{"title":"EXPRESS: Diagnostic and prognostic value of on-site CT-derived fractional flow reserve in intracranial atherosclerotic stenosis.","authors":"Xinran Wang, Xuan Zeng, Jian Guo, Zhao Shi, Bin Hu, Li Lu, Bangjun Guo, Xiaoqing Cheng, Long Jiang Zhang","doi":"10.1177/0271678X261499068","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The role of CT-derived fractional flow reserve (CT-FFR) in cerebrovascular disease remains undefined. This study validated the diagnostic and prognostic value of an on-site CT-FFR in symptomatic intracranial atherosclerotic stenosis (sICAS) patients.</p><p><strong>Methods: </strong>This retrospective study enrolled sICAS patients with 30 - 99% stenosis confirmed by CTA, divided into two substudies. The diagnostic performance study included 259 patients undergoing CTA and CT perfusion (CTP) or four-dimensional CTA (CTP as reference standard). In prognosis study, 452 patients with at least 1-year follow-up were included. Computational fluid dynamics (CFD) model was used to measure CT-FFR. Diagnostic performance was assessed by receiver-operating characteristic (ROC) curves, and predictive value by Cox regression analysis.</p><p><strong>Results: </strong>The diagnostic performance of CT-FFR was significantly higher than diameter stenosis (DS) on both per-patient (P = 0.009) and per-lesion (P = 0.004) basis. And the cut-off value of CT-FFR diagnosing cerebral hypoperfusion was 0.80. 15.0% (68 / 452) patients experienced recurrent ischemic events during the median 24 (17-33) months follow-up. CT-FFR provided incremental prognostic value beyond traditional cardiovascular risks plus DS (AUC = 0.797 vs 0.716, P < 0.001).</p><p><strong>Conclusion: </strong>This on-site CT-FFR can serve as a valuable tool for diagnosis and risk stratification in sICAS patients.</p>","PeriodicalId":520660,"journal":{"name":"Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism","volume":" ","pages":"271678X261499068"},"PeriodicalIF":4.5000,"publicationDate":"2026-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/0271678X261499068","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Background: The role of CT-derived fractional flow reserve (CT-FFR) in cerebrovascular disease remains undefined. This study validated the diagnostic and prognostic value of an on-site CT-FFR in symptomatic intracranial atherosclerotic stenosis (sICAS) patients.
Methods: This retrospective study enrolled sICAS patients with 30 - 99% stenosis confirmed by CTA, divided into two substudies. The diagnostic performance study included 259 patients undergoing CTA and CT perfusion (CTP) or four-dimensional CTA (CTP as reference standard). In prognosis study, 452 patients with at least 1-year follow-up were included. Computational fluid dynamics (CFD) model was used to measure CT-FFR. Diagnostic performance was assessed by receiver-operating characteristic (ROC) curves, and predictive value by Cox regression analysis.
Results: The diagnostic performance of CT-FFR was significantly higher than diameter stenosis (DS) on both per-patient (P = 0.009) and per-lesion (P = 0.004) basis. And the cut-off value of CT-FFR diagnosing cerebral hypoperfusion was 0.80. 15.0% (68 / 452) patients experienced recurrent ischemic events during the median 24 (17-33) months follow-up. CT-FFR provided incremental prognostic value beyond traditional cardiovascular risks plus DS (AUC = 0.797 vs 0.716, P < 0.001).
Conclusion: This on-site CT-FFR can serve as a valuable tool for diagnosis and risk stratification in sICAS patients.