Intracellular Ca2+ measurements in live cells by rapid line scan confocal microscopy: simplified calibration methodology.

David M Plank, Mark A Sussman
{"title":"Intracellular Ca2+ measurements in live cells by rapid line scan confocal microscopy: simplified calibration methodology.","authors":"David M Plank,&nbsp;Mark A Sussman","doi":"10.1007/s11022-004-2043-8","DOIUrl":null,"url":null,"abstract":"<p><p>Altered intracellular Ca2+ dynamics are characteristically observed in cardiomyocytes from failing hearts. Studies of Ca2+ handling in myocytes predominantly use Fluo-3 AM, a visible light excitable Ca2+ chelating fluorescent dye in conjunction with rapid line-scanning confocal microscopy. However, Fluo-3 AM does not allow for traditional ratiometric determination of intracellular Ca2+ concentration and has required use of mathematic correction factors with values obtained from separate procedures to convert Fluo-3 AM fluorescence to appropriate CA2+ concentrations. This study describes methodology to directly measure intracellular Ca2+ levels using inactivated, Fluo-3 AM loaded cardiomyocytes equilibrated with Ca2+ concentration standards. Titration of Ca2+ concentration exhibits a linear relationship to increasing Fluo-3 AM fluorescence intensity. Images obtained from individual myocyte confocal scans were recorded, average pixel intensity values were calculated, and a plot is generated relating the average pixel intensity to known Ca2+ concentrations. These standard plots can be used to convert transient Ca2+ fluorescence obtained with experimental cells to Ca2+ concentrations by linear regression analysis. Standards are determined on the same microscope used for acquisition of unknown Ca2+ concentrations, simplifying data interpretaton and assuring accuracy of conversion values. This procedure eliminates additional equipment, ratiometric imaging, and mathematic correction factors and should be used to investigators requiring a straightforward method for measuring Ca2+ concentrations in live cells using Ca2+-chelating dyes exhibiting variable fluorescence intensity.</p>","PeriodicalId":80082,"journal":{"name":"Methods in cell science : an official journal of the Society for In Vitro Biology","volume":"25 3-4","pages":"123-33"},"PeriodicalIF":0.0000,"publicationDate":"2003-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/s11022-004-2043-8","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Methods in cell science : an official journal of the Society for In Vitro Biology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s11022-004-2043-8","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

Altered intracellular Ca2+ dynamics are characteristically observed in cardiomyocytes from failing hearts. Studies of Ca2+ handling in myocytes predominantly use Fluo-3 AM, a visible light excitable Ca2+ chelating fluorescent dye in conjunction with rapid line-scanning confocal microscopy. However, Fluo-3 AM does not allow for traditional ratiometric determination of intracellular Ca2+ concentration and has required use of mathematic correction factors with values obtained from separate procedures to convert Fluo-3 AM fluorescence to appropriate CA2+ concentrations. This study describes methodology to directly measure intracellular Ca2+ levels using inactivated, Fluo-3 AM loaded cardiomyocytes equilibrated with Ca2+ concentration standards. Titration of Ca2+ concentration exhibits a linear relationship to increasing Fluo-3 AM fluorescence intensity. Images obtained from individual myocyte confocal scans were recorded, average pixel intensity values were calculated, and a plot is generated relating the average pixel intensity to known Ca2+ concentrations. These standard plots can be used to convert transient Ca2+ fluorescence obtained with experimental cells to Ca2+ concentrations by linear regression analysis. Standards are determined on the same microscope used for acquisition of unknown Ca2+ concentrations, simplifying data interpretaton and assuring accuracy of conversion values. This procedure eliminates additional equipment, ratiometric imaging, and mathematic correction factors and should be used to investigators requiring a straightforward method for measuring Ca2+ concentrations in live cells using Ca2+-chelating dyes exhibiting variable fluorescence intensity.

细胞内Ca2+测量活细胞通过快速线扫描共聚焦显微镜:简化的校准方法。
细胞内Ca2+动力学的改变是心脏衰竭心肌细胞的特征性观察。心肌细胞中Ca2+处理的研究主要使用Fluo-3 AM,这是一种可见光可激发的Ca2+螯合荧光染料,与快速线扫描共聚焦显微镜结合使用。然而,Fluo-3 AM不允许传统的比例测定细胞内Ca2+浓度,并且需要使用从单独程序获得的数值的数学校正因子将Fluo-3 AM荧光转换为适当的Ca2+浓度。本研究描述了使用与Ca2+浓度标准平衡的失活的Fluo-3 AM负载心肌细胞直接测量细胞内Ca2+水平的方法。钙离子浓度的滴定与Fluo-3 AM荧光强度的增加呈线性关系。记录从单个肌细胞共聚焦扫描获得的图像,计算平均像素强度值,并生成与已知Ca2+浓度相关的平均像素强度图。通过线性回归分析,这些标准图可用于将实验细胞获得的瞬态Ca2+荧光转换为Ca2+浓度。在用于获取未知Ca2+浓度的同一显微镜上确定标准,简化数据解释并确保转换值的准确性。该程序消除了额外的设备,比例成像,和数学校正因素,并应用于研究者需要一个直接的方法来测量Ca2+浓度在活细胞使用Ca2+螯合染料显示可变荧光强度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信