M G Rosell, J Obiols, M J Berenguer, X Guardino, F López, J Brosa
{"title":"Determination of chlorinated insecticides in blood samples of agricultural workers.","authors":"M G Rosell, J Obiols, M J Berenguer, X Guardino, F López, J Brosa","doi":"10.1016/0021-9673(93)87023-f","DOIUrl":null,"url":null,"abstract":"<p><p>Lindane, aldrin and p,p'-DDT were determined in blood samples from 71 farmers by means of an analytical method which combines a direct whole-blood extraction with n-hexane and gas chromatography (GC)-electron-capture detection (ECD), using a capillary column, applied to the organic extract. This technique allowed the determination of pesticides at levels varying from 0.1 to 180 micrograms per l of blood, the detection limit for every pesticide being 0.1 microgram/l. GC-mass spectrometry was used to confirm the identity of each pesticide. The advantage of capillary column GC-ECD for pesticide determination is its sensitivity and high resolution, which makes it possible to separate pesticides from a complex n-hexane extract obtained in a very simple pretreatment of the blood sample, which is itself a very complex matrix.</p>","PeriodicalId":15508,"journal":{"name":"Journal of chromatography","volume":"655 1","pages":"151-4"},"PeriodicalIF":0.0000,"publicationDate":"1993-11-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0021-9673(93)87023-f","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of chromatography","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/0021-9673(93)87023-f","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15
Abstract
Lindane, aldrin and p,p'-DDT were determined in blood samples from 71 farmers by means of an analytical method which combines a direct whole-blood extraction with n-hexane and gas chromatography (GC)-electron-capture detection (ECD), using a capillary column, applied to the organic extract. This technique allowed the determination of pesticides at levels varying from 0.1 to 180 micrograms per l of blood, the detection limit for every pesticide being 0.1 microgram/l. GC-mass spectrometry was used to confirm the identity of each pesticide. The advantage of capillary column GC-ECD for pesticide determination is its sensitivity and high resolution, which makes it possible to separate pesticides from a complex n-hexane extract obtained in a very simple pretreatment of the blood sample, which is itself a very complex matrix.