Repeatability of interpolated corneal tomography maps in healthy and keratoconus corneas before and after crosslinking.

IF 3 3区 医学 Q1 OPHTHALMOLOGY
Anneli Fredriksson, Jad Hayek, Anders Behndig
{"title":"Repeatability of interpolated corneal tomography maps in healthy and keratoconus corneas before and after crosslinking.","authors":"Anneli Fredriksson, Jad Hayek, Anders Behndig","doi":"10.1111/aos.70245","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the repeatability of interpolated Pentacam HR elevation, densitometry and anterior chamber depth (ACD) map data before and after customized corneal crosslinking (CXL) in keratoconus (KC) and healthy eyes with low-grade myopia (MY), including effects of KC severity.</p><p><strong>Methods: </strong>Participants with progressive KC or stable MY treated with CXL were included from prospective studies. Eyes lacking complete 6- and 12-month follow-up or acceptable quality Pentacam HR examinations were excluded. Repeatability was assessed descriptively and using linear mixed-effects models (LMMs) across groups and visits. KC severity analyses used baseline maximum keratometry (K<sub>max</sub>), both continuously and categorically (KC high/low).</p><p><strong>Results: </strong>Ninety-five right eyes (36 KC, 59 MY) were included. Variability was generally low and greater in KC only in central elevation (anterior, p < 0.001; posterior, p = 0.001; LMM). Nevertheless, model-based limits for absolute differences between measurements, termed repeatability limits (RLs), did not exceed 1.66 μm (maximum visit-specific descriptive RL: 2.55 μm). Descriptive comparisons indicated greater KC variability overall, mixed 6-month changes and smaller group differences at 12 months, but LMMs showed no significant post-CXL repeatability changes. Selected parameters showed 4%-8% greater variability per 1-D increase in K<sub>max</sub>, and several elevation parameters and central ACD were more variable in KC high than KC low.</p><p><strong>Conclusion: </strong>Interpolated Pentacam HR maps were highly repeatable, with no significant post-CXL change. Variability appeared more strongly related to KC severity than diagnosis or visit. Subsequent derivation may contribute additional variability to conventional Pentacam parameters, particularly in more advanced KC.</p>","PeriodicalId":6915,"journal":{"name":"Acta Ophthalmologica","volume":" ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2026-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Ophthalmologica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/aos.70245","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To evaluate the repeatability of interpolated Pentacam HR elevation, densitometry and anterior chamber depth (ACD) map data before and after customized corneal crosslinking (CXL) in keratoconus (KC) and healthy eyes with low-grade myopia (MY), including effects of KC severity.

Methods: Participants with progressive KC or stable MY treated with CXL were included from prospective studies. Eyes lacking complete 6- and 12-month follow-up or acceptable quality Pentacam HR examinations were excluded. Repeatability was assessed descriptively and using linear mixed-effects models (LMMs) across groups and visits. KC severity analyses used baseline maximum keratometry (Kmax), both continuously and categorically (KC high/low).

Results: Ninety-five right eyes (36 KC, 59 MY) were included. Variability was generally low and greater in KC only in central elevation (anterior, p < 0.001; posterior, p = 0.001; LMM). Nevertheless, model-based limits for absolute differences between measurements, termed repeatability limits (RLs), did not exceed 1.66 μm (maximum visit-specific descriptive RL: 2.55 μm). Descriptive comparisons indicated greater KC variability overall, mixed 6-month changes and smaller group differences at 12 months, but LMMs showed no significant post-CXL repeatability changes. Selected parameters showed 4%-8% greater variability per 1-D increase in Kmax, and several elevation parameters and central ACD were more variable in KC high than KC low.

Conclusion: Interpolated Pentacam HR maps were highly repeatable, with no significant post-CXL change. Variability appeared more strongly related to KC severity than diagnosis or visit. Subsequent derivation may contribute additional variability to conventional Pentacam parameters, particularly in more advanced KC.

交联前后健康角膜和圆锥角膜内插角膜层析图的可重复性。
目的:评价自定义角膜交联(CXL)治疗圆锥角膜(KC)和健康低度数近视(MY)前后内插Pentacam HR升高、密度测定和前房深度(ACD)图谱数据的可重复性,包括KC严重程度的影响。方法:采用CXL治疗的进行性KC或稳定性MY患者纳入前瞻性研究。排除了缺乏完整的6个月和12个月随访或质量可接受的Pentacam HR检查的眼睛。描述性地评估重复性,并使用线性混合效应模型(lmm)跨组和访问。KC严重程度分析使用基线最大角膜测量(Kmax),包括连续和分类(KC高/低)。结果:共纳入右眼95只(左眼36只,右眼59只)。KC的变异性一般较低,只有在中央抬高(前抬高、最大抬高、几个抬高参数和中央ACD在KC高的地方比KC低的地方变化更大。结论:内插的Pentacam HR图谱重复性高,cxl后无明显变化。变异性似乎与KC严重程度的关系比诊断或就诊的关系更强。随后的推导可能会对传统的Pentacam参数产生额外的可变性,特别是在更高级的KC中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Acta Ophthalmologica
Acta Ophthalmologica 医学-眼科学
CiteScore
7.60
自引率
5.90%
发文量
433
审稿时长
6 months
期刊介绍: Acta Ophthalmologica is published on behalf of the Acta Ophthalmologica Scandinavica Foundation and is the official scientific publication of the following societies: The Danish Ophthalmological Society, The Finnish Ophthalmological Society, The Icelandic Ophthalmological Society, The Norwegian Ophthalmological Society and The Swedish Ophthalmological Society, and also the European Association for Vision and Eye Research (EVER). Acta Ophthalmologica publishes clinical and experimental original articles, reviews, editorials, educational photo essays (Diagnosis and Therapy in Ophthalmology), case reports and case series, letters to the editor and doctoral theses.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书