[Speed S sensitivity of film-screen systems and mode of action of different automatic illumination in general practice. I: Film-screen systems].

Aktuelle Radiologie Pub Date : 1997-09-01
C Blendl, M Kondmann, J Müller
{"title":"[Speed S sensitivity of film-screen systems and mode of action of different automatic illumination in general practice. I: Film-screen systems].","authors":"C Blendl,&nbsp;M Kondmann,&nbsp;J Müller","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A new test procedure is presented to check the correspondence between various screen-film systems (SFS) with the specification of the manufacturer in respect to the speed S according to DIN 6867-1 or rather which dose K is required for the SFS in dependence on the X-ray tube voltage (kV) to give the net density Dn = 1.00, it is based on measurements of dose and density using on X-ray equipment with water as an absorber and scatter test tool. The characteristic curves of the automatic exposure control (AEC) can be recorded and compared with those of SFS, i.e., how is the dose K in the image-receptor-plane regulated by the AEC in dependence on different radiation qualities. It is also possible to check the modes of operation of SFS and AEC with sufficient accuracy but lower time and energy requirements. The consequences of finding the right values to test the X-ray equipment under DIN 6868-50/-3 and for constancy-testing according to DIN 6868-3 are discussed.</p>","PeriodicalId":76986,"journal":{"name":"Aktuelle Radiologie","volume":"7 5","pages":"288-94"},"PeriodicalIF":0.0000,"publicationDate":"1997-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Aktuelle Radiologie","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A new test procedure is presented to check the correspondence between various screen-film systems (SFS) with the specification of the manufacturer in respect to the speed S according to DIN 6867-1 or rather which dose K is required for the SFS in dependence on the X-ray tube voltage (kV) to give the net density Dn = 1.00, it is based on measurements of dose and density using on X-ray equipment with water as an absorber and scatter test tool. The characteristic curves of the automatic exposure control (AEC) can be recorded and compared with those of SFS, i.e., how is the dose K in the image-receptor-plane regulated by the AEC in dependence on different radiation qualities. It is also possible to check the modes of operation of SFS and AEC with sufficient accuracy but lower time and energy requirements. The consequences of finding the right values to test the X-ray equipment under DIN 6868-50/-3 and for constancy-testing according to DIN 6868-3 are discussed.

一般情况下,膜屏系统的速度、灵敏度和不同自动照明的作用方式。电影-屏幕系统]。
提出了一种新的测试程序,以检查各种屏蔽膜系统(SFS)与制造商的规格之间的对应关系,根据DIN 6867-1的速度S,或者更确切地说,SFS所需的剂量K取决于x射线管电压(kV),以给出净密度Dn = 1.00,它是基于在x射线设备上使用水作为吸收剂和散射测试工具的剂量和密度测量。记录自动曝光控制(AEC)的特性曲线,并与SFS的特性曲线进行比较,即不同的辐射质量下,自动曝光控制如何调节图像受体平面上的剂量K。还可以以足够的精度检查SFS和AEC的操作模式,但时间和能量要求较低。讨论了根据DIN 6868-50/-3和DIN 6868-3进行恒常测试时找到正确值的后果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信