{"title":"Reducing the levels of formaldehyde exposure in gross anatomy laboratories.","authors":"R Coleman","doi":"10.1002/ar.1092430417","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>A method is described in which formaldehyde levels are greatly reduced in our gross anatomy laboratory in order to comply with increasingly severe safety and health regulations.</p><p><strong>Methods: </strong>A novel type of dissection \"bed\" has been introduced which incorporates an internal motor that causes a downflow of formaldehyde-rich vapors, which are absorbed by a replaceable active carbon filtration system.</p><p><strong>Results: </strong>Use of the new dissection \"beds\" has resulted in the recirculated air being virtually formaldehyde-free. Formaldehyde vapor levels in our gross anatomy laboratory have been greatly reduced and are typically in the range of 0.03-0.09 ppm.</p><p><strong>Conclusions: </strong>The new system allows us to comply with safety and health regulations and provide a dissection room with an excellent working environment.</p>","PeriodicalId":50793,"journal":{"name":"Anatomical Record","volume":"243 4","pages":"531-3"},"PeriodicalIF":0.0000,"publicationDate":"1995-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/ar.1092430417","citationCount":"35","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anatomical Record","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/ar.1092430417","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Agricultural and Biological Sciences","Score":null,"Total":0}
引用次数: 35
Abstract
Background: A method is described in which formaldehyde levels are greatly reduced in our gross anatomy laboratory in order to comply with increasingly severe safety and health regulations.
Methods: A novel type of dissection "bed" has been introduced which incorporates an internal motor that causes a downflow of formaldehyde-rich vapors, which are absorbed by a replaceable active carbon filtration system.
Results: Use of the new dissection "beds" has resulted in the recirculated air being virtually formaldehyde-free. Formaldehyde vapor levels in our gross anatomy laboratory have been greatly reduced and are typically in the range of 0.03-0.09 ppm.
Conclusions: The new system allows us to comply with safety and health regulations and provide a dissection room with an excellent working environment.