{"title":"Ultra-Low-Power Analog Front-End for Batteryless NFC Cyclic Voltammetry","authors":"Matheus Willian Sprotte;Pedro Bertemes Filho","doi":"10.1109/LSENS.2026.3731448","DOIUrl":null,"url":null,"abstract":"The continuous monitoring of biomarkers via wearable electrochemical sensors is often hindered by the power and form-factor constraints of traditional batteries. Passive near-field communication (NFC) technologies offer a highly viable batteryless alternative; however, integrating complex electroanalytical techniques, such as cyclic voltammetry (CV), into ultra-low-power system-on-chips (SoCs) remains a significant challenge due to the lack of dedicated hardware like digital-to-analog converters. This letter presents the design and constraint-emulated benchtop validation of a high-fidelity, ultra-low-power analog front-end (AFE) tailored specifically for the severe architectural constraints of passive NFC SoCs. By emulating the dual-supply architecture and the 2 MHz clock limit of the Texas Instruments RF430FRL153H transponder, a continuous staircase voltage sweep is synthesized via pulsewidth modulation smoothed by a dual-stage, low-pass <italic>RC</i> filter (<inline-formula><tex-math>$f_{c} = 10.24$</tex-math></inline-formula> Hz). Faradaic currents are acquired using a transimpedance amplifier topology constrained to a 1.5 V digital window. Benchtop validation using a 5 mM potassium ferricyanide redox probe on screen-printed electrodes captured distinct faradaic signatures. The proposed AFE was benchmarked against a commercial laboratory-grade potentiostat, demonstrating comparable electrochemical sensitivity and a reversibility ratio (<inline-formula><tex-math>$Q_{a}/Q_{c} = 1.039 \\pm 0.037$</tex-math></inline-formula>, <inline-formula><tex-math>$n=3$</tex-math></inline-formula>) closer to theoretical unity than the commercial reference (<inline-formula><tex-math>$0.766 \\pm 0.026$</tex-math></inline-formula>). These results confirm the architectural feasibility of executing precise CV under the constraints of passive NFC SoCs, with integration onto the target RF-harvested platform reserved for future work.","PeriodicalId":13014,"journal":{"name":"IEEE Sensors Letters","volume":"10 11","pages":"4504304-4504304"},"PeriodicalIF":2.4000,"publicationDate":"2026-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=11680015","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Sensors Letters","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11680015/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/9/4 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
Abstract
The continuous monitoring of biomarkers via wearable electrochemical sensors is often hindered by the power and form-factor constraints of traditional batteries. Passive near-field communication (NFC) technologies offer a highly viable batteryless alternative; however, integrating complex electroanalytical techniques, such as cyclic voltammetry (CV), into ultra-low-power system-on-chips (SoCs) remains a significant challenge due to the lack of dedicated hardware like digital-to-analog converters. This letter presents the design and constraint-emulated benchtop validation of a high-fidelity, ultra-low-power analog front-end (AFE) tailored specifically for the severe architectural constraints of passive NFC SoCs. By emulating the dual-supply architecture and the 2 MHz clock limit of the Texas Instruments RF430FRL153H transponder, a continuous staircase voltage sweep is synthesized via pulsewidth modulation smoothed by a dual-stage, low-pass RC filter ($f_{c} = 10.24$ Hz). Faradaic currents are acquired using a transimpedance amplifier topology constrained to a 1.5 V digital window. Benchtop validation using a 5 mM potassium ferricyanide redox probe on screen-printed electrodes captured distinct faradaic signatures. The proposed AFE was benchmarked against a commercial laboratory-grade potentiostat, demonstrating comparable electrochemical sensitivity and a reversibility ratio ($Q_{a}/Q_{c} = 1.039 \pm 0.037$, $n=3$) closer to theoretical unity than the commercial reference ($0.766 \pm 0.026$). These results confirm the architectural feasibility of executing precise CV under the constraints of passive NFC SoCs, with integration onto the target RF-harvested platform reserved for future work.