Open-Set Recognition of Fire Smoke from Four-Channel Optical Smoke Detector.

IF 4 3区 综合性期刊 Q2 CHEMISTRY, ANALYTICAL
Sensors Pub Date : 2026-10-19 DOI:10.3390/s26206606
Liangbo Li, Ming Zhu, Mengxue Lin, Jiahao Gao, Linsen Zhao, Maosen Wang
{"title":"Open-Set Recognition of Fire Smoke from Four-Channel Optical Smoke Detector.","authors":"Liangbo Li, Ming Zhu, Mengxue Lin, Jiahao Gao, Linsen Zhao, Maosen Wang","doi":"10.3390/s26206606","DOIUrl":null,"url":null,"abstract":"<p><p>In fire smoke detection, interference aerosols frequently cause false alarms for photoelectric smoke detectors. Conventional closed-set classification models trained on limited samples cannot reliably handle unknown aerosol types, which further leads to false and missed alarms. To address this issue, we propose FireOSR-Net, an open-set recognition network for fire smoke identification using the signals of a four-channel optical scattering detector, which integrates three modules. First, Conv1d-LSTM is used to extract features from dual-wavelength, dual-angle scattered signals. Next, the out-of-distribution detection module constructs an open boundary between known and unknown aerosols and generates pseudo-unknown features to enhance the detection capability for out-of-domain samples. Finally, the distance of all scattered intensity signals to both the fire and the non-fire domain is calculated, and fire and non-fire proximity scores are output to assess their risk propensity. Experiments are performed on eight-class aerosol data acquired with our self-developed four-channel detector, including six known and two unknown test categories. It achieves a peak F1-score of 0.95 on known samples, while unknown smoldering-wire smoke and oil fumes reach 96.29% fire proximity and 89.68% non-fire proximity correspondingly. Such results demonstrate FireOSR-Net's capacity for aerosol classification, out-of-domain detection and risk evaluation towards interpretable low-false-alarm fire sensing.</p>","PeriodicalId":21698,"journal":{"name":"Sensors","volume":"26 20","pages":""},"PeriodicalIF":4.0000,"publicationDate":"2026-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors","FirstCategoryId":"103","ListUrlMain":"https://doi.org/10.3390/s26206606","RegionNum":3,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

In fire smoke detection, interference aerosols frequently cause false alarms for photoelectric smoke detectors. Conventional closed-set classification models trained on limited samples cannot reliably handle unknown aerosol types, which further leads to false and missed alarms. To address this issue, we propose FireOSR-Net, an open-set recognition network for fire smoke identification using the signals of a four-channel optical scattering detector, which integrates three modules. First, Conv1d-LSTM is used to extract features from dual-wavelength, dual-angle scattered signals. Next, the out-of-distribution detection module constructs an open boundary between known and unknown aerosols and generates pseudo-unknown features to enhance the detection capability for out-of-domain samples. Finally, the distance of all scattered intensity signals to both the fire and the non-fire domain is calculated, and fire and non-fire proximity scores are output to assess their risk propensity. Experiments are performed on eight-class aerosol data acquired with our self-developed four-channel detector, including six known and two unknown test categories. It achieves a peak F1-score of 0.95 on known samples, while unknown smoldering-wire smoke and oil fumes reach 96.29% fire proximity and 89.68% non-fire proximity correspondingly. Such results demonstrate FireOSR-Net's capacity for aerosol classification, out-of-domain detection and risk evaluation towards interpretable low-false-alarm fire sensing.

四通道光学感烟探测器火灾烟雾的开集识别。
在火灾感烟探测中,干扰气溶胶经常导致光电感烟探测器误报。在有限样本上训练的传统闭集分类模型不能可靠地处理未知的气溶胶类型,这进一步导致误报和漏报。为了解决这个问题,我们提出了FireOSR-Net,这是一个使用四通道光散射探测器信号进行火灾烟雾识别的开放集识别网络,它集成了三个模块。首先,利用Conv1d-LSTM对双波长、双角度散射信号进行特征提取;其次,分布外检测模块构建已知和未知气溶胶之间的开放边界,并生成伪未知特征,增强对分布外样本的检测能力。最后,计算所有散射强度信号到火灾域和非火灾域的距离,输出火灾域和非火灾域的接近度得分,以评估其风险倾向。利用自主研制的四通道探测器采集的8类气溶胶数据进行了实验,其中包括6个已知测试类和2个未知测试类。已知样品的峰值f1得分为0.95,未知阴燃丝烟和油烟分别达到96.29%的火接近度和89.68%的非火接近度。这些结果证明了FireOSR-Net在气溶胶分类、域外检测和可解释低假警报火灾感知风险评估方面的能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Sensors
Sensors 工程技术-电化学
CiteScore
7.30
自引率
12.80%
发文量
8430
审稿时长
1.7 months
期刊介绍: Sensors (ISSN 1424-8220) provides an advanced forum for the science and technology of sensors and biosensors. It publishes reviews (including comprehensive reviews on the complete sensors products), regular research papers and short notes. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书