{"title":"Successful extravascular implantable cardioverter defibrillator implantation in a patient with ankylosing spondylitis and severe thoracic deformity: a case report.","authors":"Jia He, Qiming Liu, Zean Zhu, Zhenjiang Liu, Zhihong Wu","doi":"10.1093/ehjcr/ytag758","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Severe thoracic deformity in ankylosing spondylitis (AS) can complicate implantable cardioverter defibrillator (ICD) implantation and device selection. Substernal EV-ICD implantation requires careful anatomical assessment and individualized procedural planning.</p><p><strong>Case summary: </strong>A 57-year-old male with severe AS and dilated cardiomyopathy was referred for primary prevention ICD implantation. Given the high complication risks associated with conventional approaches, EV-ICD was selected. A tailored positioning strategy was employed to accommodate the thoracic deformity. Intraoperative resistance during substernal dissection was successfully overcome through meticulous re-dissection. Favourable intraoperative electrical parameters were obtained, including an R-wave sensing amplitude of 5.6 mV without P-wave oversensing and successful defibrillation at 30 J on the first attempt. At 6-month follow-up, device performance remained stable without sensing anomalies or inappropriate shocks.</p><p><strong>Discussion: </strong>This case demonstrates the technical feasibility of EV-ICD implantation in a carefully selected patient with severe AS-associated thoracic deformity. Preoperative CT assessment, tailored patient positioning, careful dissection, and surgical backup enabled successful implantation and stable device performance during 6 months of follow-up.</p>","PeriodicalId":11910,"journal":{"name":"European Heart Journal: Case Reports","volume":"10 10","pages":"ytag758"},"PeriodicalIF":0.7000,"publicationDate":"2026-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13690091/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Heart Journal: Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/ehjcr/ytag758","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/10/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Severe thoracic deformity in ankylosing spondylitis (AS) can complicate implantable cardioverter defibrillator (ICD) implantation and device selection. Substernal EV-ICD implantation requires careful anatomical assessment and individualized procedural planning.

Case summary: A 57-year-old male with severe AS and dilated cardiomyopathy was referred for primary prevention ICD implantation. Given the high complication risks associated with conventional approaches, EV-ICD was selected. A tailored positioning strategy was employed to accommodate the thoracic deformity. Intraoperative resistance during substernal dissection was successfully overcome through meticulous re-dissection. Favourable intraoperative electrical parameters were obtained, including an R-wave sensing amplitude of 5.6 mV without P-wave oversensing and successful defibrillation at 30 J on the first attempt. At 6-month follow-up, device performance remained stable without sensing anomalies or inappropriate shocks.

Discussion: This case demonstrates the technical feasibility of EV-ICD implantation in a carefully selected patient with severe AS-associated thoracic deformity. Preoperative CT assessment, tailored patient positioning, careful dissection, and surgical backup enabled successful implantation and stable device performance during 6 months of follow-up.

强直性脊柱炎合并严重胸椎畸形患者血管外植入式心律转复除颤器植入术成功1例。
背景:强直性脊柱炎(AS)患者严重的胸部畸形会使植入式心律转复除颤器(ICD)的植入和设备选择复杂化。胸骨下EV-ICD植入需要仔细的解剖评估和个性化的手术计划。病例总结:一名患有严重AS和扩张型心肌病的57岁男性被推荐进行一级预防ICD植入。考虑到常规入路并发症风险高,我们选择了EV-ICD。采用量身定制的定位策略来适应胸部畸形。通过细致的再剥离,成功克服了胸骨下剥离术中阻力。获得了良好的术中电参数,包括r波感应振幅为5.6 mV,无p波过度感应,第一次尝试时30 J成功除颤。在6个月的随访中,设备性能保持稳定,没有感觉到异常或不适当的冲击。讨论:本病例证明了在精心挑选的严重as相关胸部畸形患者中植入EV-ICD的技术可行性。术前CT评估、量身定制的患者体位、仔细的解剖和手术备份使植入成功,并在6个月的随访中稳定了装置的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
European Heart Journal: Case Reports
European Heart Journal: Case Reports Medicine-Cardiology and Cardiovascular Medicine
CiteScore
1.30
自引率
10.00%
发文量
451
审稿时长
14 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书