{"title":"[Quality control of radioligand assay for glutamic acid decarboxylase antibody].","authors":"Gan Huang, Zhi-guang Zhou, Jian Peng","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To supply the quality control for glutamic acid decarboxylase antibody (GAD-Ab) measurement using radioligand assay.</p><p><strong>Methods: </strong>The quality control of GAD-Ab determined with radioligand assay in 83 batches was analyzed.</p><p><strong>Results: </strong>The intra-assay coefficient of variation (CV) was 4.3% to approximately 8.3% and the inter-assay CV was 7.1% to approximately 10.8%. A ratio of signal to noise (S/N) with 15 or more was defined as a valid measurement. Of the 83 batches, 67 batches (80.7%) met with the standard and the other 16 (19.3%) were not qualified. When the results were analyzed according to the season, the failure rate in summer was significantly higher than that in winter (38.5% vs 4.8%, P < 0.05). In addition, the mean value of S/N in summer was significantly lower than that in winter ( 14.1 +/- 7. 3 vs. 21.5 +/- 5.2, P < 0.01). Among the failed batches, 68.8% (11/16) was caused by TBST buffer and 50% (8/16) due to the increased temperature of TBST buffer. Other causes for the failure included the invalidation of reagents for in vitro transcription and translation.</p><p><strong>Conclusion: </strong>TBST buffer and other influential factors of radioligand assay in determining GAD-Ab, should be controlled strictly to ensure a reliable and repeatable result.</p>","PeriodicalId":13115,"journal":{"name":"Hunan yi ke da xue xue bao = Hunan yike daxue xuebao = Bulletin of Hunan Medical University","volume":"28 6","pages":"597-600"},"PeriodicalIF":0.0000,"publicationDate":"2003-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hunan yi ke da xue xue bao = Hunan yike daxue xuebao = Bulletin of Hunan Medical University","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: To supply the quality control for glutamic acid decarboxylase antibody (GAD-Ab) measurement using radioligand assay.
Methods: The quality control of GAD-Ab determined with radioligand assay in 83 batches was analyzed.
Results: The intra-assay coefficient of variation (CV) was 4.3% to approximately 8.3% and the inter-assay CV was 7.1% to approximately 10.8%. A ratio of signal to noise (S/N) with 15 or more was defined as a valid measurement. Of the 83 batches, 67 batches (80.7%) met with the standard and the other 16 (19.3%) were not qualified. When the results were analyzed according to the season, the failure rate in summer was significantly higher than that in winter (38.5% vs 4.8%, P < 0.05). In addition, the mean value of S/N in summer was significantly lower than that in winter ( 14.1 +/- 7. 3 vs. 21.5 +/- 5.2, P < 0.01). Among the failed batches, 68.8% (11/16) was caused by TBST buffer and 50% (8/16) due to the increased temperature of TBST buffer. Other causes for the failure included the invalidation of reagents for in vitro transcription and translation.
Conclusion: TBST buffer and other influential factors of radioligand assay in determining GAD-Ab, should be controlled strictly to ensure a reliable and repeatable result.
目的:为谷氨酸脱羧酶抗体(GAD-Ab)放射配体测定提供质量控制。方法:对83批放射性配体法测定GAD-Ab的质量控制进行分析。结果:测定内变异系数(CV)为4.3% ~约8.3%,测定间变异系数为7.1% ~约10.8%。信噪比(S/N)大于等于15被定义为有效测量。83个批次中,合格67个批次(80.7%),不合格16个批次(19.3%)。按季节分析结果,夏季的不合格率显著高于冬季(38.5% vs 4.8%, P < 0.05)。夏季S/N均值显著低于冬季(14.1 +/- 7)。3 vs. 21.5 +/- 5.2, P < 0.01)。在不合格批次中,68.8%(11/16)是由TBST缓冲液引起的,50%(8/16)是由于TBST缓冲液温度升高引起的。失败的其他原因包括体外转录和翻译试剂的失效。结论:严格控制TBST缓冲液等影响放射性配体法测定GAD-Ab的因素,确保结果可靠、重复性好。