Analysis of bone-composite interfacial strengths.

C M Davis, J F Shackelford
{"title":"Analysis of bone-composite interfacial strengths.","authors":"C M Davis,&nbsp;J F Shackelford","doi":"10.3109/10731198109117600","DOIUrl":null,"url":null,"abstract":"<p><p>The strength characteristics of the interface between bone and a bone/porous metal composite were analyzed. The metal was 316L stainless steel. The average tensile strength of bone spicules ingrown to the porous metal was 46.5 MPa. This compares to a control bone sample strength of 89.7 MPa. The difference could be due to bone location and bone immaturity. The overall intefacial tensile strength (9.59 MPa) is necessarily lower since the spicules cover only a fraction of the interfacial cross-section. The overall interfacial strength had a wide range of scatter (s = +/- 4.11 MPa). This was probably due to inherent variations in bone strength with location. A population of samples using porous metal with average pore diameters under 100 micrometers exhibited measurably lower tensile strengths.</p>","PeriodicalId":75597,"journal":{"name":"Biomaterials, medical devices, and artificial organs","volume":"9 1","pages":"47-55"},"PeriodicalIF":0.0000,"publicationDate":"1981-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10731198109117600","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomaterials, medical devices, and artificial organs","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/10731198109117600","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The strength characteristics of the interface between bone and a bone/porous metal composite were analyzed. The metal was 316L stainless steel. The average tensile strength of bone spicules ingrown to the porous metal was 46.5 MPa. This compares to a control bone sample strength of 89.7 MPa. The difference could be due to bone location and bone immaturity. The overall intefacial tensile strength (9.59 MPa) is necessarily lower since the spicules cover only a fraction of the interfacial cross-section. The overall interfacial strength had a wide range of scatter (s = +/- 4.11 MPa). This was probably due to inherent variations in bone strength with location. A population of samples using porous metal with average pore diameters under 100 micrometers exhibited measurably lower tensile strengths.

骨-复合材料界面强度分析。
分析了骨与骨/多孔金属复合材料界面的强度特性。金属是316L不锈钢。骨针状体向内生长的平均抗拉强度为46.5 MPa。相比之下,对照骨样品的强度为89.7兆帕。这种差异可能是由于骨骼的位置和骨骼的不成熟。由于针状体只覆盖了一小部分界面截面,因此整体界面抗拉强度(9.59 MPa)必然较低。整体界面强度具有较宽的散射范围(s = +/- 4.11 MPa)。这可能是由于骨强度随位置的固有变化。使用平均孔径在100微米以下的多孔金属的样品群体显示出可测量的较低的拉伸强度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信