[Observations and considerations on fetal risk by umbilical cord entanglement].

V M Roemer, S Kortüm-Roemer
{"title":"[Observations and considerations on fetal risk by umbilical cord entanglement].","authors":"V M Roemer,&nbsp;S Kortüm-Roemer","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Unlabelled: </strong>Mean actual pH-values in umbilical arterial (UA) and venous (UV) blood as well as mean AV-pH-differences (AVD-pH) were computed for individual Apgar-scores (1 min) in a sample of 10,580 term neonates, which were born vaginally from vertex position. The newborns of the study group showed all different kinds of cord entanglements (CE, N = 3430); neonates without CE were used as controls (N = 7144). In addition infants of the study group were attributed to two different birth weight-centile groups: < 25. and > 75. percentile.</p><p><strong>Results: </strong>In the study group mean AVD-pH-values in individual Apgar-scores showed a significant (P < 10(-5)) increase when compared with controls. The numerical value of AVD-pH seems to be a function of the clinical condition of the newborn: maximum value (mean = 0.113) was reached at Apgar 7; increasing neonatal distress was accompanied by low AVD-pH-values. This phenomenon was due to a decrease of actual pH in UA-blood and an increase in UV-blood; the latter was statistically feasible (P = 0.025) only in neonates with Apgar 8. AVD-pH-values of neonates above the 75. weight-centile showed a different reaction-pattern in individual Apgar-scores when compared with infants below the 25. centile: They remain constant or are slightly increased. We concluded, that blood-flow reduction in the umbilical vessels leads to a flow-dependent improvement of fetal pCO2-excretion at the placental level, which counteracts the developing metabolic fetal acidosis.(ABSTRACT TRUNCATED AT 250 WORDS)</p>","PeriodicalId":23919,"journal":{"name":"Zeitschrift fur Geburtshilfe und Perinatologie","volume":"197 1","pages":"20-6"},"PeriodicalIF":0.0000,"publicationDate":"1993-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zeitschrift fur Geburtshilfe und Perinatologie","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Unlabelled: Mean actual pH-values in umbilical arterial (UA) and venous (UV) blood as well as mean AV-pH-differences (AVD-pH) were computed for individual Apgar-scores (1 min) in a sample of 10,580 term neonates, which were born vaginally from vertex position. The newborns of the study group showed all different kinds of cord entanglements (CE, N = 3430); neonates without CE were used as controls (N = 7144). In addition infants of the study group were attributed to two different birth weight-centile groups: < 25. and > 75. percentile.

Results: In the study group mean AVD-pH-values in individual Apgar-scores showed a significant (P < 10(-5)) increase when compared with controls. The numerical value of AVD-pH seems to be a function of the clinical condition of the newborn: maximum value (mean = 0.113) was reached at Apgar 7; increasing neonatal distress was accompanied by low AVD-pH-values. This phenomenon was due to a decrease of actual pH in UA-blood and an increase in UV-blood; the latter was statistically feasible (P = 0.025) only in neonates with Apgar 8. AVD-pH-values of neonates above the 75. weight-centile showed a different reaction-pattern in individual Apgar-scores when compared with infants below the 25. centile: They remain constant or are slightly increased. We concluded, that blood-flow reduction in the umbilical vessels leads to a flow-dependent improvement of fetal pCO2-excretion at the placental level, which counteracts the developing metabolic fetal acidosis.(ABSTRACT TRUNCATED AT 250 WORDS)

[脐带缠绕对胎儿风险的观察与思考]。
未标记:计算10,580例足月新生儿的apgar评分(1分钟)的平均实际ph值(UA)和静脉(UV)血以及平均av - ph值差异(AVD-pH),这些新生儿均为经阴道从顶点位置出生。研究组新生儿出现不同类型脐带缠结(CE, N = 3430);无CE的新生儿作为对照组(N = 7144)。此外,研究组的婴儿被归为两个不同的出生体重百分位组:< 25。> 75。百分位。结果:与对照组相比,研究组个体apgar评分的avd - ph均值显著升高(P < 10(-5))。AVD-pH的数值似乎是新生儿临床状况的函数:在Apgar 7时达到最大值(平均值= 0.113);新生儿窘迫加重伴有低avd - ph值。这种现象是由于紫外线血的实际pH值降低而紫外线血的实际pH值增加;后者仅在Apgar为8的新生儿中具有统计学意义(P = 0.025)。新生儿avd - ph值高于75。与25岁以下的婴儿相比,体重百分位的婴儿在个体apgar评分中表现出不同的反应模式。百分位:它们保持不变或略有增加。我们得出结论,脐带血管血流减少导致胎盘水平胎儿pco2排泄的血流依赖性改善,从而抵消正在发生的代谢性胎儿酸中毒。(摘要删节250字)
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信