{"title":"Ultra-Low-Power Analog Front-End for Batteryless NFC Cyclic Voltammetry","authors":"Matheus Willian Sprotte;Pedro Bertemes Filho","doi":"10.1109/LSENS.2026.3731448","DOIUrl":null,"url":null,"abstract":"The continuous monitoring of biomarkers via wearable electrochemical sensors is often hindered by the power and form-factor constraints of traditional batteries. Passive near-field communication (NFC) technologies offer a highly viable batteryless alternative; however, integrating complex electroanalytical techniques, such as cyclic voltammetry (CV), into ultra-low-power system-on-chips (SoCs) remains a significant challenge due to the lack of dedicated hardware like digital-to-analog converters. This letter presents the design and constraint-emulated benchtop validation of a high-fidelity, ultra-low-power analog front-end (AFE) tailored specifically for the severe architectural constraints of passive NFC SoCs. By emulating the dual-supply architecture and the 2 MHz clock limit of the Texas Instruments RF430FRL153H transponder, a continuous staircase voltage sweep is synthesized via pulsewidth modulation smoothed by a dual-stage, low-pass <italic>RC</i> filter (<inline-formula><tex-math>$f_{c} = 10.24$</tex-math></inline-formula> Hz). Faradaic currents are acquired using a transimpedance amplifier topology constrained to a 1.5 V digital window. Benchtop validation using a 5 mM potassium ferricyanide redox probe on screen-printed electrodes captured distinct faradaic signatures. The proposed AFE was benchmarked against a commercial laboratory-grade potentiostat, demonstrating comparable electrochemical sensitivity and a reversibility ratio (<inline-formula><tex-math>$Q_{a}/Q_{c} = 1.039 \\pm 0.037$</tex-math></inline-formula>, <inline-formula><tex-math>$n=3$</tex-math></inline-formula>) closer to theoretical unity than the commercial reference (<inline-formula><tex-math>$0.766 \\pm 0.026$</tex-math></inline-formula>). These results confirm the architectural feasibility of executing precise CV under the constraints of passive NFC SoCs, with integration onto the target RF-harvested platform reserved for future work.","PeriodicalId":13014,"journal":{"name":"IEEE Sensors Letters","volume":"10 11","pages":"4504304-4504304"},"PeriodicalIF":2.4000,"publicationDate":"2026-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=11680015","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Sensors Letters","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11680015/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/9/4 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

The continuous monitoring of biomarkers via wearable electrochemical sensors is often hindered by the power and form-factor constraints of traditional batteries. Passive near-field communication (NFC) technologies offer a highly viable batteryless alternative; however, integrating complex electroanalytical techniques, such as cyclic voltammetry (CV), into ultra-low-power system-on-chips (SoCs) remains a significant challenge due to the lack of dedicated hardware like digital-to-analog converters. This letter presents the design and constraint-emulated benchtop validation of a high-fidelity, ultra-low-power analog front-end (AFE) tailored specifically for the severe architectural constraints of passive NFC SoCs. By emulating the dual-supply architecture and the 2 MHz clock limit of the Texas Instruments RF430FRL153H transponder, a continuous staircase voltage sweep is synthesized via pulsewidth modulation smoothed by a dual-stage, low-pass RC filter ($f_{c} = 10.24$ Hz). Faradaic currents are acquired using a transimpedance amplifier topology constrained to a 1.5 V digital window. Benchtop validation using a 5 mM potassium ferricyanide redox probe on screen-printed electrodes captured distinct faradaic signatures. The proposed AFE was benchmarked against a commercial laboratory-grade potentiostat, demonstrating comparable electrochemical sensitivity and a reversibility ratio ($Q_{a}/Q_{c} = 1.039 \pm 0.037$, $n=3$) closer to theoretical unity than the commercial reference ($0.766 \pm 0.026$). These results confirm the architectural feasibility of executing precise CV under the constraints of passive NFC SoCs, with integration onto the target RF-harvested platform reserved for future work.
无电池NFC循环伏安法的超低功耗模拟前端
通过可穿戴电化学传感器对生物标志物进行连续监测常常受到传统电池功率和外形因素的限制。无源近场通信(NFC)技术提供了一种高度可行的无电池替代方案;然而,由于缺乏专用硬件(如数模转换器),将复杂的电分析技术(如循环伏安法(CV))集成到超低功耗的片上系统(soc)中仍然是一个重大挑战。本文介绍了专为无源NFC soc的严格架构约束而定制的高保真、超低功耗模拟前端(AFE)的设计和约束仿真台式验证。通过模拟德克萨斯仪器RF430FRL153H应答器的双电源结构和2 MHz时钟限制,通过双级低通RC滤波器($f_{c} = 10.24$ Hz)平滑脉宽调制合成连续阶梯电压扫描。法拉第电流是通过一个限制在1.5 V数字窗口的跨阻放大器拓扑获得的。在屏幕印刷电极上使用5毫米铁氰化钾氧化还原探针进行台式验证,捕获了不同的法拉第特征。所提出的AFE以商业实验室级恒电位器为基准,显示出可比的电化学灵敏度和可逆性比($Q_{a}/Q_{c} = 1.039 \pm 0.037$, $n=3$)更接近理论统一,而不是商业参考($0.766 \pm 0.026$)。这些结果证实了在无源NFC soc约束下执行精确CV的架构可行性,并将集成到目标rf采集平台上,为未来的工作预留空间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Sensors Letters
IEEE Sensors Letters Engineering-Electrical and Electronic Engineering
CiteScore
3.50
自引率
7.10%
发文量
194
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书