Novel data-processing method for determining the activity size distribution of unattached radon progeny with multi-layer perceptron machine learning algorithm.
{"title":"Novel data-processing method for determining the activity size distribution of unattached radon progeny with multi-layer perceptron machine learning algorithm.","authors":"Duanyang Ma, Jinmin Yang, Lei Zhang","doi":"10.1016/j.apradiso.2026.113099","DOIUrl":null,"url":null,"abstract":"<p><p>The activity size distribution of unattached radon progeny is a critical parameter for calculating radon exposure dose conversion coefficient. To achieve accurate measurement of the activity size distribution of unattached radon progeny, a new data-processing method based on the Multi-Layer Perceptron (MLP) machine learning algorithm and a Graded Screen Array (GSA) system was proposed, and a series of comparison experiments and field measurements were carried out. Comparison experiment results based on simulated data demonstrate that the solutions obtained by the MLP algorithms exhibit smaller deviation than that of the traditional Expectation Maximization (EM) algorithm and Twomey algorithm, and no ambiguous solutions is existed for different MLP algorithms and different activity size distribution. Comparison experiments based on field measurement data show that traditional inversion algorithms tend to produce ambiguous solutions and suffer from non-convergence in iteration, and thus exhibit lower reliability than the MLP algorithm. More field measurement results show that the activity size distribution of unattached radon progeny indoors and outdoors exhibit a unimodal distribution generally. The average Activity Median Diameter (AMD) is 2.63 nm and the average Geometric Standard Deviation (GSD) is 1.64 for indoors, while the average AMD is 2.84 nm and GSD is 1.49 for outdoors. The phenomenon that the AMD increasing with the relative humidity is observed in high humidity environments.</p>","PeriodicalId":8096,"journal":{"name":"Applied Radiation and Isotopes","volume":"240 ","pages":"113099"},"PeriodicalIF":2.1000,"publicationDate":"2026-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Radiation and Isotopes","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1016/j.apradiso.2026.113099","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, INORGANIC & NUCLEAR","Score":null,"Total":0}
引用次数: 0
Abstract
The activity size distribution of unattached radon progeny is a critical parameter for calculating radon exposure dose conversion coefficient. To achieve accurate measurement of the activity size distribution of unattached radon progeny, a new data-processing method based on the Multi-Layer Perceptron (MLP) machine learning algorithm and a Graded Screen Array (GSA) system was proposed, and a series of comparison experiments and field measurements were carried out. Comparison experiment results based on simulated data demonstrate that the solutions obtained by the MLP algorithms exhibit smaller deviation than that of the traditional Expectation Maximization (EM) algorithm and Twomey algorithm, and no ambiguous solutions is existed for different MLP algorithms and different activity size distribution. Comparison experiments based on field measurement data show that traditional inversion algorithms tend to produce ambiguous solutions and suffer from non-convergence in iteration, and thus exhibit lower reliability than the MLP algorithm. More field measurement results show that the activity size distribution of unattached radon progeny indoors and outdoors exhibit a unimodal distribution generally. The average Activity Median Diameter (AMD) is 2.63 nm and the average Geometric Standard Deviation (GSD) is 1.64 for indoors, while the average AMD is 2.84 nm and GSD is 1.49 for outdoors. The phenomenon that the AMD increasing with the relative humidity is observed in high humidity environments.
期刊介绍:
Applied Radiation and Isotopes provides a high quality medium for the publication of substantial, original and scientific and technological papers on the development and peaceful application of nuclear, radiation and radionuclide techniques in chemistry, physics, biochemistry, biology, medicine, security, engineering and in the earth, planetary and environmental sciences, all including dosimetry. Nuclear techniques are defined in the broadest sense and both experimental and theoretical papers are welcome. They include the development and use of α- and β-particles, X-rays and γ-rays, neutrons and other nuclear particles and radiations from all sources, including radionuclides, synchrotron sources, cyclotrons and reactors and from the natural environment.
The journal aims to publish papers with significance to an international audience, containing substantial novelty and scientific impact. The Editors reserve the rights to reject, with or without external review, papers that do not meet these criteria.
Papers dealing with radiation processing, i.e., where radiation is used to bring about a biological, chemical or physical change in a material, should be directed to our sister journal Radiation Physics and Chemistry.