Location of the electrical center of ventricular depolarization in rabbits.

R Lolov
{"title":"Location of the electrical center of ventricular depolarization in rabbits.","authors":"R Lolov","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>This is a study on the location of the ventricular depolarization center, carried out on fifteen healthy rabbits according to the method of Ritsema van Eck. It is established that the level of equivalent heart dipole coincides with the fourth or fifth intercostal space, but in some laboratory animals this level displays a lower positioning. The inference is reached that to secure correct application of Frank's lead system it is necessary to use a prompt and precision method for determination of the level in question in each individual case. Such a method has not been developed as yet. For the time being, the optimal solution of the problem could be accomplished through a lead system that is less sensitive to electrode positioning errors.</p>","PeriodicalId":7035,"journal":{"name":"Acta physiologica et pharmacologica Bulgarica","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1994-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta physiologica et pharmacologica Bulgarica","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This is a study on the location of the ventricular depolarization center, carried out on fifteen healthy rabbits according to the method of Ritsema van Eck. It is established that the level of equivalent heart dipole coincides with the fourth or fifth intercostal space, but in some laboratory animals this level displays a lower positioning. The inference is reached that to secure correct application of Frank's lead system it is necessary to use a prompt and precision method for determination of the level in question in each individual case. Such a method has not been developed as yet. For the time being, the optimal solution of the problem could be accomplished through a lead system that is less sensitive to electrode positioning errors.

家兔心室去极化电中心的定位。
本文采用Ritsema van Eck方法对15只健康家兔进行了心室去极化中心位置的研究。已经确定等效心脏偶极子的水平与第四或第五肋间隙重合,但在一些实验动物中,该水平显示出较低的位置。得出的结论是,为了确保正确应用弗兰克的铅系统,有必要使用一种快速和精确的方法来确定每个案例中的问题水平。这种方法至今还没有开发出来。目前,该问题的最佳解决方案可以通过对电极定位误差不太敏感的引线系统来实现。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信