Asymmetric metaphyseal cones versus medial modular block augment with central cone for medial tibial defects : a biomechanical comparison in varying bone quality.

IF 5.5 2区 医学 Q2 CELL & TISSUE ENGINEERING
Yi Ren, Chloe E H Scott, Nick D Clement, Shuqiao Xie, Pankaj Pankaj
{"title":"Asymmetric metaphyseal cones versus medial modular block augment with central cone for medial tibial defects : a biomechanical comparison in varying bone quality.","authors":"Yi Ren, Chloe E H Scott, Nick D Clement, Shuqiao Xie, Pankaj Pankaj","doi":"10.1302/2046-3758.1510.BJR-2026-0180.R1","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>Managing large medial tibial bone defects during total knee arthroplasty (TKA) remains technically demanding, particularly in elderly patients. This study quantitatively compares two reconstructive strategies: 'bridging' the defect using an asymmetric metaphyseal cone versus 'anatomical reconstruction' employing a symmetrical cone with a metallic block augment, and assesses their sensitivity to osteoporotic bone quality.</p><p><strong>Methods: </strong>A finite element model of a tibia with a standardized medial defect (Anderson Orthopaedic Research Institute (AORI) Type 2a) was adapted to simulate both configurations under physiological loading cycles in healthy and severe osteoporotic bone. Cumulative interface micromotion was quantified using a coordinate-based post-processing algorithm that decouples normal separation from tangential shear. A parametric sweep of the tangential contact clearance evaluated near-surface biological interaction zones without additional simulations.</p><p><strong>Results: </strong>In healthy bone, both strategies demonstrated adequate stability with micromotions predominantly below 50 μm. In osteoporotic bone, the asymmetric cone exhibited a loss of stability, characterized by intermittent lift-off during walking and excessive tangential shear during stair descending. This instability induced a toggle effect at the distal stem. The augmented symmetrical cone maintained stable fixation regardless of bone quality. Expanding the tangential contact clearance revealed considerable unrecognized shear risk surrounding the asymmetric cone, while the augmented construct remained insensitive to this parameter in the high-risk range (> 100 μm).</p><p><strong>Conclusion: </strong>Asymmetric cones are viable in good bone stock but exhibit instability in osteoporosis due to the cantilever effect. Anatomical reconstruction with a modular augment and central cone provides a predictable, load-sharing structural column, making it the preferred strategy for large medial defects in osteoporotic patients.</p>","PeriodicalId":9074,"journal":{"name":"Bone & Joint Research","volume":"15 10","pages":"1274-1287"},"PeriodicalIF":5.5000,"publicationDate":"2026-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13682064/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bone & Joint Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1302/2046-3758.1510.BJR-2026-0180.R1","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CELL & TISSUE ENGINEERING","Score":null,"Total":0}
引用次数: 0

Abstract

Aims: Managing large medial tibial bone defects during total knee arthroplasty (TKA) remains technically demanding, particularly in elderly patients. This study quantitatively compares two reconstructive strategies: 'bridging' the defect using an asymmetric metaphyseal cone versus 'anatomical reconstruction' employing a symmetrical cone with a metallic block augment, and assesses their sensitivity to osteoporotic bone quality.

Methods: A finite element model of a tibia with a standardized medial defect (Anderson Orthopaedic Research Institute (AORI) Type 2a) was adapted to simulate both configurations under physiological loading cycles in healthy and severe osteoporotic bone. Cumulative interface micromotion was quantified using a coordinate-based post-processing algorithm that decouples normal separation from tangential shear. A parametric sweep of the tangential contact clearance evaluated near-surface biological interaction zones without additional simulations.

Results: In healthy bone, both strategies demonstrated adequate stability with micromotions predominantly below 50 μm. In osteoporotic bone, the asymmetric cone exhibited a loss of stability, characterized by intermittent lift-off during walking and excessive tangential shear during stair descending. This instability induced a toggle effect at the distal stem. The augmented symmetrical cone maintained stable fixation regardless of bone quality. Expanding the tangential contact clearance revealed considerable unrecognized shear risk surrounding the asymmetric cone, while the augmented construct remained insensitive to this parameter in the high-risk range (> 100 μm).

Conclusion: Asymmetric cones are viable in good bone stock but exhibit instability in osteoporosis due to the cantilever effect. Anatomical reconstruction with a modular augment and central cone provides a predictable, load-sharing structural column, making it the preferred strategy for large medial defects in osteoporotic patients.

不对称干骺端锥体与内侧模块增强中央锥体治疗胫骨内侧缺损:不同骨质量的生物力学比较。
目的:在全膝关节置换术(TKA)中处理大胫骨内侧骨缺损仍然是技术上的要求,特别是在老年患者中。本研究定量比较了两种重建策略:使用不对称干骺端椎体“桥接”缺损与使用金属块增强的对称椎体“解剖重建”,并评估了它们对骨质疏松性骨质量的敏感性。方法:采用具有标准化内侧缺损的胫骨有限元模型(Anderson Orthopaedic Research Institute (AORI) Type 2a),模拟健康骨和严重骨质疏松骨在生理负荷循环下的两种构型。使用基于坐标的后处理算法对累积界面微运动进行量化,该算法将法向分离与切向剪切解耦。切向接触间隙的参数扫描评估了近地表生物相互作用区,没有额外的模拟。结果:在健康骨骼中,这两种策略都表现出足够的稳定性,微运动主要在50 μm以下。在骨质疏松症中,不对称椎体表现出稳定性的丧失,其特征是行走时间歇性的上升和下楼梯时过度的切向剪切。这种不稳定性在远端茎部诱发了扭扭效应。不论骨质量如何,增强型对称椎体均能保持稳定的固定。扩大切向接触间隙揭示了非对称锥体周围相当大的未识别剪切风险,而增强结构在高风险范围内(> 100 μm)对该参数不敏感。结论:非对称锥体在良好的骨源中是可行的,但在骨质疏松症中由于悬臂效应而表现出不稳定性。模块化增强和中心锥体的解剖重建提供了一个可预测的,负载共享的结构柱,使其成为骨质疏松症患者的大内侧缺陷的首选策略。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Bone & Joint Research
Bone & Joint Research CELL & TISSUE ENGINEERING-ORTHOPEDICS
CiteScore
7.40
自引率
23.90%
发文量
156
审稿时长
12 weeks
期刊介绍: The gold open access journal for the musculoskeletal sciences. Included in PubMed and available in PubMed Central.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书