Effect of sample preparation and pH-mediated sample stacking on the analysis of multiplexed short tandem repeats by capillary electrophoresis.

Federica Crivellente, Bruce R McCord
{"title":"Effect of sample preparation and pH-mediated sample stacking on the analysis of multiplexed short tandem repeats by capillary electrophoresis.","authors":"Federica Crivellente,&nbsp;Bruce R McCord","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>An amplification system was used in this study to evaluate the effect of sample preparation and its injection on the electrophoretic separation by capillary electrophoresis using a commercially available capillary electrophoresis instrument. The effect of dilution of amplified samples in water and in different sources of formamide (with conductivity values ranging from 47 to 1000 microS) was evaluated, as was contamination of the sample with high DNA concentrations or buffer salts. Although resolution remained constant in the different solvents tested, the sensitivity increased in samples diluted in water and high-purity formamide. An on-column sample preconcentration method for capillary-based DNA analysis was evaluated to increase the sensitivity of low-quality samples. This technique, pH-mediated sample stacking, is based on the injection of NaOH immediately before sample injection: A neutralization reaction occurs between OH- and tris+ ions so that a low-conductivity zone is created at the head of the capillary. DNA fragments are concentrated at the front of this zone. Using coated capillaries with hydroxycellulose 2% (MW 250,000) as a separation matrix, an improvement in sensitivity was detected in all the solvents studied. The gain in sensitivity was higher for more conductive solvents, and was not correlated with the size of the DNA fragments.</p>","PeriodicalId":15060,"journal":{"name":"Journal of capillary electrophoresis and microchip technology","volume":"7 3-4","pages":"73-80"},"PeriodicalIF":0.0000,"publicationDate":"2002-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of capillary electrophoresis and microchip technology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

An amplification system was used in this study to evaluate the effect of sample preparation and its injection on the electrophoretic separation by capillary electrophoresis using a commercially available capillary electrophoresis instrument. The effect of dilution of amplified samples in water and in different sources of formamide (with conductivity values ranging from 47 to 1000 microS) was evaluated, as was contamination of the sample with high DNA concentrations or buffer salts. Although resolution remained constant in the different solvents tested, the sensitivity increased in samples diluted in water and high-purity formamide. An on-column sample preconcentration method for capillary-based DNA analysis was evaluated to increase the sensitivity of low-quality samples. This technique, pH-mediated sample stacking, is based on the injection of NaOH immediately before sample injection: A neutralization reaction occurs between OH- and tris+ ions so that a low-conductivity zone is created at the head of the capillary. DNA fragments are concentrated at the front of this zone. Using coated capillaries with hydroxycellulose 2% (MW 250,000) as a separation matrix, an improvement in sensitivity was detected in all the solvents studied. The gain in sensitivity was higher for more conductive solvents, and was not correlated with the size of the DNA fragments.

样品制备和ph介导的样品堆积对毛细管电泳分析多路短串联重复序列的影响。
本研究采用一种扩增系统,在市售毛细管电泳仪上评价样品制备及其进样对毛细管电泳电泳分离的影响。评估了在水中和不同来源的甲酰胺(电导率值范围从47到1000微秒)中稀释放大样品的效果,以及用高DNA浓度或缓冲盐污染样品的效果。虽然在不同的溶剂中分辨率保持不变,但在水和高纯度甲酰胺中稀释的样品中灵敏度增加。评估了毛细管DNA分析的柱上样品预浓缩方法,以提高低质量样品的灵敏度。这种ph介导的样品堆积技术是基于在样品注入之前立即注入NaOH: OH-和tris+离子之间发生中和反应,从而在毛细管头部形成低电导率区。DNA片段集中在这个区域的前部。用2%羟纤维素(MW 250000)包膜毛细管作为分离基质,在所有溶剂中检测到灵敏度的提高。灵敏度的增益对更导电的溶剂更高,并且与DNA片段的大小无关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信