Glycopyrronium bromide, formoterol fumarate dihydrate and their related compounds with UPLC/PDA-MS for simultaneous determination in pressurized metered-dose inhaler product.
{"title":"Glycopyrronium bromide, formoterol fumarate dihydrate and their related compounds with UPLC/PDA-MS for simultaneous determination in pressurized metered-dose inhaler product.","authors":"Serdar Seckin, Serap Saglik Aslan","doi":"10.1093/chromsci/bmag030","DOIUrl":null,"url":null,"abstract":"<p><p>An ultra-performance liquid chromatography (UPLC) technique with photodiode array-mass spectrometry (PDA-MS) detectors has been developed and validated for the determination of glycopyrronium bromide (GB), formoterol fumarate dihydrate (FFD) and their related substances in pressurized meter dose inhalers. This marks the first time the method has been implemented. Chromatographic analyses have been carried out on a UPLC system with a single quadrupole mass spectrometer (QDa) and a PDA detector. A C18 column has been used prior to the injection valve. The column temperature was set to 40°C. For each analysis, 1 μL of sample was injected at a flow rate of 0.1 mL/minute. The mobile phases used were A (0.5% formic acid in methanol) and B (0.5% formic acid in water). The total run time of the method was 30 minutes. The PDA detector was employed at 215 nm while the mass detector was set to extracted ion chromatography (XIC) mode. The range for detecting impurities of GB was found to be between 0.28 and 0.30 ng/mL, with a limits of 0.92-1.01 ng/mL for quantification. GB and FFD demonstrated linear accuracy. We studied the accuracy of related substances within the limit of quantification value range of corresponding impurities and up to 400% of the limit value. The method we used was linear, rapid, reproducible and accurate. Our proposed method is fast, linear, accurate and reproducible. The UPLC-MS method, which utilized QDa with XIC mode, was developed to ascertain the related substances and assay of GB and FFD.</p>","PeriodicalId":15430,"journal":{"name":"Journal of chromatographic science","volume":"64 9","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2026-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13677063/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of chromatographic science","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1093/chromsci/bmag030","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
An ultra-performance liquid chromatography (UPLC) technique with photodiode array-mass spectrometry (PDA-MS) detectors has been developed and validated for the determination of glycopyrronium bromide (GB), formoterol fumarate dihydrate (FFD) and their related substances in pressurized meter dose inhalers. This marks the first time the method has been implemented. Chromatographic analyses have been carried out on a UPLC system with a single quadrupole mass spectrometer (QDa) and a PDA detector. A C18 column has been used prior to the injection valve. The column temperature was set to 40°C. For each analysis, 1 μL of sample was injected at a flow rate of 0.1 mL/minute. The mobile phases used were A (0.5% formic acid in methanol) and B (0.5% formic acid in water). The total run time of the method was 30 minutes. The PDA detector was employed at 215 nm while the mass detector was set to extracted ion chromatography (XIC) mode. The range for detecting impurities of GB was found to be between 0.28 and 0.30 ng/mL, with a limits of 0.92-1.01 ng/mL for quantification. GB and FFD demonstrated linear accuracy. We studied the accuracy of related substances within the limit of quantification value range of corresponding impurities and up to 400% of the limit value. The method we used was linear, rapid, reproducible and accurate. Our proposed method is fast, linear, accurate and reproducible. The UPLC-MS method, which utilized QDa with XIC mode, was developed to ascertain the related substances and assay of GB and FFD.
期刊介绍:
The Journal of Chromatographic Science is devoted to the dissemination of information concerning all methods of chromatographic analysis. The standard manuscript is a description of recent original research that covers any or all phases of a specific separation problem, principle, or method. Manuscripts which have a high degree of novelty and fundamental significance to the field of separation science are particularly encouraged. It is expected the authors will clearly state in the Introduction how their method compares in some markedly new and improved way to previous published related methods. Analytical performance characteristics of new methods including sensitivity, tested limits of detection or quantification, accuracy, precision, and specificity should be provided. Manuscripts which describe a straightforward extension of a known analytical method or an application to a previously analyzed and/or uncomplicated sample matrix will not normally be reviewed favorably. Manuscripts in which mass spectrometry is the dominant analytical method and chromatography is of marked secondary importance may be declined.