A Low-Cost Monocular Video-Based Framework for Bilateral Plantar Load Estimation During Treadmill Walking.

IF 4 3区 综合性期刊 Q2 CHEMISTRY, ANALYTICAL
Sensors Pub Date : 2026-10-06 DOI:10.3390/s26196307
Yanmei Jiao, Gan Huang, Xuan Huang, Yuan Bian, Bo Wu
{"title":"A Low-Cost Monocular Video-Based Framework for Bilateral Plantar Load Estimation During Treadmill Walking.","authors":"Yanmei Jiao, Gan Huang, Xuan Huang, Yuan Bian, Bo Wu","doi":"10.3390/s26196307","DOIUrl":null,"url":null,"abstract":"<p><p>Plantar load is an important biomechanical measure in gait analysis, rehabilitation assessment, and human movement evaluation. However, conventional measurement systems, including instrumented insoles and laboratory-based force measurement devices, rely on dedicated sensing hardware and may limit the accessibility of continuous gait monitoring. This study proposes a low-cost, monocular video-based framework for estimating bilateral plantar loads from pose-derived biomechanical features. As an initial application setting, we focused on treadmill walking, where a stationary camera can capture repeated body motion under consistent recording conditions, allowing the relationship between video-derived biomechanical features and plantar loading to be investigated before extending the framework to more variable environments. Video and reference plantar-load data from 14 healthy adults during treadmill walking at 3 km/h were temporally aligned, yielding 50,464 frame-level observations. Body landmarks estimated using MediaPipe Pose were used to construct posture-related, motion-related, and short-term temporal features. Four machine-learning regressors were evaluated, with fold-specific Top-60 feature selection applied to the morphology-excluded feature configuration. ExtraTrees achieved the highest mean performance under blocked temporal five-fold cross-validation, with R2 values of 0.762 ± 0.068 and 0.772 ± 0.073 for the left- and right-foot loads, respectively. Feature-group ablation showed that removing three static morphology variables had only a small effect on blocked-validation performance. Under zero-shot leave-one-subject-out validation, the corresponding mean R2 values were -0.252 ± 0.592 and -0.180 ± 0.573, indicating limited generalization to previously unseen participants. Using the initial 30 s of reference-load data for subject-specific supervised calibration improved prediction performance on the matched post-calibration interval. Regularized temporal, scale, and offset calibration increased the mean R2 values from -0.233 to 0.358 for the left-foot target and from -0.141 to 0.444 for the right-foot target. These findings demonstrate the potential of monocular video-derived biomechanical features for bilateral plantar-load estimation during controlled treadmill walking. Short supervised calibration improved average prediction performance for unseen participants, enabling subsequent video-based estimation without continuous wearable-sensor measurements.</p>","PeriodicalId":21698,"journal":{"name":"Sensors","volume":"26 19","pages":""},"PeriodicalIF":4.0000,"publicationDate":"2026-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13667742/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors","FirstCategoryId":"103","ListUrlMain":"https://doi.org/10.3390/s26196307","RegionNum":3,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Plantar load is an important biomechanical measure in gait analysis, rehabilitation assessment, and human movement evaluation. However, conventional measurement systems, including instrumented insoles and laboratory-based force measurement devices, rely on dedicated sensing hardware and may limit the accessibility of continuous gait monitoring. This study proposes a low-cost, monocular video-based framework for estimating bilateral plantar loads from pose-derived biomechanical features. As an initial application setting, we focused on treadmill walking, where a stationary camera can capture repeated body motion under consistent recording conditions, allowing the relationship between video-derived biomechanical features and plantar loading to be investigated before extending the framework to more variable environments. Video and reference plantar-load data from 14 healthy adults during treadmill walking at 3 km/h were temporally aligned, yielding 50,464 frame-level observations. Body landmarks estimated using MediaPipe Pose were used to construct posture-related, motion-related, and short-term temporal features. Four machine-learning regressors were evaluated, with fold-specific Top-60 feature selection applied to the morphology-excluded feature configuration. ExtraTrees achieved the highest mean performance under blocked temporal five-fold cross-validation, with R2 values of 0.762 ± 0.068 and 0.772 ± 0.073 for the left- and right-foot loads, respectively. Feature-group ablation showed that removing three static morphology variables had only a small effect on blocked-validation performance. Under zero-shot leave-one-subject-out validation, the corresponding mean R2 values were -0.252 ± 0.592 and -0.180 ± 0.573, indicating limited generalization to previously unseen participants. Using the initial 30 s of reference-load data for subject-specific supervised calibration improved prediction performance on the matched post-calibration interval. Regularized temporal, scale, and offset calibration increased the mean R2 values from -0.233 to 0.358 for the left-foot target and from -0.141 to 0.444 for the right-foot target. These findings demonstrate the potential of monocular video-derived biomechanical features for bilateral plantar-load estimation during controlled treadmill walking. Short supervised calibration improved average prediction performance for unseen participants, enabling subsequent video-based estimation without continuous wearable-sensor measurements.

一种低成本的基于单目视频的跑步机行走时双侧足底负荷估计框架。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Sensors
Sensors 工程技术-电化学
CiteScore
7.30
自引率
12.80%
发文量
8430
审稿时长
1.7 months
期刊介绍: Sensors (ISSN 1424-8220) provides an advanced forum for the science and technology of sensors and biosensors. It publishes reviews (including comprehensive reviews on the complete sensors products), regular research papers and short notes. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书