A novel bulk optode for ultra-trace detection of antimony coupled with spectrophotometry in food and environmental samples

IF 4.1 Q1 CHEMISTRY, ANALYTICAL
Islam M.I. Moustafa , Alaa S. Amin , Eman Darwish
{"title":"A novel bulk optode for ultra-trace detection of antimony coupled with spectrophotometry in food and environmental samples","authors":"Islam M.I. Moustafa ,&nbsp;Alaa S. Amin ,&nbsp;Eman Darwish","doi":"10.1016/j.talo.2023.100197","DOIUrl":null,"url":null,"abstract":"<div><p>A novel bulk optode was modified for ultra-trace detection of antimony. The optode was synthesized by incorporating fabricated ionophore, 6-{4-(2,4-di-hydroxyphenyl)diazenyl)phenyl}-2-oxo-4-phenyl-1,2-dihydropyridine-3-carbo-nitrile (DDPODC), 3-octadecanoylimino-7-(diethyl‑amino)-1,2-benzophenoxa-zine (ETH5294) as a chromoionophore, sodium tetraphenyl borate (NaTPB) as an anionic additive, and dioctyladipate (DOA) as a plasticizer in a poly vinyl chloride (PVC) membrane. In determining Sb<sup>3+</sup>, various parameters were implemented. Spectrophotometric procedure (λ<sub>max</sub> of 661 nm) was applied to define Sb<sup>3+</sup> within optimal conditions. The optode has a wide range of 2.5 × 10<sup>−8</sup> to 4.0 × 10<sup>−5</sup> M Sb<sup>3+</sup> with the detection and quantification limits as low as 7.0 × 10<sup>−9</sup> and 2.4 × 10<sup>−8</sup> M, respectively. The response time of optode was 3.0 min, with a RSD% of 1.75% (for 2.0 × 10<sup>−5</sup> M, <em>n</em>=6). A 0.15 M HCl solution could be used to regenerate the optode. The interfering ions were studied. It was revealed that the optode was highly selective to Sb<sup>3+</sup> ions and had no significant response to common cations and anions. It can be appealed that the optode can specifically detect Sb<sup>3+</sup> ions. The optode was favorable applied to assess total antimony ions after reduction of Sb<sup>5+</sup> to Sb<sup>3+</sup> using potassium iodide and ascorbic acid as reducing agents in various water, food and biological samples.</p></div>","PeriodicalId":436,"journal":{"name":"Talanta Open","volume":"7 ","pages":"Article 100197"},"PeriodicalIF":4.1000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Talanta Open","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666831923000188","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 1

Abstract

A novel bulk optode was modified for ultra-trace detection of antimony. The optode was synthesized by incorporating fabricated ionophore, 6-{4-(2,4-di-hydroxyphenyl)diazenyl)phenyl}-2-oxo-4-phenyl-1,2-dihydropyridine-3-carbo-nitrile (DDPODC), 3-octadecanoylimino-7-(diethyl‑amino)-1,2-benzophenoxa-zine (ETH5294) as a chromoionophore, sodium tetraphenyl borate (NaTPB) as an anionic additive, and dioctyladipate (DOA) as a plasticizer in a poly vinyl chloride (PVC) membrane. In determining Sb3+, various parameters were implemented. Spectrophotometric procedure (λmax of 661 nm) was applied to define Sb3+ within optimal conditions. The optode has a wide range of 2.5 × 10−8 to 4.0 × 10−5 M Sb3+ with the detection and quantification limits as low as 7.0 × 10−9 and 2.4 × 10−8 M, respectively. The response time of optode was 3.0 min, with a RSD% of 1.75% (for 2.0 × 10−5 M, n=6). A 0.15 M HCl solution could be used to regenerate the optode. The interfering ions were studied. It was revealed that the optode was highly selective to Sb3+ ions and had no significant response to common cations and anions. It can be appealed that the optode can specifically detect Sb3+ ions. The optode was favorable applied to assess total antimony ions after reduction of Sb5+ to Sb3+ using potassium iodide and ascorbic acid as reducing agents in various water, food and biological samples.

Abstract Image

一种用于食品和环境样品中超痕量锑耦合分光光度法的新型大块光电二极管
对一种用于锑超痕量检测的块体光电二极管进行了改进。以6-{4-(2,4-二羟基苯基)二氮杂基苯基}-2-氧-4-苯基-1,2-二氢吡啶-3-碳腈(DDPODC)、3-十八烷氧基-7-(二乙基氨基)-1,2-二苯甲氧嘧啶锌(ETH5294)为显色离子载体、四苯基硼酸钠(NaTPB)为阴离子添加剂、二辛基二酸酯(DOA)为增塑剂,在聚氯乙烯(PVC)膜中合成了光电二极管。在测定Sb3+时,实现了各种参数。在最佳条件下,采用分光光度法(λmax为661 nm)测定Sb3+。该光电器件的Sb3+光谱范围为2.5 × 10−8 ~ 4.0 × 10−5 M,检测限和定量限分别低至7.0 × 10−9和2.4 × 10−8 M。光电二极管的响应时间为3.0 min, RSD%为1.75% (2.0 × 10−5 M, n=6)。0.15 M的HCl溶液可以再生光电器件。对干扰离子进行了研究。结果表明,该光电二极管对Sb3+离子有很高的选择性,而对常见的阳离子和阴离子没有明显的反应。值得注意的是,该光电器件可以特异性地检测Sb3+离子。在各种水、食品和生物样品中,以碘化钾和抗坏血酸为还原剂,将Sb5+还原为Sb3+后,该光电二极管可用于测定总锑离子。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Talanta Open
Talanta Open Chemistry-Analytical Chemistry
CiteScore
5.20
自引率
0.00%
发文量
86
审稿时长
49 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信