{"title":"Integrated hand-held electrochemical sensor for multicomponent detection in urine","authors":"Jiang Liu ,&nbsp;Wei Lu ,&nbsp;Lu Zhang ,&nbsp;Jiao Yang ,&nbsp;Zhong-Ping Yao ,&nbsp;Yongcheng He ,&nbsp;Yingchun Li","doi":"10.1016/j.bios.2021.113534","DOIUrl":null,"url":null,"abstract":"<div><p><span>Electrochemical sensors<span><span><span> have shown great advantage and application potential in point-of-care testing (POCT) related scenarios. However, some fatal problems plague its widespread utilization, which include the susceptibility of sensors to interference in real samples (e.g. pH), the contradiction between the limited objects detectable for most sensors and the requirement of multi-target analysis in most cases, and the complicated procedures in sensor preparation as well as in routine use. This paper contributed a tip-like electrochemical sensor prototype. By integrated with a commercial pipettor, it fulfilled semi-automatic assay procedure of sampling, detection and rinsing, thus saving operational time and manual work. The tip sensor owns the property of simple fabrication and is free from any modification of extra bio/chem materials. Moreover, built on multiple electrochemical signal outputs including open circuit potential, peak current and potential of specific </span>electrochemical reaction, this work established a novel multi-component sensing strategy, wherein detection of </span>uric acid<span> (UA), urea and pH in urine samples was realized by using one single working electrode. The detection range for the above targets is 5.0~600 μM for UA, 4.0~8.0 for pH and 0.5~7.0 mM for urea with the detection limits (</span></span></span><em>S</em>/<em>N</em><span> = 3) of 0.05 μM for UA and 5.4 μM for urea, and the sensitivity of pH assay is 73 mV/pH. Notably, as variation of sample pH has impact on electrochemical analysis, the pH-related parameter was introduced for calibration to diminish such interference. The developed tip sensor and the novel sensing strategy may open a new window for electrochemical technology and broaden its application in POCT.</span></p></div>","PeriodicalId":259,"journal":{"name":"Biosensors and Bioelectronics","volume":"193 ","pages":"Article 113534"},"PeriodicalIF":11.8000,"publicationDate":"2021-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.bios.2021.113534","citationCount":"24","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors and Bioelectronics","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0956566321005716","RegionNum":1,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/7/27 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 24

Abstract

Electrochemical sensors have shown great advantage and application potential in point-of-care testing (POCT) related scenarios. However, some fatal problems plague its widespread utilization, which include the susceptibility of sensors to interference in real samples (e.g. pH), the contradiction between the limited objects detectable for most sensors and the requirement of multi-target analysis in most cases, and the complicated procedures in sensor preparation as well as in routine use. This paper contributed a tip-like electrochemical sensor prototype. By integrated with a commercial pipettor, it fulfilled semi-automatic assay procedure of sampling, detection and rinsing, thus saving operational time and manual work. The tip sensor owns the property of simple fabrication and is free from any modification of extra bio/chem materials. Moreover, built on multiple electrochemical signal outputs including open circuit potential, peak current and potential of specific electrochemical reaction, this work established a novel multi-component sensing strategy, wherein detection of uric acid (UA), urea and pH in urine samples was realized by using one single working electrode. The detection range for the above targets is 5.0~600 μM for UA, 4.0~8.0 for pH and 0.5~7.0 mM for urea with the detection limits (S/N = 3) of 0.05 μM for UA and 5.4 μM for urea, and the sensitivity of pH assay is 73 mV/pH. Notably, as variation of sample pH has impact on electrochemical analysis, the pH-related parameter was introduced for calibration to diminish such interference. The developed tip sensor and the novel sensing strategy may open a new window for electrochemical technology and broaden its application in POCT.

用于尿液多组分检测的集成手持式电化学传感器
电化学传感器在与护理点检测(POCT)相关的场景中显示出巨大的优势和应用潜力。然而,一些致命的问题困扰着它的广泛应用,包括传感器对实际样品(如pH)的干扰敏感性,大多数传感器可检测的有限对象与大多数情况下多目标分析要求之间的矛盾,以及传感器制备和日常使用的复杂程序。本文提出了一种针尖状电化学传感器原型。通过与商用移液器集成,实现了取样、检测和冲洗的半自动分析程序,从而节省了操作时间和人工。尖端传感器具有制作简单的特点,不需要任何额外的生物/化学材料的修饰。此外,基于开路电位、峰值电流和特定电化学反应电位等多种电化学信号输出,本工作建立了一种新的多组分传感策略,通过一个工作电极实现尿液样品中尿酸、尿素和pH的检测。检测范围UA为5.0~600 μM, pH为4.0~8.0 μM,尿素为0.5~7.0 mM,检测限(S/N = 3) UA为0.05 μM,尿素为5.4 μM, pH法灵敏度为73 mV/pH。值得注意的是,由于样品pH的变化对电化学分析有影响,因此引入pH相关参数进行校准以减少这种干扰。所开发的尖端传感器和新型传感策略为电化学技术打开了一扇新的窗口,拓宽了其在POCT中的应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Biosensors and Bioelectronics
Biosensors and Bioelectronics 工程技术-电化学
CiteScore
20.80
自引率
7.10%
发文量
1006
审稿时长
29 days
期刊介绍: Biosensors & Bioelectronics, along with its open access companion journal Biosensors & Bioelectronics: X, is the leading international publication in the field of biosensors and bioelectronics. It covers research, design, development, and application of biosensors, which are analytical devices incorporating biological materials with physicochemical transducers. These devices, including sensors, DNA chips, electronic noses, and lab-on-a-chip, produce digital signals proportional to specific analytes. Examples include immunosensors and enzyme-based biosensors, applied in various fields such as medicine, environmental monitoring, and food industry. The journal also focuses on molecular and supramolecular structures for enhancing device performance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书