Channel-Specific Stimulus Sensitivity, Reliability, and Complementarity of Multimodal Wearable Sensing During Short-Form Influencer Video Exposure.

IF 4 3区 综合性期刊 Q2 CHEMISTRY, ANALYTICAL
Sensors Pub Date : 2026-10-08 DOI:10.3390/s26196354
Carolina Del-Valle-Soto, Violeta Corona, Regina Gómez Padilla, Fátima Sofía Walls Fernández, Juan-Carlos López-Pimentel, Carlos Mex-Perera, Paolo Visconti, José Varela-Aldás
{"title":"Channel-Specific Stimulus Sensitivity, Reliability, and Complementarity of Multimodal Wearable Sensing During Short-Form Influencer Video Exposure.","authors":"Carolina Del-Valle-Soto, Violeta Corona, Regina Gómez Padilla, Fátima Sofía Walls Fernández, Juan-Carlos López-Pimentel, Carlos Mex-Perera, Paolo Visconti, José Varela-Aldás","doi":"10.3390/s26196354","DOIUrl":null,"url":null,"abstract":"<p><p>Multimodal wearable sensing is increasingly used to quantify audience engagement with short-form video, yet it remains unclear which sensing channels actually carry stimulus-driven information at the exposure durations typical of this format. We recorded electrodermal activity, photoplethysmographic pulse, triaxial acceleration, video-based eye tracking, and automated facial expression analysis from 50 young adults while they viewed 20 short-form influencer clips (5.6-19.3 s) presented in individually randomized order, yielding 1000 participant × clip trials and 12 primary indices spanning four modalities. Using crossed random-effects variance partitioning, split-half reliability with Spearman-Brown projection, permutation-based multivariate testing, participant-wise decoding, and inter-subject correlation, we show that stimulus-driven variance is strongly channel-specific: it reaches 13.7% for fixation rate and 10.2% for facial engagement but only 0.11% for pulse rate and 0.23% for RMSSD. Clip-level estimates were highly reliable for facial and oculomotor indices (r=0.82-0.94) and poor for autonomic indices (r=0.34-0.58), which would require 134-370 participants to reach ρ=0.80. Between-modality dependence was almost six times weaker than within-modality dependence, and five components were retained by parallel analysis. Oculomotor and facial features jointly identified individual clips at 16.8% balanced accuracy against a 5% chance level, whereas electrodermal and pulse features, taken separately, did not exceed chance. Electrodermal responses were nonetheless stimulus-locked in 18 of 20 clips. A per-second re-analysis of nine channels showed that the ordering partly reverses for within-clip dynamics: tonic electrodermal and pupil time courses were reliable across viewers (ρ50=0.88 and 0.93), facial time courses were not (ρ50≤0.69), and pulse rate was unreliable under both treatments. We derive explicit design guidance for sensor selection and sample size in short-exposure multimodal engagement studies.</p>","PeriodicalId":21698,"journal":{"name":"Sensors","volume":"26 19","pages":""},"PeriodicalIF":4.0000,"publicationDate":"2026-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13667562/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors","FirstCategoryId":"103","ListUrlMain":"https://doi.org/10.3390/s26196354","RegionNum":3,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Multimodal wearable sensing is increasingly used to quantify audience engagement with short-form video, yet it remains unclear which sensing channels actually carry stimulus-driven information at the exposure durations typical of this format. We recorded electrodermal activity, photoplethysmographic pulse, triaxial acceleration, video-based eye tracking, and automated facial expression analysis from 50 young adults while they viewed 20 short-form influencer clips (5.6-19.3 s) presented in individually randomized order, yielding 1000 participant × clip trials and 12 primary indices spanning four modalities. Using crossed random-effects variance partitioning, split-half reliability with Spearman-Brown projection, permutation-based multivariate testing, participant-wise decoding, and inter-subject correlation, we show that stimulus-driven variance is strongly channel-specific: it reaches 13.7% for fixation rate and 10.2% for facial engagement but only 0.11% for pulse rate and 0.23% for RMSSD. Clip-level estimates were highly reliable for facial and oculomotor indices (r=0.82-0.94) and poor for autonomic indices (r=0.34-0.58), which would require 134-370 participants to reach ρ=0.80. Between-modality dependence was almost six times weaker than within-modality dependence, and five components were retained by parallel analysis. Oculomotor and facial features jointly identified individual clips at 16.8% balanced accuracy against a 5% chance level, whereas electrodermal and pulse features, taken separately, did not exceed chance. Electrodermal responses were nonetheless stimulus-locked in 18 of 20 clips. A per-second re-analysis of nine channels showed that the ordering partly reverses for within-clip dynamics: tonic electrodermal and pupil time courses were reliable across viewers (ρ50=0.88 and 0.93), facial time courses were not (ρ50≤0.69), and pulse rate was unreliable under both treatments. We derive explicit design guidance for sensor selection and sample size in short-exposure multimodal engagement studies.

短形式影响者视频曝光期间多模态可穿戴传感的通道特定刺激灵敏度、可靠性和互补性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Sensors
Sensors 工程技术-电化学
CiteScore
7.30
自引率
12.80%
发文量
8430
审稿时长
1.7 months
期刊介绍: Sensors (ISSN 1424-8220) provides an advanced forum for the science and technology of sensors and biosensors. It publishes reviews (including comprehensive reviews on the complete sensors products), regular research papers and short notes. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书