Mitral Transcatheter Edge-to-Edge Repair in a Challenging Anatomy With Deeply Implanted Self-Expanding Valve and Severe Mitral Annular Calcification: A Case Report
Muhammad Saad MD, Raviteja Guddeti MD, Nadia El-Hangouche MD, Santiago Garcia MD
{"title":"Mitral Transcatheter Edge-to-Edge Repair in a Challenging Anatomy With Deeply Implanted Self-Expanding Valve and Severe Mitral Annular Calcification: A Case Report","authors":"Muhammad Saad MD, Raviteja Guddeti MD, Nadia El-Hangouche MD, Santiago Garcia MD","doi":"10.1016/j.jscai.2026.105571","DOIUrl":null,"url":null,"abstract":"<div><div>Mitral transcatheter edge-to-edge repair (M-TEER) in the setting of prior transcatheter aortic valve replacement (TAVR) and severe mitral annular calcification (MAC) can pose procedural challenges. We describe the case of an 82-year-old woman with prior TAVR (29 mm EVOLUT FX+; Medtronic), P2 flail, and heavy circumferential MAC underwent M-TEER with the PASCAL Ace device (Edwards Lifesciences). This case illustrates that M-TEER can be performed safely and effectively in anatomies complicated by severe MAC and prior TAVR with careful preprocedural planning, intraprocedural imaging, and operator experience.</div></div>","PeriodicalId":73990,"journal":{"name":"Journal of the Society for Cardiovascular Angiography & Interventions","volume":"5 10","pages":"Article 105571"},"PeriodicalIF":0.0000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Society for Cardiovascular Angiography & Interventions","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772930326013189","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/13 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Mitral transcatheter edge-to-edge repair (M-TEER) in the setting of prior transcatheter aortic valve replacement (TAVR) and severe mitral annular calcification (MAC) can pose procedural challenges. We describe the case of an 82-year-old woman with prior TAVR (29 mm EVOLUT FX+; Medtronic), P2 flail, and heavy circumferential MAC underwent M-TEER with the PASCAL Ace device (Edwards Lifesciences). This case illustrates that M-TEER can be performed safely and effectively in anatomies complicated by severe MAC and prior TAVR with careful preprocedural planning, intraprocedural imaging, and operator experience.