, possibly different case by case, of interfering and artifactual factors, aside from myocardial function per se. These artifactual determinants and motion artifacts components could be dominant in individual cases and should always be taken into account in the clinical decision making process in a single case.</p>","PeriodicalId":8317,"journal":{"name":"Archives of Medical Sciences. Atherosclerotic Diseases","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/77/b9/AMS-AD-5-43128.PMC7885811.pdf","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Medical Sciences. Atherosclerotic Diseases","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5114/amsad.2020.103032","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2020/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

Abstract

Almost two decades ago strain and strain rate imaging were proposed as a new, potentially more sensitive modality for quantifying both regional and global myocardial function. Until now, however, strain and strain rate imaging have been slow to be incorporated into everyday clinical practice. More recently, two dimensional strain has been claimed as of greater clinical utility, given that it is angle independent, with improved feasibility and reproducibility as compared to tissue Doppler strain. Nevertheless, speckle tracking strain is reliant on 2D image quality and frame rates. Three dimensional speckle tracking could eliminate the problem of through-plane motion inherent in 2D imaging, but 3D strain is currently limited by low frame rates. Another limitation of strain imaging is that the results are dependent on the ultrasound machine on which analyses are performed, with variability in measurements between different vendors. Despite the diagnostic and prognostic advantages of 2D strain, there is a lack of specific therapeutic interventions based on strain and a paucity of long-term large-scale randomized trial evidence on cardiovascular outcomes. After overabundant literature the same definition of normal cut-off values is controversial and not univocal. Further studies are needed, involving both manufacturers and medical professionals, on the additive contribution, possibly different case by case, of interfering and artifactual factors, aside from myocardial function per se. These artifactual determinants and motion artifacts components could be dominant in individual cases and should always be taken into account in the clinical decision making process in a single case.

Abstract Image

超声心动图的应变和应变率成像悖论:近二十年来文献过多,但在个别病例中的临床应用仍不确定。
大约20年前,应变和应变率成像作为一种新的、可能更敏感的方式被提出,用于量化区域和全局心肌功能。然而,到目前为止,应变和应变率成像已缓慢纳入日常临床实践。最近,二维应变被认为具有更大的临床用途,因为它与角度无关,与组织多普勒应变相比,具有更高的可行性和可重复性。然而,斑点跟踪应变依赖于二维图像质量和帧速率。三维散斑跟踪可以消除二维成像固有的平面运动问题,但3D应变目前受到低帧率的限制。应变成像的另一个限制是结果依赖于进行分析的超声机器,不同供应商之间的测量结果存在差异。尽管2D菌株在诊断和预后方面具有优势,但缺乏基于菌株的特异性治疗干预措施,并且缺乏关于心血管结局的长期大规模随机试验证据。在大量的文献之后,正常截止值的相同定义是有争议的,并不是明确的。除了心肌功能本身外,还需要制造商和医疗专业人员进一步研究干扰因素和人为因素的累加作用(可能因情况不同而不同)。这些人为决定因素和运动人为成分可能在个别病例中占主导地位,在单个病例的临床决策过程中应始终考虑到这些因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信