{"title":"Research on Quasi-in-Situ Calibration Method for Multi-Channel Mismatches in Beam Signal Processors","authors":"An Wang;Youming Deng;Xing Yang;Yongbin Leng","doi":"10.1109/TNS.2026.3730092","DOIUrl":null,"url":null,"abstract":"The multi-channel beam signal acquisition and processing system is a core component of beam position monitoring (BPM) systems and their related diagnostics in particle accelerators. Its channel mismatches directly affect the measurement accuracy of key parameters such as beam position, bunch length, and charge. To address the challenge that existing calibration methods struggle to achieve calibration results consistent with online operation, this article proposes a quasi-in-situ calibration method for multi-channel mismatches based on the beam signal itself. Using the quasi-periodic characteristic of the beam signal, this method employs equivalent-time sampling combined with a waveform reconstruction algorithm to reconstruct the complete waveform for each channel with sufficient time resolution. It precisely calibrates the amplitude gains, time delays, and DC offsets between channels, enabling a correction for the entire analog signal processing chain, including the beam pickups, the signal cables, and the analog front-end (FE) electronics. Numerical simulations are performed to systematically analyze the influence of channel mismatches on the measured beam parameters, and an experimental verification is conducted at Hefei Light Source II (HLS-II) storage ring. The results demonstrate that this method significantly enhances the channel matching of the BPM signal processors in the time and frequency domains, providing a practical and reliable quasi-in-situ calibration method for high-accuracy beam measurements.","PeriodicalId":13406,"journal":{"name":"IEEE Transactions on Nuclear Science","volume":"73 10","pages":"3800-3810"},"PeriodicalIF":2.4000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Nuclear Science","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/11677246/","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/9/3 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
Abstract
The multi-channel beam signal acquisition and processing system is a core component of beam position monitoring (BPM) systems and their related diagnostics in particle accelerators. Its channel mismatches directly affect the measurement accuracy of key parameters such as beam position, bunch length, and charge. To address the challenge that existing calibration methods struggle to achieve calibration results consistent with online operation, this article proposes a quasi-in-situ calibration method for multi-channel mismatches based on the beam signal itself. Using the quasi-periodic characteristic of the beam signal, this method employs equivalent-time sampling combined with a waveform reconstruction algorithm to reconstruct the complete waveform for each channel with sufficient time resolution. It precisely calibrates the amplitude gains, time delays, and DC offsets between channels, enabling a correction for the entire analog signal processing chain, including the beam pickups, the signal cables, and the analog front-end (FE) electronics. Numerical simulations are performed to systematically analyze the influence of channel mismatches on the measured beam parameters, and an experimental verification is conducted at Hefei Light Source II (HLS-II) storage ring. The results demonstrate that this method significantly enhances the channel matching of the BPM signal processors in the time and frequency domains, providing a practical and reliable quasi-in-situ calibration method for high-accuracy beam measurements.
期刊介绍:
The IEEE Transactions on Nuclear Science is a publication of the IEEE Nuclear and Plasma Sciences Society. It is viewed as the primary source of technical information in many of the areas it covers. As judged by JCR impact factor, TNS consistently ranks in the top five journals in the category of Nuclear Science & Technology. It has one of the higher immediacy indices, indicating that the information it publishes is viewed as timely, and has a relatively long citation half-life, indicating that the published information also is viewed as valuable for a number of years.
The IEEE Transactions on Nuclear Science is published bimonthly. Its scope includes all aspects of the theory and application of nuclear science and engineering. It focuses on instrumentation for the detection and measurement of ionizing radiation; particle accelerators and their controls; nuclear medicine and its application; effects of radiation on materials, components, and systems; reactor instrumentation and controls; and measurement of radiation in space.