{"title":"Absolute intensity calibration of a grazing-incidence spectrograph in the wavelength region 10-120 Angstrom.","authors":"F J Morgan, A H Gabriel, M J Barton","doi":"10.1088/0022-3735/1/10/306","DOIUrl":null,"url":null,"abstract":"A method is described for determining the absolute sensitivity of a grazing-incidence spectrograph. This makes use of an x-ray source of discrete K-lines, the intensity of which is monitored by a flow proportional counter, acting as an absolute photon flux detector. Experimental results are given for Ilford Q2 emulsion used with a two-metre 600 lines per mm platinum coated blazed grating at an angle of incidence of 88°. The resultant curve compares well with a relative calibration obtained by using the radiation from a 335 MeV electron beam in a synchrotron.","PeriodicalId":16983,"journal":{"name":"Journal of Scientific Instruments","volume":"1 10","pages":"998-1002"},"PeriodicalIF":0.0000,"publicationDate":"1968-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1088/0022-3735/1/10/306","citationCount":"21","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Scientific Instruments","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/0022-3735/1/10/306","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 21

Abstract

A method is described for determining the absolute sensitivity of a grazing-incidence spectrograph. This makes use of an x-ray source of discrete K-lines, the intensity of which is monitored by a flow proportional counter, acting as an absolute photon flux detector. Experimental results are given for Ilford Q2 emulsion used with a two-metre 600 lines per mm platinum coated blazed grating at an angle of incidence of 88°. The resultant curve compares well with a relative calibration obtained by using the radiation from a 335 MeV electron beam in a synchrotron.
10-120埃波段掠入射光谱仪的绝对强度标定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信