Andy Ho Wing Chan, Ryan C Emadi, Andy Lin, Mark J Schroeder, Ravinderjit Singh, Riaz Shaik, Mary-Catherine George, Jack Gomberg, Onome Eka, Toni Kavanagh, Ji Yeoun Jenna Yoo, Joanna C Jen, Ali Tajer, Anuradha Singh, Mijail Serruya, Achintya K Bhowmik, Muhammad A Parvaz
{"title":"A Pilot Study of the Feasibility of In-Ear EEG for Long-Term Temporal Lobe Brain Wave Monitoring.","authors":"Andy Ho Wing Chan, Ryan C Emadi, Andy Lin, Mark J Schroeder, Ravinderjit Singh, Riaz Shaik, Mary-Catherine George, Jack Gomberg, Onome Eka, Toni Kavanagh, Ji Yeoun Jenna Yoo, Joanna C Jen, Ali Tajer, Anuradha Singh, Mijail Serruya, Achintya K Bhowmik, Muhammad A Parvaz","doi":"10.3390/s26196343","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> Traditional scalp electroencephalography (EEG), though clinically validated, presents significant limitations, including lengthy setup, patient discomfort, and limited mobility. These factors hinder its utility for long-term ambulatory monitoring. In-ear EEG offers a promising alternative by leveraging the ear canal's anatomical proximity to the temporal lobes and natural mechanical stability. To address this, we developed SeizEAR, a standardized, three-size in-ear EEG system using paste-based electrodes with cross-ear referencing. <b>Methods:</b> This pilot study evaluated SeizEAR devices featuring small, medium, and large earpieces with superior and inferior paste-based electrodes in each ear, configured in a cross-ear reference scheme. It included five healthy adults who underwent recording sessions of approximately three hours (2.4 to 3.3 h). Electrode impedance was monitored against the acquisition system's threshold indicator, with simultaneous scalp EEG from T7/T8 electrodes serving as the reference. Participants rated comfort on a 0-5 Likert scale every 30 min. <b>Results:</b> In-ear recordings showed moderate, band-dependent correspondence with ipsilateral temporal scalp electrodes, strongest in the delta and alpha bands and weakest in beta, and correspondence was consistently higher against a geometrically matched T7-T8 bipolar derivation than against a single referenced electrode. In-ear alpha reactivity to eye closure was present but attenuated relative to scalp. Comfort ratings remained high over the final two hours of wear, with no reported adverse events. <b>Conclusions:</b> SeizEAR acquired in-ear EEG that corresponded moderately with temporal scalp EEG and was well-tolerated over multi-hour wear in healthy adults. These preliminary findings support further development of a standardized in-ear EEG system and require confirmation in an adequately powered sample.</p>","PeriodicalId":21698,"journal":{"name":"Sensors","volume":"26 19","pages":""},"PeriodicalIF":4.0000,"publicationDate":"2026-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13667745/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors","FirstCategoryId":"103","ListUrlMain":"https://doi.org/10.3390/s26196343","RegionNum":3,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Traditional scalp electroencephalography (EEG), though clinically validated, presents significant limitations, including lengthy setup, patient discomfort, and limited mobility. These factors hinder its utility for long-term ambulatory monitoring. In-ear EEG offers a promising alternative by leveraging the ear canal's anatomical proximity to the temporal lobes and natural mechanical stability. To address this, we developed SeizEAR, a standardized, three-size in-ear EEG system using paste-based electrodes with cross-ear referencing. Methods: This pilot study evaluated SeizEAR devices featuring small, medium, and large earpieces with superior and inferior paste-based electrodes in each ear, configured in a cross-ear reference scheme. It included five healthy adults who underwent recording sessions of approximately three hours (2.4 to 3.3 h). Electrode impedance was monitored against the acquisition system's threshold indicator, with simultaneous scalp EEG from T7/T8 electrodes serving as the reference. Participants rated comfort on a 0-5 Likert scale every 30 min. Results: In-ear recordings showed moderate, band-dependent correspondence with ipsilateral temporal scalp electrodes, strongest in the delta and alpha bands and weakest in beta, and correspondence was consistently higher against a geometrically matched T7-T8 bipolar derivation than against a single referenced electrode. In-ear alpha reactivity to eye closure was present but attenuated relative to scalp. Comfort ratings remained high over the final two hours of wear, with no reported adverse events. Conclusions: SeizEAR acquired in-ear EEG that corresponded moderately with temporal scalp EEG and was well-tolerated over multi-hour wear in healthy adults. These preliminary findings support further development of a standardized in-ear EEG system and require confirmation in an adequately powered sample.
期刊介绍:
Sensors (ISSN 1424-8220) provides an advanced forum for the science and technology of sensors and biosensors. It publishes reviews (including comprehensive reviews on the complete sensors products), regular research papers and short notes. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced.