Early Axial Length Response Predicts Long-Term Myopia Control in Children Undergoing Orthokeratology.

IF 2.4
Jacinto Santodomingo-Rubido, César Villa-Collar
{"title":"Early Axial Length Response Predicts Long-Term Myopia Control in Children Undergoing Orthokeratology.","authors":"Jacinto Santodomingo-Rubido, César Villa-Collar","doi":"10.1007/s44402-026-00224-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate whether early axial length (AL) change after 6 months of orthokeratology (OK) wear serves as a clinically meaningful biomarker for predicting long-term myopia control after 2 years.</p><p><strong>Methods: </strong>This retrospective analysis included 101 children from a multicentre OK cohort who completed 24 months of follow‑up, with AL measured at baseline and at 6, 12, 18 and 24 months. Early AL shortening was defined as a ≥0.01 mm reduction after 6 months. Longitudinal AL change was assessed using linear mixed‑effects models. To evaluate predictive utility, separate logistic regression models were fitted using the 6-month AL change (ΔAL₆<sub>m</sub>) as a continuous predictor for two predefined AL outcome categories: favourable AL response (ΔAL₂₄<sub>m</sub> ≤ 0.30 mm) and poor AL response (>0.59 mm). Receiver operating characteristic (ROC)‑derived probability thresholds were obtained using Youden's J statistic. External validation was performed in an independent OK cohort of 69 Japanese children (138 eyes).</p><p><strong>Results: </strong>Fourteen children (13.9%) showed early AL shortening. Mixed‑effects modelling showed a significant time × shortening interaction (p < 0.001), with shorteners elongating by ∼0.006 mm/month versus ∼0.019 mm/month in non‑shorteners, yielding ∼0.33 mm less AL growth at 24 months. ΔAL₆<sub>m</sub> strongly predicted a favourable AL response (area under the curve (AUC) = 0.90, p < 0.001), with an optimal threshold p*=0.33 corresponding to ΔAL₆<sub>m</sub> ≈ +0.07 mm. ΔAL₆<sub>m</sub> also predicted a poor AL response (AUC = 0.86, p < 0.001), with p*=0.11 (ΔAL₆<sub>m</sub> ≈ +0.09 mm). External validation confirmed high AUCs (0.92 and 0.86) but revealed imperfect calibration, particularly for poor AL response.</p><p><strong>Conclusions: </strong>Early AL change after 6 months of OK wear is a useful biomarker for risk‑stratifying long‑term myopia control response. Children with ΔAL₆<sub>m</sub> ≤ 0.07 mm were much more likely to achieve a favourable AL response, whereas those with ΔAL₆<sub>m</sub> ≥ 0.09 mm had an elevated risk of poor AL response.</p>","PeriodicalId":520731,"journal":{"name":"Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)","volume":" ","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2026-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s44402-026-00224-y","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To evaluate whether early axial length (AL) change after 6 months of orthokeratology (OK) wear serves as a clinically meaningful biomarker for predicting long-term myopia control after 2 years.

Methods: This retrospective analysis included 101 children from a multicentre OK cohort who completed 24 months of follow‑up, with AL measured at baseline and at 6, 12, 18 and 24 months. Early AL shortening was defined as a ≥0.01 mm reduction after 6 months. Longitudinal AL change was assessed using linear mixed‑effects models. To evaluate predictive utility, separate logistic regression models were fitted using the 6-month AL change (ΔAL₆m) as a continuous predictor for two predefined AL outcome categories: favourable AL response (ΔAL₂₄m ≤ 0.30 mm) and poor AL response (>0.59 mm). Receiver operating characteristic (ROC)‑derived probability thresholds were obtained using Youden's J statistic. External validation was performed in an independent OK cohort of 69 Japanese children (138 eyes).

Results: Fourteen children (13.9%) showed early AL shortening. Mixed‑effects modelling showed a significant time × shortening interaction (p < 0.001), with shorteners elongating by ∼0.006 mm/month versus ∼0.019 mm/month in non‑shorteners, yielding ∼0.33 mm less AL growth at 24 months. ΔAL₆m strongly predicted a favourable AL response (area under the curve (AUC) = 0.90, p < 0.001), with an optimal threshold p*=0.33 corresponding to ΔAL₆m ≈ +0.07 mm. ΔAL₆m also predicted a poor AL response (AUC = 0.86, p < 0.001), with p*=0.11 (ΔAL₆m ≈ +0.09 mm). External validation confirmed high AUCs (0.92 and 0.86) but revealed imperfect calibration, particularly for poor AL response.

Conclusions: Early AL change after 6 months of OK wear is a useful biomarker for risk‑stratifying long‑term myopia control response. Children with ΔAL₆m ≤ 0.07 mm were much more likely to achieve a favourable AL response, whereas those with ΔAL₆m ≥ 0.09 mm had an elevated risk of poor AL response.

早期眼轴长度反应预测接受角膜塑形手术儿童的长期近视控制。
目的:评价角膜塑形镜(OK)配戴6个月后早期眼轴长(AL)变化是否可作为预测2年后长期近视控制的有临床意义的生物标志物。方法:本回顾性分析包括101名来自多中心OK队列的儿童,他们完成了24个月的随访,在基线和6、12、18和24个月时测量AL。早期AL缩短定义为6个月后AL缩短≥0.01 mm。使用线性混合效应模型评估纵向AL变化。为了评估预测效用,使用6个月AL变化(ΔAL₆m)作为两个预定义AL结果类别的连续预测因子,拟合了单独的逻辑回归模型:AL反应良好(ΔAL₂₄m≤0.30 mm)和AL反应不良(>0.59 mm)。采用约登J统计量获得受试者工作特征(ROC)衍生的概率阈值。外部验证在69名日本儿童(138只眼睛)的独立OK队列中进行。结果:14例患儿(13.9%)出现早期AL缩短。混合效应模型显示显著的时间×缩短相互作用(p m强烈预测有利的AL响应)(曲线下面积(AUC) = 0.90, p m≈+0.07 mm)。ΔAL₆m预测AL响应较差(AUC = 0.86, p m≈+0.09 mm)。外部验证证实了较高的auc(0.92和0.86),但显示了不完善的校准,特别是差的AL反应。结论:佩戴OK眼镜6个月后早期AL变化是对长期近视控制反应进行风险分层的有用生物标志物。ΔAL₆m≤0.07 mm的儿童更有可能获得良好的AL反应,而ΔAL₆m≥0.09 mm的儿童AL反应不良的风险更高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书