Comparison of flame ionization and inductively coupled plasma mass spectrometry for the detection of organometallics separated by capillary supercritical fluid chromatography.
{"title":"Comparison of flame ionization and inductively coupled plasma mass spectrometry for the detection of organometallics separated by capillary supercritical fluid chromatography.","authors":"N P Vela, J A Caruso","doi":"10.1016/0021-9673(93)80150-7","DOIUrl":null,"url":null,"abstract":"<p><p>Organotin compounds are separated by capillary supercritical fluid chromatography (SFC) and a comparison of the detection by flame ionization (FID) and inductively coupled plasma mass spectrometry (ICP-MS) is presented. Resolution, detection limits, linear dynamic range and reproducibility are the parameters compared between SFC-FID and SFC-ICP-MS, for the detection of tri- and tetraorganotin compounds. The resolution obtained in the SFC-FID system is not always observed in SFC-ICP-MS. Degradation in resolution is due to fluctuations in transfer line temperature. Baseline resolution for the organotins considered is achieved in both systems by using a longer column. Detection limits (DLs) are calculated as 3 sigma/S, where sigma is the standard deviation of the blank signal and S is the slope of the calibration curve. Detection limits of 10.3, 12.5, 12.0 and 9.0 pg are obtained for tetrabutyltin, tributyltin chloride, triphenyltin chloride and tetraphenyltin, respectively, using SFC-FID. An improvement in detection limits of one order of magnitude is achieved by SFC-ICP-MS for the same organotins (0.26, 0.80, 0.57 and 0.20 pg, respectively). The relative standard deviations using SFC-FID for five 50-nl injections, containing 0.5 ng Sn, ranged from 3.2 to 6.4%. Using SFC-ICP-MS, five replicate injections of 0.05 ng Sn give R.S.D.s from 1.3 to 3.4%.</p>","PeriodicalId":15508,"journal":{"name":"Journal of chromatography","volume":"641 2","pages":"337-45"},"PeriodicalIF":0.0000,"publicationDate":"1993-07-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0021-9673(93)80150-7","citationCount":"25","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of chromatography","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/0021-9673(93)80150-7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 25
Abstract
Organotin compounds are separated by capillary supercritical fluid chromatography (SFC) and a comparison of the detection by flame ionization (FID) and inductively coupled plasma mass spectrometry (ICP-MS) is presented. Resolution, detection limits, linear dynamic range and reproducibility are the parameters compared between SFC-FID and SFC-ICP-MS, for the detection of tri- and tetraorganotin compounds. The resolution obtained in the SFC-FID system is not always observed in SFC-ICP-MS. Degradation in resolution is due to fluctuations in transfer line temperature. Baseline resolution for the organotins considered is achieved in both systems by using a longer column. Detection limits (DLs) are calculated as 3 sigma/S, where sigma is the standard deviation of the blank signal and S is the slope of the calibration curve. Detection limits of 10.3, 12.5, 12.0 and 9.0 pg are obtained for tetrabutyltin, tributyltin chloride, triphenyltin chloride and tetraphenyltin, respectively, using SFC-FID. An improvement in detection limits of one order of magnitude is achieved by SFC-ICP-MS for the same organotins (0.26, 0.80, 0.57 and 0.20 pg, respectively). The relative standard deviations using SFC-FID for five 50-nl injections, containing 0.5 ng Sn, ranged from 3.2 to 6.4%. Using SFC-ICP-MS, five replicate injections of 0.05 ng Sn give R.S.D.s from 1.3 to 3.4%.