Evaluating gamma-ray induced defect dynamics in HB-grade pencil graphite for radiotherapy-relevant dosimetry: an ESR and structural study

IF 3 4区 材料科学 Q3 MATERIALS SCIENCE, MULTIDISCIPLINARY
Duygu Ahi̇, Özgül Karataş
{"title":"Evaluating gamma-ray induced defect dynamics in HB-grade pencil graphite for radiotherapy-relevant dosimetry: an ESR and structural study","authors":"Duygu Ahi̇,&nbsp;Özgül Karataş","doi":"10.1007/s00339-026-10330-w","DOIUrl":null,"url":null,"abstract":"<div><p>The present work evaluates the dosimetric properties of commercial HB-grade pencil graphite (2 mm diameter) by analyzing radiation-induced paramagnetic defects in the radiotherapy-relevant dose range. For this purpose, HB pencil lead graphite was ground into a fine powder (20–100 μm) and then exposed to <sup>60</sup>Co gamma radiation at clinical radiotherapy levels ranging from 0 to 20 Gy. The structural and magnetic alterations were characterized using X-ray diffraction (XRD), Raman spectroscopy, scanning electron microscopy with energy-dispersive X-ray spectroscopy (SEM-EDS), and temperature-dependent X-band electron spin resonance (ESR) spectroscopy (20–300 K). XRD analysis confirmed the stability of the long-range graphitic lattice post-irradiation, while Raman spectroscopy showed evidence of radiation-induced structural disorder. ESR spectra exhibited a narrow Lorentzian signal, consistent with localized paramagnetic centers associated with the heterogeneous graphite-clay composite. Low-temperature ESR measurements revealed Curie-type paramagnetism, with line broadening at lower temperatures suggesting strong dipole-dipole interactions between localized spins. Additionally, gamma exposure induced systematic variations in both the ESR g-factor and spectral linewidth. Furthermore, a linear dose-response relationship was observed over the investigated dose range, with R² ≈ 0.99 between the ESR signal intensity and the absorbed gamma dose. Consequently, the investigated graphite-clay composite shows potential for further dosimetric investigation, provided that future studies address the native background and broader statistical validation.</p></div>","PeriodicalId":473,"journal":{"name":"Applied Physics A","volume":"132 11","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2026-10-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Physics A","FirstCategoryId":"4","ListUrlMain":"https://link.springer.com/article/10.1007/s00339-026-10330-w","RegionNum":4,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

The present work evaluates the dosimetric properties of commercial HB-grade pencil graphite (2 mm diameter) by analyzing radiation-induced paramagnetic defects in the radiotherapy-relevant dose range. For this purpose, HB pencil lead graphite was ground into a fine powder (20–100 μm) and then exposed to 60Co gamma radiation at clinical radiotherapy levels ranging from 0 to 20 Gy. The structural and magnetic alterations were characterized using X-ray diffraction (XRD), Raman spectroscopy, scanning electron microscopy with energy-dispersive X-ray spectroscopy (SEM-EDS), and temperature-dependent X-band electron spin resonance (ESR) spectroscopy (20–300 K). XRD analysis confirmed the stability of the long-range graphitic lattice post-irradiation, while Raman spectroscopy showed evidence of radiation-induced structural disorder. ESR spectra exhibited a narrow Lorentzian signal, consistent with localized paramagnetic centers associated with the heterogeneous graphite-clay composite. Low-temperature ESR measurements revealed Curie-type paramagnetism, with line broadening at lower temperatures suggesting strong dipole-dipole interactions between localized spins. Additionally, gamma exposure induced systematic variations in both the ESR g-factor and spectral linewidth. Furthermore, a linear dose-response relationship was observed over the investigated dose range, with R² ≈ 0.99 between the ESR signal intensity and the absorbed gamma dose. Consequently, the investigated graphite-clay composite shows potential for further dosimetric investigation, provided that future studies address the native background and broader statistical validation.

评估hb级铅笔石墨在放射治疗相关剂量学中的伽马射线诱导缺陷动力学:ESR和结构研究
本研究通过分析放射治疗相关剂量范围内的辐射诱导顺磁缺陷,评估了商用hb级铅笔石墨(2mm直径)的剂量学特性。为此,将HB铅笔芯石墨磨成细粉末(20 - 100 μm),然后暴露于60Co γ射线中,临床放疗水平为0至20 Gy。利用x射线衍射(XRD)、拉曼光谱(Raman spectroscopy)、扫描电子显微镜(SEM-EDS)和温度相关的x波段电子自旋共振(ESR)光谱(20-300 K)对其结构和磁性变化进行了表征。XRD分析证实了辐射后长程石墨晶格的稳定性,而拉曼光谱显示了辐射引起的结构紊乱的证据。ESR谱显示出窄的洛伦兹信号,与非均相石墨-粘土复合材料的局部顺磁中心一致。低温ESR测量显示出居里型顺磁性,在较低温度下谱线展宽表明局域自旋之间存在强烈的偶极子-偶极子相互作用。此外,伽马暴露诱导了ESR g因子和谱线宽度的系统变化。此外,在所研究的剂量范围内,ESR信号强度与吸收剂量之间呈线性关系,R²≈0.99。因此,所研究的石墨-粘土复合材料显示出进一步剂量学研究的潜力,前提是未来的研究解决本地背景和更广泛的统计验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Applied Physics A
Applied Physics A 工程技术-材料科学:综合
CiteScore
4.80
自引率
7.40%
发文量
964
审稿时长
38 days
期刊介绍: Applied Physics A publishes experimental and theoretical investigations in applied physics as regular articles, rapid communications, and invited papers. The distinguished 30-member Board of Editors reflects the interdisciplinary approach of the journal and ensures the highest quality of peer review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书