A custom designed system to measure corticospinal tract jitter

Marjan Mihelin , Rajka M Liscic
{"title":"A custom designed system to measure corticospinal tract jitter","authors":"Marjan Mihelin ,&nbsp;Rajka M Liscic","doi":"10.1016/S0924-980X(97)00079-9","DOIUrl":null,"url":null,"abstract":"<div><p>Typical latency of an individual limb muscle response to magnetic or electric stimulation of the human cortex is in the range of 10–50 ms. For the latency variability, i.e., jitter studies, a resolution of at least 20 <em>μ</em><span>s is needed. Commercially available EMG equipment needs custom-designed upgrading to allow for such studies. Two solutions were designed: (i) a hardware unit allowing an adjustable delay of data acquisition after the delivered stimuli; and (ii) diverting of the amplified biological signal and the EMG equipment trigger to an external computer equipped with an analogue-to-digital conversion (ADC) module. Custom-designed software made fast ADC possible during the whole period of data acquisition. Both concepts were applied to a Vickers Medical Mystro electromyograph, and have been successfully used in the Ljubljana (Slovenia) Institute of Clinical Neurophysiology for the last 2 years.</span></p></div>","PeriodicalId":100400,"journal":{"name":"Electroencephalography and Clinical Neurophysiology/Electromyography and Motor Control","volume":"109 2","pages":"Pages 194-197"},"PeriodicalIF":0.0000,"publicationDate":"1998-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0924-980X(97)00079-9","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electroencephalography and Clinical Neurophysiology/Electromyography and Motor Control","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0924980X97000799","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Typical latency of an individual limb muscle response to magnetic or electric stimulation of the human cortex is in the range of 10–50 ms. For the latency variability, i.e., jitter studies, a resolution of at least 20 μs is needed. Commercially available EMG equipment needs custom-designed upgrading to allow for such studies. Two solutions were designed: (i) a hardware unit allowing an adjustable delay of data acquisition after the delivered stimuli; and (ii) diverting of the amplified biological signal and the EMG equipment trigger to an external computer equipped with an analogue-to-digital conversion (ADC) module. Custom-designed software made fast ADC possible during the whole period of data acquisition. Both concepts were applied to a Vickers Medical Mystro electromyograph, and have been successfully used in the Ljubljana (Slovenia) Institute of Clinical Neurophysiology for the last 2 years.

一个定制设计的系统来测量皮质脊髓束抖动
个体肢体肌肉对人体皮层的磁或电刺激反应的典型潜伏期在10-50毫秒之间。对于延迟可变性,即抖动研究,至少需要20 μs的分辨率。商用肌电图设备需要定制设计升级,以允许此类研究。设计了两种解决方案:(i)一个硬件单元,允许在传递刺激后可调的数据采集延迟;以及(ii)将放大的生物信号和肌电图设备触发器转移到配备模数转换(ADC)模块的外部计算机。定制设计的软件使整个数据采集过程中的快速ADC成为可能。这两个概念都应用于维克斯医学Mystro肌电图,并已成功地在卢布尔雅那(斯洛文尼亚)临床神经生理学研究所使用了2年。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信