{"title":"Ductility and lateral load performance of substandard RC columns retrofitted with CFRP over plastered Surface","authors":"Ali Gurkan Genc, Medine Ispir, Alper Ilki","doi":"10.1007/s10518-026-02540-7","DOIUrl":null,"url":null,"abstract":"<div><p>Seismic strengthening of existing reinforced concrete (RC) columns often involves applying carbon fiber-reinforced polymer (CFRP) jackets, which typically requires the removal of existing plaster layers to ensure direct bonding. While this practice is widely adopted, it increases construction costs, prolongs retrofit duration, generates considerable plaster waste, and may damage already low-strength concrete substrates. Previous experimental research has mainly focused on CFRP jackets applied directly to bare concrete, demonstrating their effectiveness in improving load-carrying capacity and ductility. However, the combined effects of plaster thickness, plaster strength, and CFRP jacket configuration on the seismic performance of square-section columns with retained plaster layers remain insufficiently explored. This study experimentally investigates the seismic performance of eight full-scale substandard RC columns (300 × 300 × 1350 mm) constructed with low-strength concrete (~10 MPa) and widely spaced transverse reinforcement, tested under reversed cyclic lateral loading while maintaining constant high axial load ratio of 60%. The experimental variables include three plaster thicknesses (12.5, 25, and 37.5 mm), two plaster compressive strengths (~3.5 and ~8.5 MPa), and single- or double-layer CFRP jackets. Test results demonstrate that retaining the plaster layer does not prevent significant ductility enhancement; in several cases, plastered CFRP-jacketed specimens achieved drift capacities comparable to or exceeding those of unplastered counterparts. These findings provide new experimental insights into the feasibility and effectiveness of CFRP jacketing over plastered concrete surfaces, highlighting a practical retrofitting approach that minimizes construction time, and environmental impact while maintaining structural performance.</p></div>","PeriodicalId":9364,"journal":{"name":"Bulletin of Earthquake Engineering","volume":"24 10","pages":"8489 - 8520"},"PeriodicalIF":4.2000,"publicationDate":"2026-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s10518-026-02540-7.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin of Earthquake Engineering","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s10518-026-02540-7","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, GEOLOGICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Seismic strengthening of existing reinforced concrete (RC) columns often involves applying carbon fiber-reinforced polymer (CFRP) jackets, which typically requires the removal of existing plaster layers to ensure direct bonding. While this practice is widely adopted, it increases construction costs, prolongs retrofit duration, generates considerable plaster waste, and may damage already low-strength concrete substrates. Previous experimental research has mainly focused on CFRP jackets applied directly to bare concrete, demonstrating their effectiveness in improving load-carrying capacity and ductility. However, the combined effects of plaster thickness, plaster strength, and CFRP jacket configuration on the seismic performance of square-section columns with retained plaster layers remain insufficiently explored. This study experimentally investigates the seismic performance of eight full-scale substandard RC columns (300 × 300 × 1350 mm) constructed with low-strength concrete (~10 MPa) and widely spaced transverse reinforcement, tested under reversed cyclic lateral loading while maintaining constant high axial load ratio of 60%. The experimental variables include three plaster thicknesses (12.5, 25, and 37.5 mm), two plaster compressive strengths (~3.5 and ~8.5 MPa), and single- or double-layer CFRP jackets. Test results demonstrate that retaining the plaster layer does not prevent significant ductility enhancement; in several cases, plastered CFRP-jacketed specimens achieved drift capacities comparable to or exceeding those of unplastered counterparts. These findings provide new experimental insights into the feasibility and effectiveness of CFRP jacketing over plastered concrete surfaces, highlighting a practical retrofitting approach that minimizes construction time, and environmental impact while maintaining structural performance.
期刊介绍:
Bulletin of Earthquake Engineering presents original, peer-reviewed papers on research related to the broad spectrum of earthquake engineering. The journal offers a forum for presentation and discussion of such matters as European damaging earthquakes, new developments in earthquake regulations, and national policies applied after major seismic events, including strengthening of existing buildings.
Coverage includes seismic hazard studies and methods for mitigation of risk; earthquake source mechanism and strong motion characterization and their use for engineering applications; geological and geotechnical site conditions under earthquake excitations; cyclic behavior of soils; analysis and design of earth structures and foundations under seismic conditions; zonation and microzonation methodologies; earthquake scenarios and vulnerability assessments; earthquake codes and improvements, and much more.
This is the Official Publication of the European Association for Earthquake Engineering.