Guodong Weng, Piotr Radojewski, Sulaiman Sheriff, Arsany Hakim, Irena Zubak, Johannes Kaesmacher, Johannes Slotboom
{"title":"CHEmical-shift selective Adiabatic Pulse (CHEAP): fast and high resolution downfield 3D 1H-MRSI at 7T","authors":"Guodong Weng, Piotr Radojewski, Sulaiman Sheriff, Arsany Hakim, Irena Zubak, Johannes Kaesmacher, Johannes Slotboom","doi":"10.1016/j.jmr.2026.108185","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><div>The downfield resonances in the human brain remain elusive or challenging to detect with traditional <sup>1</sup>H-MRSI. Conventional <em>in vivo</em> 3D <sup>1</sup>H-MRSI faces several challenges, including low signal-to-noise ratio (SNR) and magnetization transfer effects with water, which can lead to prolonged measurement times and reduced spatial resolution. To address these limitations, we propose a downfield 3D-MRSI method aimed at measuring downfield metabolites with enhanced spatial resolution, and speed acceptable for clinical practice at 7T.</div></div><div><h3>Methods</h3><div>The <strong>CHE</strong>mical-shift selective <strong>A</strong>diabatic <strong>P</strong>ulse (CHEAP) technique was integrated into echo-planar spectroscopic imaging (EPSI) readout sequence for downfield metabolite and water reference 3D-MRSI. Five healthy subjects and two glioma patients were scanned to test the feasibility.</div></div><div><h3>Results</h3><div>In this work, CHEAP-EPSI technique achieves a high spatial resolution of 0.37 ml with a 10.5-min scan time. Its distinct advantages include relative insensitivity to transmit <em>B</em><sub><em>1</em></sub><sup><em>+</em></sup> inhomogeneity through adiabatic refocusing, effective suppression of water and lipid signals, and minimal baseline distortions, making it a valuable tool for research or potentially diagnostic purposes.</div></div><div><h3>Conclusions</h3><div>CHEAP-EPSI allows the rapid mapping of multiple downfield metabolites such as <em>N</em>-acetyl-aspartate (DF7.82) and DF8.18, and offers new possibilities for the study of metabolism in healthy and diseased brain.</div></div>","PeriodicalId":16267,"journal":{"name":"Journal of magnetic resonance","volume":"392 ","pages":"Article 108185"},"PeriodicalIF":2.1000,"publicationDate":"2026-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of magnetic resonance","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1090780726001758","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/10/16 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose
The downfield resonances in the human brain remain elusive or challenging to detect with traditional 1H-MRSI. Conventional in vivo 3D 1H-MRSI faces several challenges, including low signal-to-noise ratio (SNR) and magnetization transfer effects with water, which can lead to prolonged measurement times and reduced spatial resolution. To address these limitations, we propose a downfield 3D-MRSI method aimed at measuring downfield metabolites with enhanced spatial resolution, and speed acceptable for clinical practice at 7T.
Methods
The CHEmical-shift selective Adiabatic Pulse (CHEAP) technique was integrated into echo-planar spectroscopic imaging (EPSI) readout sequence for downfield metabolite and water reference 3D-MRSI. Five healthy subjects and two glioma patients were scanned to test the feasibility.
Results
In this work, CHEAP-EPSI technique achieves a high spatial resolution of 0.37 ml with a 10.5-min scan time. Its distinct advantages include relative insensitivity to transmit B1+ inhomogeneity through adiabatic refocusing, effective suppression of water and lipid signals, and minimal baseline distortions, making it a valuable tool for research or potentially diagnostic purposes.
Conclusions
CHEAP-EPSI allows the rapid mapping of multiple downfield metabolites such as N-acetyl-aspartate (DF7.82) and DF8.18, and offers new possibilities for the study of metabolism in healthy and diseased brain.
期刊介绍:
The Journal of Magnetic Resonance presents original technical and scientific papers in all aspects of magnetic resonance, including nuclear magnetic resonance spectroscopy (NMR) of solids and liquids, electron spin/paramagnetic resonance (EPR), in vivo magnetic resonance imaging (MRI) and spectroscopy (MRS), nuclear quadrupole resonance (NQR) and magnetic resonance phenomena at nearly zero fields or in combination with optics. The Journal''s main aims include deepening the physical principles underlying all these spectroscopies, publishing significant theoretical and experimental results leading to spectral and spatial progress in these areas, and opening new MR-based applications in chemistry, biology and medicine. The Journal also seeks descriptions of novel apparatuses, new experimental protocols, and new procedures of data analysis and interpretation - including computational and quantum-mechanical methods - capable of advancing MR spectroscopy and imaging.