[Studies of image quality and dose in digital subtraction angiography].

Aktuelle Radiologie Pub Date : 1997-07-01
H Heckmann, K F Kamm, S Vetter, E P Strecker, H P Busch
{"title":"[Studies of image quality and dose in digital subtraction angiography].","authors":"H Heckmann,&nbsp;K F Kamm,&nbsp;S Vetter,&nbsp;E P Strecker,&nbsp;H P Busch","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Methods: </strong>The dose needed for high image quality in l.a. DSA, was determined by investigation of the necessary relationship between dose and image quality. This method is based on measurements of the signal-to-noise ratio and of the contrast-detail detectability. It has been tested on two different systems (Philips integris V3000, Philips Diagnost 97).</p><p><strong>Results: </strong>Our measurements prove that an image intensifier entrance dose of 1.1 microGy (image intensifier diameter 38 cm) is sufficient for high image quality in DSA. An increased dose value does not lead to an improvement in image information. For details larger than the pixel size the 512 matrix produces a higher signal-to-noise ratio with a higher contrast-detail detectability, whereas higher spatial resolution results by the use of a 1024 matrix. In rotational angiography, high image quality can be achieved at an image intensifier entrance dose of 1.1 microGy. In contrast to sequences without rotation, image quality is decreased through movement unsharpness. As the maximum exposure time 25 ms should be selected. The use of a 1024 matrix does not lead to a better spatial resolution in rotational angiography.</p>","PeriodicalId":76986,"journal":{"name":"Aktuelle Radiologie","volume":"7 4","pages":"205-11"},"PeriodicalIF":0.0000,"publicationDate":"1997-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Aktuelle Radiologie","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Methods: The dose needed for high image quality in l.a. DSA, was determined by investigation of the necessary relationship between dose and image quality. This method is based on measurements of the signal-to-noise ratio and of the contrast-detail detectability. It has been tested on two different systems (Philips integris V3000, Philips Diagnost 97).

Results: Our measurements prove that an image intensifier entrance dose of 1.1 microGy (image intensifier diameter 38 cm) is sufficient for high image quality in DSA. An increased dose value does not lead to an improvement in image information. For details larger than the pixel size the 512 matrix produces a higher signal-to-noise ratio with a higher contrast-detail detectability, whereas higher spatial resolution results by the use of a 1024 matrix. In rotational angiography, high image quality can be achieved at an image intensifier entrance dose of 1.1 microGy. In contrast to sequences without rotation, image quality is decreased through movement unsharpness. As the maximum exposure time 25 ms should be selected. The use of a 1024 matrix does not lead to a better spatial resolution in rotational angiography.

数字减影血管造影中图像质量和剂量的研究。
方法:通过探讨剂量与成像质量的必然关系,确定高成像质量所需的剂量。该方法基于信噪比和对比度细节可检测性的测量。它已在两种不同的系统(Philips integris V3000, Philips Diagnost 97)上进行了测试。结果:我们的测量证明,图像增强器的入口剂量为1.1 microGy(图像增强器直径38 cm)足以获得高图像质量的DSA。增加的剂量值不会导致图像信息的改善。对于大于像素大小的细节,512矩阵产生更高的信噪比和更高的对比度细节可检测性,而使用1024矩阵产生更高的空间分辨率。在旋转血管造影中,图像增强器的入口剂量为1.1微gy时可以获得高图像质量。与没有旋转的序列相比,由于运动不清晰,图像质量下降。最大曝光时间应选择25毫秒。在旋转血管造影中,使用1024矩阵并不能获得更好的空间分辨率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信