Control methods for mineral oil mists.

David Leith, John Volckens, Maryanne G Boundy, David Hands
{"title":"Control methods for mineral oil mists.","authors":"David Leith,&nbsp;John Volckens,&nbsp;Maryanne G Boundy,&nbsp;David Hands","doi":"10.1080/10473220390237412","DOIUrl":null,"url":null,"abstract":"<p><p>Effective mist collection is important, but it is not the only determinant of mist concentration in plant air. Oil-based metalworking fluids such as straight and soluble oils contain semivolatile hydrocarbons. When these fluids form a mist, their semivolatile components partition between the vapor and mist phases depending on the makeup of the mist and on local conditions. This article addresses the relationship between the concentrations of semivolatile hydrocarbons in the vapor and mist phases using theory for partitioning developed in the field of atmospheric chemistry. Mist can be removed effectively in a collector that uses a HEPA filter as its final collection stage. Acceptable HEPA lifetime requires effective upstream stages that reduce mist loading to the HEPA; furthermore, acceptable HEPA performance requires that it be installed and maintained properly. Collectors designed to remove mist do not remove vapor, and as collector exhaust mixes into cooler plant air that already contains some mist, vapor from the collector can repartition to increase the mist concentration in the plant. Assessing the effect of vapor-to-mist repartitioning is complicated; however, repartitioning may be important for many of the compounds contained in oil-based metalworking fluids. Conditions that minimize vapor-to-mist repartitioning, such as ventilating the plant with clean outdoor air, increasing plant temperature, or controlling the release of vapor, may also be expensive, uncomfortable to plant occupants, or impractical from an engineering standpoint. As a result, very low mist concentrations in plant air may be difficult to attain.</p>","PeriodicalId":8182,"journal":{"name":"Applied occupational and environmental hygiene","volume":"18 11","pages":"883-9"},"PeriodicalIF":0.0000,"publicationDate":"2003-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/10473220390237412","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied occupational and environmental hygiene","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/10473220390237412","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Effective mist collection is important, but it is not the only determinant of mist concentration in plant air. Oil-based metalworking fluids such as straight and soluble oils contain semivolatile hydrocarbons. When these fluids form a mist, their semivolatile components partition between the vapor and mist phases depending on the makeup of the mist and on local conditions. This article addresses the relationship between the concentrations of semivolatile hydrocarbons in the vapor and mist phases using theory for partitioning developed in the field of atmospheric chemistry. Mist can be removed effectively in a collector that uses a HEPA filter as its final collection stage. Acceptable HEPA lifetime requires effective upstream stages that reduce mist loading to the HEPA; furthermore, acceptable HEPA performance requires that it be installed and maintained properly. Collectors designed to remove mist do not remove vapor, and as collector exhaust mixes into cooler plant air that already contains some mist, vapor from the collector can repartition to increase the mist concentration in the plant. Assessing the effect of vapor-to-mist repartitioning is complicated; however, repartitioning may be important for many of the compounds contained in oil-based metalworking fluids. Conditions that minimize vapor-to-mist repartitioning, such as ventilating the plant with clean outdoor air, increasing plant temperature, or controlling the release of vapor, may also be expensive, uncomfortable to plant occupants, or impractical from an engineering standpoint. As a result, very low mist concentrations in plant air may be difficult to attain.

矿物油雾的控制方法。
有效的雾收集很重要,但它不是植物空气中雾浓度的唯一决定因素。油基金属加工液,如直油和可溶性油,含有半挥发性碳氢化合物。当这些流体形成薄雾时,根据薄雾的组成和当地条件,它们的半挥发性成分在蒸汽和雾相之间分裂。本文利用大气化学领域发展起来的分划理论,讨论了蒸汽和雾相中半挥发性碳氢化合物浓度之间的关系。雾可以在使用HEPA过滤器作为最后收集阶段的收集器中有效地去除。可接受的HEPA寿命要求有效的上游阶段,以减少HEPA的雾负荷;此外,可接受的HEPA性能要求其安装和维护得当。设计用于去除雾的收集器不能去除蒸汽,并且当收集器排出的气体混合到已经含有一些雾的较冷的工厂空气中时,收集器中的蒸汽可以重新分配以增加工厂中的雾浓度。评估蒸汽到雾再分配的效果是复杂的;然而,对于油基金属加工液中含有的许多化合物来说,重新分配可能是重要的。尽量减少蒸汽到雾再分配的条件,例如用清洁的室外空气给植物通风,提高植物温度或控制蒸汽的释放,也可能是昂贵的,对植物居住者来说不舒服,或者从工程的角度来看不切实际。因此,很低的雾浓度在工厂空气可能很难达到。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信