Correlation Between Respiratory Blood Flow Velocity Variation and Dynamic Preload Variables During Coronary Artery Bypass Surgery: A Pilot Observational Study.

IF 2.6 4区 医学 Q2 ANESTHESIOLOGY
Adrian E Stephan, Christoph Lichtenstern, Markus A Weigand, Cornelius J Busch, Thorsten Brenner, Marcel Hochreiter
{"title":"Correlation Between Respiratory Blood Flow Velocity Variation and Dynamic Preload Variables During Coronary Artery Bypass Surgery: A Pilot Observational Study.","authors":"Adrian E Stephan, Christoph Lichtenstern, Markus A Weigand, Cornelius J Busch, Thorsten Brenner, Marcel Hochreiter","doi":"10.1053/j.jvca.2026.09.017","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To evaluate correlations between pressure-based dynamic preload indices and echocardiographic flow velocity variations during coronary artery bypass grafting (CABG).</p><p><strong>Design: </strong>Prospective observational pilot study.</p><p><strong>Setting: </strong>Single university hospital.</p><p><strong>Participants: </strong>Thirty adults undergoing elective CABG.</p><p><strong>Interventions: </strong>Modified passive leg raising (PLR) at 3 intraoperative time points.</p><p><strong>Measurements and main results: </strong>Mean arterial pressure increased after PLR at all 3 time points. In pooled analyses, stroke volume variation decreased from 13% ± 4% to 10% ± 4% and pulse pressure variation decreased from 10% ± 2% to 7% ± 3% (both p < 0.05). Respiratory peak velocity variations in the left ventricular outflow tract and descending aorta did not change significantly. Pulse contour-derived cardiac output also did not change (5.1 ± 1.1 L/min v 5.1 ± 1.1 L/min, p = 0.71). Stroke volume variation and pulse pressure variation correlated strongly (r = 0.720), whereas correlations between pressure- and flow-derived indices were weak (r = 0.147-0.351).</p><p><strong>Conclusions: </strong>Pressure-derived indices correlated only weakly with echocardiographic respiratory peak velocity variations in patients undergoing CABG. As forward flow did not measurably increase following modified PLR, the physiological significance of these weak correlations remains uncertain.</p>","PeriodicalId":15176,"journal":{"name":"Journal of cardiothoracic and vascular anesthesia","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2026-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of cardiothoracic and vascular anesthesia","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1053/j.jvca.2026.09.017","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To evaluate correlations between pressure-based dynamic preload indices and echocardiographic flow velocity variations during coronary artery bypass grafting (CABG).

Design: Prospective observational pilot study.

Setting: Single university hospital.

Participants: Thirty adults undergoing elective CABG.

Interventions: Modified passive leg raising (PLR) at 3 intraoperative time points.

Measurements and main results: Mean arterial pressure increased after PLR at all 3 time points. In pooled analyses, stroke volume variation decreased from 13% ± 4% to 10% ± 4% and pulse pressure variation decreased from 10% ± 2% to 7% ± 3% (both p < 0.05). Respiratory peak velocity variations in the left ventricular outflow tract and descending aorta did not change significantly. Pulse contour-derived cardiac output also did not change (5.1 ± 1.1 L/min v 5.1 ± 1.1 L/min, p = 0.71). Stroke volume variation and pulse pressure variation correlated strongly (r = 0.720), whereas correlations between pressure- and flow-derived indices were weak (r = 0.147-0.351).

Conclusions: Pressure-derived indices correlated only weakly with echocardiographic respiratory peak velocity variations in patients undergoing CABG. As forward flow did not measurably increase following modified PLR, the physiological significance of these weak correlations remains uncertain.

冠状动脉搭桥术中呼吸血流速度变化与动态预负荷变量的相关性:一项初步观察研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.80
自引率
17.90%
发文量
606
审稿时长
37 days
期刊介绍: The Journal of Cardiothoracic and Vascular Anesthesia is primarily aimed at anesthesiologists who deal with patients undergoing cardiac, thoracic or vascular surgical procedures. JCVA features a multidisciplinary approach, with contributions from cardiac, vascular and thoracic surgeons, cardiologists, and other related specialists. Emphasis is placed on rapid publication of clinically relevant material.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书