Mingxuan Peng , Shaoyu Lin , Zhenbin Lin , Delun Zheng , Yibing Song , Fushen Lu , Yaowen Chen , Wenhua Gao
{"title":"Rationally constructed ZnCdS-HDCs@In2S3-HNRs double-hollow heterojunction with promoted light capture capability for photoelectrochemical biosensing","authors":"Mingxuan Peng , Shaoyu Lin , Zhenbin Lin , Delun Zheng , Yibing Song , Fushen Lu , Yaowen Chen , Wenhua Gao","doi":"10.1016/j.bios.2021.113957","DOIUrl":null,"url":null,"abstract":"<div><p><span><span>The construction of novel heterojunction is regarded as an operative scheme to promote the transport of </span>photogenerated carriers<span> and reduce electron-hole pair recombination to enhance the photoelectrochemical (PEC) performances. Herein, ZnCdS hollow dodecahedral nanocages (ZnCdS-HDCs) and In</span></span><sub>2</sub>S<sub>3</sub><span> hollow nanorods (In</span><sub>2</sub>S<sub>3</sub><span><span>-HNRs), which were derived from two different of metal-organic frameworks (MOFs) by solvothermal sulfidation method and were constructed an original double-hollow </span>heterostructure ZnCdS-HDCs@In</span><sub>2</sub>S<sub>3</sub>-HNRs. The intrinsic mechanism of In<sub>2</sub>S<sub>3</sub><span>-HNRs benefiting from unique morphology to boost the photochemical properties under visible light irradiation was illustrated. Meanwhile, the mechanism of the novel type II heterojunction with staggered matching levels was revealed, which could effectively restrict electron-hole pair reassociation separation, and accelerated charge separation and transfer. Therefore, based on the excellent PEC performance of ZnCdS- HDCs@In</span><sub>2</sub>S<sub>3</sub><span>-HNRs double-hollow heterostructure, a signal-off PEC biosensor platform without labeled was constructed for the detection of CA15-3, which manifested acceptable specificity, reproducibility and stability. Additionally, the expected PEC biosensors showed a linear response range from 1.0 × 10</span><sup>−5</sup> to 10 U·mL<sup>−1</sup> in addition to an ultralow detection limit of 3.78 × 10<sup>−6</sup> U·mL<sup>−1</sup>. This study innovatively constructed and prepared a new double-hollow heterojunction material with superior PEC nature for the application of PEC biosensing, which exhibits a broad application prospect.</p></div>","PeriodicalId":259,"journal":{"name":"Biosensors and Bioelectronics","volume":"201 ","pages":"Article 113957"},"PeriodicalIF":11.8000,"publicationDate":"2022-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors and Bioelectronics","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0956566321009945","RegionNum":1,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/3 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 12
Abstract
The construction of novel heterojunction is regarded as an operative scheme to promote the transport of photogenerated carriers and reduce electron-hole pair recombination to enhance the photoelectrochemical (PEC) performances. Herein, ZnCdS hollow dodecahedral nanocages (ZnCdS-HDCs) and In2S3 hollow nanorods (In2S3-HNRs), which were derived from two different of metal-organic frameworks (MOFs) by solvothermal sulfidation method and were constructed an original double-hollow heterostructure ZnCdS-HDCs@In2S3-HNRs. The intrinsic mechanism of In2S3-HNRs benefiting from unique morphology to boost the photochemical properties under visible light irradiation was illustrated. Meanwhile, the mechanism of the novel type II heterojunction with staggered matching levels was revealed, which could effectively restrict electron-hole pair reassociation separation, and accelerated charge separation and transfer. Therefore, based on the excellent PEC performance of ZnCdS- HDCs@In2S3-HNRs double-hollow heterostructure, a signal-off PEC biosensor platform without labeled was constructed for the detection of CA15-3, which manifested acceptable specificity, reproducibility and stability. Additionally, the expected PEC biosensors showed a linear response range from 1.0 × 10−5 to 10 U·mL−1 in addition to an ultralow detection limit of 3.78 × 10−6 U·mL−1. This study innovatively constructed and prepared a new double-hollow heterojunction material with superior PEC nature for the application of PEC biosensing, which exhibits a broad application prospect.
期刊介绍:
Biosensors & Bioelectronics, along with its open access companion journal Biosensors & Bioelectronics: X, is the leading international publication in the field of biosensors and bioelectronics. It covers research, design, development, and application of biosensors, which are analytical devices incorporating biological materials with physicochemical transducers. These devices, including sensors, DNA chips, electronic noses, and lab-on-a-chip, produce digital signals proportional to specific analytes. Examples include immunosensors and enzyme-based biosensors, applied in various fields such as medicine, environmental monitoring, and food industry. The journal also focuses on molecular and supramolecular structures for enhancing device performance.