Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model.
Jaime Landman, Kurt Kerbl, Jamil Rehman, Cassio Andreoni, Peter A Humphrey, William Collyer, Ephrem Olweny, Chandru Sundaram, Ralph V Clayman
{"title":"Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model.","authors":"Jaime Landman, Kurt Kerbl, Jamil Rehman, Cassio Andreoni, Peter A Humphrey, William Collyer, Ephrem Olweny, Chandru Sundaram, Ralph V Clayman","doi":"10.1097/01.ju.0000045160.87700.32","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>We assessed the usefulness of the LigaSure (Valleylab, Boulder, Colorado) vessel sealing system for vascular control during laparoscopic surgery and compared it with other available hemostatic modalities.</p><p><strong>Materials and methods: </strong>A total of 31 domestic pigs were divided into 5 groups. In groups 1 and 2 the vessel sealing system was compared with titanium clips and Endo-GIA (United States Surgical, Stamford, Connecticut) staples. In group 3 the vessel sealing system was compared with standard Klepinger (Karl Storz, Culver City, California) bipolar forceps. In group 4 the harmonic scalpel and Trimax (United States Surgical) bipolar forceps were compared. In group 5 in vivo laparoscopic application of the vessel sealing system was evaluated.</p><p><strong>Results: </strong>The 5 mm. laparoscopic vessel sealing system sealed arteries up to 6 mm. and veins up to 12 mm. in diameter at supraphysiological bursting pressure. We evaluated 13 arteries with a diameter of 6 mm. or less at a mean bursting pressure of 662 mm. Hg (range 363 to 1,985) and 11 veins with a diameter of 12 mm. or less with a mean bursting pressure of 233 mm. Hg (range 63 to 440). Collateral tissue damage extended 1 to 3 mm. from the application site. Standard bipolar energy with Klepinger and Trimax forceps was less reliable and in some cases vessel sealing could not be accurately assessed before vessel division. Collateral tissue injury was 1 to 6 mm. The harmonic scalpel did not reliably seal vessels larger than 3 mm. but resulted in the least acute collateral tissue injury of 0 to 1 mm.</p><p><strong>Conclusions: </strong>In the porcine model the LigaSure system is a viable option for laparoscopic management of arteries up to 6 mm. and veins up to 12 mm. in diameter.</p>","PeriodicalId":17471,"journal":{"name":"Journal of Urology","volume":"169 2","pages":"697-700"},"PeriodicalIF":6.8000,"publicationDate":"2003-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Urology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/01.ju.0000045160.87700.32","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: We assessed the usefulness of the LigaSure (Valleylab, Boulder, Colorado) vessel sealing system for vascular control during laparoscopic surgery and compared it with other available hemostatic modalities.
Materials and methods: A total of 31 domestic pigs were divided into 5 groups. In groups 1 and 2 the vessel sealing system was compared with titanium clips and Endo-GIA (United States Surgical, Stamford, Connecticut) staples. In group 3 the vessel sealing system was compared with standard Klepinger (Karl Storz, Culver City, California) bipolar forceps. In group 4 the harmonic scalpel and Trimax (United States Surgical) bipolar forceps were compared. In group 5 in vivo laparoscopic application of the vessel sealing system was evaluated.
Results: The 5 mm. laparoscopic vessel sealing system sealed arteries up to 6 mm. and veins up to 12 mm. in diameter at supraphysiological bursting pressure. We evaluated 13 arteries with a diameter of 6 mm. or less at a mean bursting pressure of 662 mm. Hg (range 363 to 1,985) and 11 veins with a diameter of 12 mm. or less with a mean bursting pressure of 233 mm. Hg (range 63 to 440). Collateral tissue damage extended 1 to 3 mm. from the application site. Standard bipolar energy with Klepinger and Trimax forceps was less reliable and in some cases vessel sealing could not be accurately assessed before vessel division. Collateral tissue injury was 1 to 6 mm. The harmonic scalpel did not reliably seal vessels larger than 3 mm. but resulted in the least acute collateral tissue injury of 0 to 1 mm.
Conclusions: In the porcine model the LigaSure system is a viable option for laparoscopic management of arteries up to 6 mm. and veins up to 12 mm. in diameter.
期刊介绍:
The Official Journal of the American Urological Association (AUA), and the most widely read and highly cited journal in the field, The Journal of Urology® brings solid coverage of the clinically relevant content needed to stay at the forefront of the dynamic field of urology. This premier journal presents investigative studies on critical areas of research and practice, survey articles providing short condensations of the best and most important urology literature worldwide, and practice-oriented reports on significant clinical observations.