Comparison of flame ionization and inductively coupled plasma mass spectrometry for the detection of organometallics separated by capillary supercritical fluid chromatography.

N P Vela, J A Caruso
{"title":"Comparison of flame ionization and inductively coupled plasma mass spectrometry for the detection of organometallics separated by capillary supercritical fluid chromatography.","authors":"N P Vela,&nbsp;J A Caruso","doi":"10.1016/0021-9673(93)80150-7","DOIUrl":null,"url":null,"abstract":"<p><p>Organotin compounds are separated by capillary supercritical fluid chromatography (SFC) and a comparison of the detection by flame ionization (FID) and inductively coupled plasma mass spectrometry (ICP-MS) is presented. Resolution, detection limits, linear dynamic range and reproducibility are the parameters compared between SFC-FID and SFC-ICP-MS, for the detection of tri- and tetraorganotin compounds. The resolution obtained in the SFC-FID system is not always observed in SFC-ICP-MS. Degradation in resolution is due to fluctuations in transfer line temperature. Baseline resolution for the organotins considered is achieved in both systems by using a longer column. Detection limits (DLs) are calculated as 3 sigma/S, where sigma is the standard deviation of the blank signal and S is the slope of the calibration curve. Detection limits of 10.3, 12.5, 12.0 and 9.0 pg are obtained for tetrabutyltin, tributyltin chloride, triphenyltin chloride and tetraphenyltin, respectively, using SFC-FID. An improvement in detection limits of one order of magnitude is achieved by SFC-ICP-MS for the same organotins (0.26, 0.80, 0.57 and 0.20 pg, respectively). The relative standard deviations using SFC-FID for five 50-nl injections, containing 0.5 ng Sn, ranged from 3.2 to 6.4%. Using SFC-ICP-MS, five replicate injections of 0.05 ng Sn give R.S.D.s from 1.3 to 3.4%.</p>","PeriodicalId":15508,"journal":{"name":"Journal of chromatography","volume":"641 2","pages":"337-45"},"PeriodicalIF":0.0000,"publicationDate":"1993-07-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0021-9673(93)80150-7","citationCount":"25","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of chromatography","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/0021-9673(93)80150-7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 25

Abstract

Organotin compounds are separated by capillary supercritical fluid chromatography (SFC) and a comparison of the detection by flame ionization (FID) and inductively coupled plasma mass spectrometry (ICP-MS) is presented. Resolution, detection limits, linear dynamic range and reproducibility are the parameters compared between SFC-FID and SFC-ICP-MS, for the detection of tri- and tetraorganotin compounds. The resolution obtained in the SFC-FID system is not always observed in SFC-ICP-MS. Degradation in resolution is due to fluctuations in transfer line temperature. Baseline resolution for the organotins considered is achieved in both systems by using a longer column. Detection limits (DLs) are calculated as 3 sigma/S, where sigma is the standard deviation of the blank signal and S is the slope of the calibration curve. Detection limits of 10.3, 12.5, 12.0 and 9.0 pg are obtained for tetrabutyltin, tributyltin chloride, triphenyltin chloride and tetraphenyltin, respectively, using SFC-FID. An improvement in detection limits of one order of magnitude is achieved by SFC-ICP-MS for the same organotins (0.26, 0.80, 0.57 and 0.20 pg, respectively). The relative standard deviations using SFC-FID for five 50-nl injections, containing 0.5 ng Sn, ranged from 3.2 to 6.4%. Using SFC-ICP-MS, five replicate injections of 0.05 ng Sn give R.S.D.s from 1.3 to 3.4%.

火焰电离与电感耦合等离子体质谱法检测毛细管超临界流体色谱分离的有机金属。
采用毛细管超临界流体色谱法(SFC)分离有机锡化合物,并比较了火焰电离法(FID)和电感耦合等离子体质谱法(ICP-MS)的检测效果。对SFC-FID和SFC-ICP-MS检测三、四有机锡化合物的分辨率、检出限、线性动态范围和重现性进行了比较。在SFC-FID系统中获得的分辨率在SFC-ICP-MS中并不总是观察到。分辨率的下降是由于传输线温度的波动。在两个系统中,通过使用更长的色谱柱来实现所考虑的有机化合物的基线分辨率。检测限(DLs)计算为3 sigma/S,其中sigma为空白信号的标准差,S为校准曲线的斜率。SFC-FID对四丁基锡、三丁基氯化锡、三苯基氯化锡和四苯基锡的检出限分别为10.3、12.5、12.0和9.0 pg。SFC-ICP-MS对相同有机苷的检出限提高了一个数量级(分别为0.26、0.80、0.57和0.20 pg)。用SFC-FID对5支含0.5 ng Sn的50-nl注射剂的相对标准偏差范围为3.2 ~ 6.4%。采用SFC-ICP-MS, 5次重复注射0.05 ng Sn,相对标准偏差为1.3 ~ 3.4%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信