Interindividual Variability in Temperature Rise From Localized Exposure at 1--80 GHz Using 131 Anatomical Head Models

IF 5.2 1区 工程技术 Q2 ENGINEERING, ELECTRICAL & ELECTRONIC
Itsuki Komine;Essam A. Rashed;Sachiko Kodera
{"title":"Interindividual Variability in Temperature Rise From Localized Exposure at 1--80 GHz Using 131 Anatomical Head Models","authors":"Itsuki Komine;Essam A. Rashed;Sachiko Kodera","doi":"10.1109/TMTT.2026.3731163","DOIUrl":null,"url":null,"abstract":"International exposure guidelines specify the 10-g averaged specific absorption rate (SAR) below 6 GHz and absorbed power density (APD) above 6 GHz as basic restrictions for local exposure. However, quantitative data on interindividual variability in radio frequency (RF)-induced temperature rise remain limited. In this study, temperature rise in the human head was evaluated using 131 anatomical models exposed to near-field RF sources from 1 to 80 GHz. Electromagnetic fields (EMFs) were computed using the finite-difference time-domain (FDTD) method, and steady-state temperature rise was obtained from the bioheat transfer equation. A heating factor (HF), defined as the ratio of the spatial peak temperature rise to 10-g SAR or APD, was used to quantify the relationship between absorbed electromagnetic power and thermal response. Interindividual variability was substantially lower for APD-based HF than for SAR-based HF. The coefficient of variation (CV) remained within approximately 20% for SAR-based HF and below 5% for APD-based HF. Similar behavior was observed across different antenna-to-skin separation distances and skin perfusion conditions. These findings suggest that APD is a stable metric for assessing localized temperature rise above 6 GHz, with only limited influence of anatomical variability.","PeriodicalId":13272,"journal":{"name":"IEEE Transactions on Microwave Theory and Techniques","volume":"74 10","pages":"8811-8819"},"PeriodicalIF":5.2000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Microwave Theory and Techniques","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/11694182/","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/9/16 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

International exposure guidelines specify the 10-g averaged specific absorption rate (SAR) below 6 GHz and absorbed power density (APD) above 6 GHz as basic restrictions for local exposure. However, quantitative data on interindividual variability in radio frequency (RF)-induced temperature rise remain limited. In this study, temperature rise in the human head was evaluated using 131 anatomical models exposed to near-field RF sources from 1 to 80 GHz. Electromagnetic fields (EMFs) were computed using the finite-difference time-domain (FDTD) method, and steady-state temperature rise was obtained from the bioheat transfer equation. A heating factor (HF), defined as the ratio of the spatial peak temperature rise to 10-g SAR or APD, was used to quantify the relationship between absorbed electromagnetic power and thermal response. Interindividual variability was substantially lower for APD-based HF than for SAR-based HF. The coefficient of variation (CV) remained within approximately 20% for SAR-based HF and below 5% for APD-based HF. Similar behavior was observed across different antenna-to-skin separation distances and skin perfusion conditions. These findings suggest that APD is a stable metric for assessing localized temperature rise above 6 GHz, with only limited influence of anatomical variability.
使用131个解剖头部模型研究1- 80 GHz局部暴露引起的温升的个体间变异
国际暴露准则规定,低于6 GHz的10 g平均比吸收率(SAR)和高于6 GHz的吸收功率密度(APD)是局部暴露的基本限制。然而,射频(RF)引起的温度升高的个体间变异的定量数据仍然有限。在这项研究中,使用131个暴露于1至80 GHz近场射频源的解剖模型来评估人类头部的温升。利用时域有限差分法(FDTD)计算电磁场,由生物传热方程得到稳态温升。加热因子(HF)定义为空间峰值温升与10g SAR或APD的比值,用于量化吸收电磁功率与热响应的关系。基于apd的HF个体间变异性明显低于基于sar的HF。基于sar的HF变异系数(CV)保持在20%左右,而基于apd的HF则低于5%。在不同的天线-皮肤分离距离和皮肤灌注条件下观察到相似的行为。这些发现表明,APD是评估局部温度升高超过6 GHz的稳定指标,只有有限的解剖变异影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Transactions on Microwave Theory and Techniques
IEEE Transactions on Microwave Theory and Techniques 工程技术-工程:电子与电气
CiteScore
8.60
自引率
18.60%
发文量
486
审稿时长
6 months
期刊介绍: The IEEE Transactions on Microwave Theory and Techniques focuses on that part of engineering and theory associated with microwave/millimeter-wave components, devices, circuits, and systems involving the generation, modulation, demodulation, control, transmission, and detection of microwave signals. This includes scientific, technical, and industrial, activities. Microwave theory and techniques relates to electromagnetic waves usually in the frequency region between a few MHz and a THz; other spectral regions and wave types are included within the scope of the Society whenever basic microwave theory and techniques can yield useful results. Generally, this occurs in the theory of wave propagation in structures with dimensions comparable to a wavelength, and in the related techniques for analysis and design.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书