Diagnostic Accuracy of Computed Tomography for Radiographically Occult Scaphoid Fractures and Concordance With Magnetic Resonance Imaging: A Systematic Review.

IF 1.3 Q3 MEDICINE, GENERAL & INTERNAL
Cureus Pub Date : 2026-10-23 eCollection Date: 2026-10-01 DOI:10.7759/cureus.118468
Rohin Wong, Andrien Rajakumar, Arkar Lwin, Zina Al-Kaisy, Paul Defty-Wallace, Rashed Al-Khudairi
{"title":"Diagnostic Accuracy of Computed Tomography for Radiographically Occult Scaphoid Fractures and Concordance With Magnetic Resonance Imaging: A Systematic Review.","authors":"Rohin Wong, Andrien Rajakumar, Arkar Lwin, Zina Al-Kaisy, Paul Defty-Wallace, Rashed Al-Khudairi","doi":"10.7759/cureus.118468","DOIUrl":null,"url":null,"abstract":"<p><p>Scaphoid fractures are the most common carpal bone fracture. Non-union and avascular necrosis are complications of a missed fracture. Therefore, if plain radiographs are normal and symptoms persist, further imaging such as computed tomography (CT) or magnetic resonance imaging (MRI) are often performed. Previous systematic reviews have largely compared their diagnostic accuracy indirectly using separate patient cohorts. Our objective is to determine the diagnostic accuracy of CT for occult scaphoid fractures in patients who underwent both CT and MRI following a negative or equivocal initial radiograph, and to assess concordance between CT and MRI findings. A systematic review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. OVID MEDLINE, OVID Embase, and the Cochrane Library were searched for studies published from inception up to August 31, 2026. Eligible studies enrolled adults with clinically suspected scaphoid fracture and a negative or equivocal initial radiograph who subsequently underwent both CT and MRI. Risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2). Studies affected by partial verification or incorporation bias were excluded from quantitative synthesis. CT sensitivity and specificity were pooled using a bivariate random-effects model. Concordance between CT and MRI was reported using percentage agreement and Cohen's kappa. Eight studies met the inclusion criteria. Six studies contributed to the primary pooled analysis of CT diagnostic accuracy, with one study reporting two CT readers. Using the first reader data from that study, alongside the five other studies, pooled CT sensitivity was 79% (95% CI 61.5-89.8%) and specificity was 94.4% (95% CI 82.1-98.4%). A sensitivity analysis using the second reader produced a sensitivity of 69.2% (95% CI 48.0-84.6%), with an unchanged specificity of 94.4% (95% CI 85.5-98.0%). Three studies provided CT-MRI concordance data; two demonstrated almost perfect agreement, with Cohen's kappa values of 0.91. The dual-energy CT study demonstrated lower concordance. Three studies used a reference standard independent of both CT and MRI and demonstrated mixed comparative findings. Overall, one study was judged to have low risk of bias, and seven were high risk of bias. In the included studies, CT demonstrated high specificity but more limited sensitivity for occult scaphoid fracture in paired CT-MRI cohorts. These findings align with existing literature reviewing unpaired data sets. Therefore, the findings suggest that CT remains a relevant alternative to MRI, especially in centres where MRI is unavailable or contraindicated, or for surgical planning.