Comparison of Cumulative Dissipated Energy Between Two Phacoemulsification Systems Using a Modified Flip-and-Chop Technique With Multidirectional Jerking Movement From a Phacoemulsification Handpiece.
{"title":"Comparison of Cumulative Dissipated Energy Between Two Phacoemulsification Systems Using a Modified Flip-and-Chop Technique With Multidirectional Jerking Movement From a Phacoemulsification Handpiece.","authors":"Ming Chen, Hung-Yuan Lin, Emily J Kang","doi":"10.7759/cureus.118645","DOIUrl":null,"url":null,"abstract":"<p><p>Introduction The four-dimensional Unity phacoemulsification tip is designed to optimize tip motion and reduce time and energy consumption in cataract surgery. This study highlights a modified flip-and-chop technique with an added multidirectional jerking motion to the phacoemulsification handpiece intraocularly (referred to as the \"five-dimensional flip-and-chop\") and compares the cumulative dissipated energy (CDE) between the four-dimensional Unity system (Alcon Inc., Geneva, Switzerland) and the torsional Centurion system (Alcon Inc., Geneva, Switzerland) under this technique. Methods This is a retrospective, sequential, non-randomized comparison of 40 consecutive cases of Centurion to 40 consecutive cases of Unity performed by a single surgeon at a single ambulatory surgical suite. The initial cataract density between the groups was compared using optical coherence tomography (OCT) image quality (IQ) values from a single Maestro 2 device (Topcon, Tokyo, Japan). Results The two groups had comparable mean ages, sex distributions, and IQs. The mean CDE was significantly lower in the Unity group (5.39; SD=2.8) than in the Centurion group (8.23; SD=5.9), with p=0.0075. Conclusion Utilizing the modified \"five-dimensional flip-and-chop\" technique, the four-dimensional Unity system produced significantly lower CDE than the torsional Centurion system. The addition of this technique to the phacoemulsification handpiece may further improve the efficiency of phacoemulsification.</p>","PeriodicalId":93960,"journal":{"name":"Cureus","volume":"18 10","pages":"e118645"},"PeriodicalIF":1.3000,"publicationDate":"2026-10-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13712403/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cureus","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7759/cureus.118645","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/10/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction The four-dimensional Unity phacoemulsification tip is designed to optimize tip motion and reduce time and energy consumption in cataract surgery. This study highlights a modified flip-and-chop technique with an added multidirectional jerking motion to the phacoemulsification handpiece intraocularly (referred to as the "five-dimensional flip-and-chop") and compares the cumulative dissipated energy (CDE) between the four-dimensional Unity system (Alcon Inc., Geneva, Switzerland) and the torsional Centurion system (Alcon Inc., Geneva, Switzerland) under this technique. Methods This is a retrospective, sequential, non-randomized comparison of 40 consecutive cases of Centurion to 40 consecutive cases of Unity performed by a single surgeon at a single ambulatory surgical suite. The initial cataract density between the groups was compared using optical coherence tomography (OCT) image quality (IQ) values from a single Maestro 2 device (Topcon, Tokyo, Japan). Results The two groups had comparable mean ages, sex distributions, and IQs. The mean CDE was significantly lower in the Unity group (5.39; SD=2.8) than in the Centurion group (8.23; SD=5.9), with p=0.0075. Conclusion Utilizing the modified "five-dimensional flip-and-chop" technique, the four-dimensional Unity system produced significantly lower CDE than the torsional Centurion system. The addition of this technique to the phacoemulsification handpiece may further improve the efficiency of phacoemulsification.