</p>","PeriodicalId":93960,"journal":{"name":"Cureus","volume":"18 10","pages":"e118468"},"PeriodicalIF":1.3000,"publicationDate":"2026-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13694059/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cureus","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7759/cureus.118468","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/10/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Scaphoid fractures are the most common carpal bone fracture. Non-union and avascular necrosis are complications of a missed fracture. Therefore, if plain radiographs are normal and symptoms persist, further imaging such as computed tomography (CT) or magnetic resonance imaging (MRI) are often performed. Previous systematic reviews have largely compared their diagnostic accuracy indirectly using separate patient cohorts. Our objective is to determine the diagnostic accuracy of CT for occult scaphoid fractures in patients who underwent both CT and MRI following a negative or equivocal initial radiograph, and to assess concordance between CT and MRI findings. A systematic review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. OVID MEDLINE, OVID Embase, and the Cochrane Library were searched for studies published from inception up to August 31, 2026. Eligible studies enrolled adults with clinically suspected scaphoid fracture and a negative or equivocal initial radiograph who subsequently underwent both CT and MRI. Risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2). Studies affected by partial verification or incorporation bias were excluded from quantitative synthesis. CT sensitivity and specificity were pooled using a bivariate random-effects model. Concordance between CT and MRI was reported using percentage agreement and Cohen's kappa. Eight studies met the inclusion criteria. Six studies contributed to the primary pooled analysis of CT diagnostic accuracy, with one study reporting two CT readers. Using the first reader data from that study, alongside the five other studies, pooled CT sensitivity was 79% (95% CI 61.5-89.8%) and specificity was 94.4% (95% CI 82.1-98.4%). A sensitivity analysis using the second reader produced a sensitivity of 69.2% (95% CI 48.0-84.6%), with an unchanged specificity of 94.4% (95% CI 85.5-98.0%). Three studies provided CT-MRI concordance data; two demonstrated almost perfect agreement, with Cohen's kappa values of 0.91. The dual-energy CT study demonstrated lower concordance. Three studies used a reference standard independent of both CT and MRI and demonstrated mixed comparative findings. Overall, one study was judged to have low risk of bias, and seven were high risk of bias. In the included studies, CT demonstrated high specificity but more limited sensitivity for occult scaphoid fracture in paired CT-MRI cohorts. These findings align with existing literature reviewing unpaired data sets. Therefore, the findings suggest that CT remains a relevant alternative to MRI, especially in centres where MRI is unavailable or contraindicated, or for surgical planning.

计算机断层扫描诊断隐匿性舟状骨骨折的准确性及与磁共振成像的一致性:一项系统综述。
舟状骨骨折是最常见的腕骨骨折。骨折不愈合和无血管坏死是骨折未愈合的并发症。因此,如果x线平片正常且症状持续,则通常进行进一步的成像,如计算机断层扫描(CT)或磁共振成像(MRI)。以前的系统评价主要是使用单独的患者队列间接比较其诊断准确性。我们的目的是确定CT对隐匿性舟状骨骨折的诊断准确性,这些隐匿性舟状骨骨折患者在初始x线片阴性或不明确的情况下同时接受CT和MRI检查,并评估CT和MRI检查结果之间的一致性。按照系统评价和荟萃分析的首选报告项目(PRISMA)指南进行系统评价。OVID MEDLINE, OVID Embase和Cochrane Library检索了从成立到2026年8月31日发表的研究。符合条件的研究纳入了临床怀疑舟状骨骨折且初始x线片阴性或模棱两可的成年人,随后接受了CT和MRI检查。使用诊断准确性研究质量评估2 (QUADAS-2)评估偏倚风险。受部分验证或纳入偏倚影响的研究被排除在定量综合之外。采用双变量随机效应模型对CT的敏感性和特异性进行汇总。CT和MRI之间的一致性采用百分比一致性和Cohen’s kappa进行报告。8项研究符合纳入标准。六项研究对CT诊断准确性进行了初步汇总分析,其中一项研究报告了两个CT阅读器。使用来自该研究的第一个阅读器数据,以及其他五项研究,合并CT敏感性为79% (95% CI 61.5-89.8%),特异性为94.4% (95% CI 82.1-98.4%)。使用第二个阅读器进行敏感性分析,灵敏度为69.2% (95% CI 48.0-84.6%),特异性为94.4% (95% CI 85.5-98.0%)。三项研究提供了CT-MRI一致性数据;其中两个的kappa值几乎完全一致,Cohen的kappa值为0.91。双能CT检查显示低一致性。三项研究使用了独立于CT和MRI的参考标准,并显示了混合的比较结果。总的来说,一项研究被判定为低偏倚风险,七项研究被判定为高偏倚风险。在纳入的研究中,CT在配对CT- mri队列中显示出对隐匿性舟状骨骨折的高特异性,但敏感性较有限。这些发现与现有文献回顾未配对数据集一致。因此,研究结果表明,CT仍然是MRI的相关替代方案,特别是在MRI不可用或禁忌的中心,或用于手术计划。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书